500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
UGCTE3S-X0 Panduit Corp Hook & Loop Cable Fastener; Cable Bundle Diameter Max:3; Cable Tie Width:0.85; Tensile Strength:50lb; Color:Black
MLT1S-CP Panduit Corp Cable Ties; Cable Bundle Diameter Max:1; Body Material:Nonmagnetic Stainless Steel; Tensile Strength:200lb; Pack Quantity:100
MLT4S-CP Panduit Corp Cable Ties; Cable Bundle Diameter Max:4; Body Material:Nonmagnetic Stainless Steel; Tensile Strength:200lb; Pack Quantity:100
UGCTC5S-X0 Panduit Corp Hook & Loop Cable Fastener; Cable Bundle Diameter Max:5; Cable Tie Width:0.85; Tensile Strength:50lb; Color:Black
MLT2H-LP Panduit Corp Cable Ties; Cable Bundle Diameter Max:2; Body Material:Nonmagnetic Stainless Steel; Tensile Strength:450lb; Pack Quantity:50
TMEH-X2-L0Y Panduit Corp Swivel Cable Tie Mount; Body Material:Nylon 6.6; Cable Tie Width:0.73; Tensile Strength:250lb; Color:Black

DIN EN 60352-2 tensile strength

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: permitted with 0,15mm maximum . Crimp tensile strength must comply with DIN EN 60352-2. 4.8 , 2.5 Standards For testing the crimp quality refer to DIN EN 60352-2. Rev B 2 of 7 , to DIN EN 60352-2 has to be performed. The End of the insulation must be visible in the transition , 114-18254-1 4.Requirements 4.1 Wire In general wires in accordance with DIN ISO 6722 Part 3 may be used Tyco Electronics
Original
DIN EN 60352-2 Tyco 408-7424 Application Specification 114-18022 408-7424 60352-2 EG00-0459-03
Abstract: retention force acc. DIN EN 60352-2 N 1.33-1.50 85 1.36-1.53 108 20 0.75 18 1.00 90 These min. values are based on the copper wire tensile strength with δB ≠230 N/mm 2 Amphenol
Original
Abstract: EN 60512 or DIN IEC 60512. IEC 60664-1 complies with DIN VDE 0110-1 â'¢ Prüfverfahren nach IEC 60512 entsprechen den Prüfverfahren nach DIN EN 60512 oder DIN IEC 60512. Die DIN IEC 60664-1 entspricht DIN VDE 0110-1 AnschluÃtechniken â'¢ Schraubverbindung Schraubklemmen werden nach EN 60999-1 , range of tensile strength for a screw connection with a clamp screw M3, fastened with a torque of 50 Ncm, depending on the wire size. Diagramm 1 Diagram 1 Tensile strength 50 6 Amphenol
Original
Abstract: voltage DIN EN 60664-11> 400 V 100V 100 V 4 X 320 V 12 x24 V Rated Impulse withstand voltage DIN EN 60664-11> 6000 V 3000 V 3000 V 4 x4000 V 12 x 800 V Pollution degree DIN EN 60664-11> 3 3 3 3 Installation (overvoltage) category DIN EN 60664-11> III III III III Material group DIN EN 60664-11> II II , < 5mQ Climatic Characteristics Climatic category DIN EN 60068-1 40 / 125 /56 40/100/56 , DIN EN 60529 IP 65 Insertion and withdrawal force DINEN 60512-13-2, test 13b < 25N < 30N < 22N -
OCR Scan
HN02016 C16-3 amphenol C016 10N017 0061 crimp lock nut torque value chart TN-02 025 0001 E63093 D-74080
Abstract: contacts 8 + PE 14 + PE 17 + PE 12 + 3 + PE Electrical Characteristics Rated voltage DIN EN , ) category Material group Current carrying capacity DIN EN 60664-1 DIN EN 60664-1 1) 1) 400 V 400 V 6000 , 4000 V, 12 x 800 V 3 III II 3 x 12 A, 12 x 6 A 3 x 10 A, 12 x 5 A DIN EN 60664-1 1) DIN EN 60664-1 1) DIN EN 60512-5-2, test 5b UL 1977, CSA 22.2 DIN EN 60512-3-1, test 3a DIN EN 60512-2-1, test 2a , technique Wire gauge / AWG Flammability Locking system 5 m DIN EN 60068-1 40 / 125 / 56 -40°C . -
Original
amphenol c16 10D008 DIN EN 60999-1 DIN EN 60352-2 contact resistance Amphetronix female connector Amphenol C16-3
Abstract: contacts 8 + PE 14 + PE 17 + PE 12 + 3 + PE Electrical Characteristics Rated voltage DIN EN , ) category Material group Current carrying capacity DIN EN 60664-1 DIN EN 60664-1 1) 1) 400 V 400 V 6000 , 4000 V, 12 x 800 V 3 III II 3 x 12 A, 12 x 6 A 3 x 10 A, 12 x 5 A DIN EN 60664-1 1) DIN EN 60664-1 1) DIN EN 60512-5-2, test 5b UL 1977, CSA 22.2 DIN EN 60512-3-1, test 3a DIN EN 60512-2-1, test 2a , technique Wire gauge / AWG Flammability Locking system 5 m DIN EN 60068-1 40 / 125 / 56 -40°C . Amphenol
Original
Abstract: 7 2-FRONT 2-FRONT 2-FRONT 2-FRONT DIN EN 60664-1 1) 750 V 900 V 400 V UL 1977, CSA 22.2 - - Rated impulse withstand voltage DIN EN 60664-1 1) 6000 V Pollution degree DIN EN 60664-1 1) Installation (overvoltage) category DIN EN 60664-1 1) Material group DIN EN 60664-1 1) Current carrying capacity at +55°C Rated voltage 100 V 3 x , x 250 V 10 x 400 V, 4 x 250 V 250 V Rated impulse withstand voltage DIN EN 60664-1 1 Amphenol
Original
C1023
Abstract: 0.14 up to 4 mm² Crimp Cross Section Tensile strength of crimped connections acc. to DIN IEC , VDE 0110 DIN EN 61 984 Frames Number of modules PE wire gauge - Power side - Signal side Material , ) Page 3 Technical Details Number of contacts Electrical data acc. to DIN EN 61 984 Rated current , Number of contacts Electrical data acc. to DIN EN 61 984 Rated current Rated voltage Rated impulse , Technical Details Number of contacts Electrical data acc. to DIN EN 61 984 Rated current Rated voltage HARTING
Original
MAGNUM METAL LOCATOR 09 67 000 9973 HARTING UpRight SP 37 12YC11Y M12-RJ HC 741 B-1731 NL-5234 NL-5203 N-0667
Abstract: hergestellten Crimpverbindungen entsprechen den in DIN EN 60352-2 bzw. IEC 60352-2 festgelegten Anforderungen , comply with the requirements and recommendations constituted by the DIN EN 60532-2 / IEC 60532-2. It is , einfaches Mittel zur Überwachung der Qualität einer Crimverbindung. 1000 Tensile strength of crimped , crimped connection by measuring the tensile strength is suggested. A=g eschlossene Crimphülse / closed , keep away mechanical stresses like vibrations, bending-, tensile-loads and loop strength from the crimp Amphenol
Original
calibration of crimping tools standards Connector Amphenol C164 Amphenol crimp tool locators Amphenol C164 amphenol C143 DIN EN 60352-2 exact crimping
Abstract: spring steel with a tensile strength of up to 2300 N/mm2 without damaging the tool. Bite cutting is , DIN EN 60352-2 and 60999-1. In addition to a variety of electrical and mechanical tests, conductor , according to DIN EN 60352-2 In practice, tractive forces can affect the crimping points during wiring or , 360 Minimum pull-out values for ferrules can be taken from DIN EN 60999-1. Gas-tight Gas , resistance of the contacts is recorded in accordance with DIN EN 60512-2-1:2002 before and after the Phoenix Contact
Original
3000-TOOLKIT
Abstract: , CSA, SEV, VDE Approvals UL, CSA, SEV, VDE Normen HN.D: DIN EN 175.301-801 Norms HN.D: DIN EN 175.301-801 Kontaktzahlen Number of contacts HN.D 7, 15, 25, 40, 50, 64, 80, 128 + , Reaction while on fire acc. to DIN EN 60707/VDE 0304 UL 94 V-0 ­ nonflammable, self extinguishing · Brandverhalten nach DIN EN 60707/VDE 0304 UL 94 V-0 ­ schwer entflammbar, selbstverlöschend · When burnt , Zulassungen · Markings for voltage, current and approvals · Brandverhalten nach DIN EN 60707/VDE 0304 Tyco Electronics
Original
female sockets thomas betts 14 pin CRITCHLEY ferrules DIN EN 60352-2 norm hsk 103 raychem TERMINATION CABLE 36 KV thomas betts male sockets 173/S
Abstract: und entsprechen im besonderen den Normen DIN EN 61984 (VDE 0627); IEC 60664-1 (VDE 0110-1) und IEC , with the standards DIN EN 61984 (VDE0627); IEC 60664-1 (VDE 0110-1) nad IEC 60529. The connectors may , A . 16 A · Anschlussart: crimpen · Kontaktdurchmesser 1,6 mm · Nach DIN EN 175 301 801 (DIN , Termination: crimp · Contact diameter 1,6 mm · According to DIN EN 175 301 801 (DIN 43652) · Number of , Bemessungsstrom 10 A . 16 A · Anschlussart: crimpen · Kontaktdurchmesser 1,6 mm · nach DIN EN 175 301-801 -
Original
Amphenol C146 din iec 60352 EN 175 301-801 japan tubes katalog d-sub backshell AMPHENOL circular connector 73/23/EWG
Abstract: und entsprechen im besonderen den Normen DIN EN 61984 (VDE 0627); IEC 60664-1 (VDE 0110-1) und IEC , with the standards DIN EN 61984 (VDE0627); IEC 60664-1 (VDE 0110-1) nad IEC 60529. The connectors may , Kontaktdurchmesser 1,6 mm · Nach DIN EN 175 301 801 (DIN 43652) · Polzahl: 7, 15, 25, 40, 50, 64, 128 · Rated , to DIN EN 175 301 801 (DIN 43652) · Number of contacts: 7, 15, 25, 40, 50, 64, 128 Serie C 146 DD , Bemessungsstrom 10 A . 16 A · Anschlussart: crimpen · Kontaktdurchmesser 1,6 mm · nach DIN EN 175 301-801 Amphenol-Tuchel Electronics
Original
TB cable lug catalogue VN02 016 0003 2 VN02 006 0015 EN 60352 C146 amphenol 91
Abstract: gefertigt und entsprechen im besonderen den Normen DIN EN 61984 (VDE 0627); IEC 60664-1 (VDE 0110-1) und IEC , Gerätesicherheitsgesetz (German law) and are especially in accordance with the standards DIN EN 61984 (VDE0627); IEC , Kontaktdurchmesser 1,6 mm · Nach DIN EN 175 301 801 (DIN 43652) · Polzahl: 7, 15, 25, 40, 50, 64, 128 · Polzahl: 24 , diameter 1,6 mm · According to DIN EN 175 301 801 (DIN 43652) · Number of contacts: 7, 15, 25, 40, 50, 64 , . 16 A · Anschlussart: crimpen · Kontaktdurchmesser 1,6 mm · nach DIN EN 175 301-801 (DIN 43652) · Amphenol-Tuchel Electronics
Original
131- AMPHENOL contact connector 16-pol pa gv CT53JF
Abstract: locking ring; screw locking according to DIN EN 60130-9 / IEC 60130-9 · Number of contacts: 2 ­ 8, 12 and , have to be tin-plated in the solder area. IEC 60 664 ^ DIN VDE 0110 ; IEC 60 512-x ^ DIN EN 60 512-x; IEC 60 130-9 ^ DIN EN 60 130-9 = = = 6 Amphenol C 091 A Male cable connector, screw , 3475 013 T 3475 038 T 3484 013 4) ­ ­ T 3504 013 ­ ­ ­ ­ Contact order for DIN EN 60 130-9 , remark page 6 3) T 3475 055 ­ Contact order for DIN EN 60 130-9 4) Available upon -
Original
DIN 4 PIN CIRCULAR PLASTIC CONNECTORS Amphenol Assembly instructions C091 31D005 100 2 U 3402 002 46 stereo 3.5mm socket 4 pole IEC connectors 130-9
Abstract: locking ring; screw locking according to DIN EN 60130-9 / IEC 60130-9 · Number of contacts: 2 ­ 8, 12 and , 60 512-x ^ = DIN EN 60 512-x; IEC 60 130-9 ^ = DIN EN 60 130-9 6 Amphenol C 091 A Male cable , .670) 17 (DIA.670) 17 (DIA.670) Contact order for DIN EN 60 130-9 Available upon request. 7 , DIN EN 60 130-9 6) Assembly instructions male cable connector, cable diameter 4-6 mm or 6-8 mm , .670) 17 (DIA.670) 17 (DIA.670) Contact order for DIN EN 60 130-9 Available upon request. 9 Amphenol
Original
5POL T 3437 902
Abstract: important for crimp connections. Tensile strength will be tested from HARTING as well in accordance to , , EN ISO 9001, the EU Eco-Audit and ISO 14001:2004 are America and Asia. The HARTING professionals , HARTING continuity at the same time. In securing this know-how laboratory (certified to EN 45001 , Information Technologies Mechatronic Ind Au to m ia ustr Ind B ac m Co mp Ven din , ergy Power Generati Wind En on an le A n tio lin sp ta or a S ol ergy r En HARTING
Original
AWM style 2789 VW-1 MO/21
Abstract: (DIN/IEC 60352-2) which are important for crimp connections. Tensile strength will be tested from , , certifications and audits. in telecommunications, applications in medical technology ­ EN ISO 9001, the EU , Production Technologies Ven din g HARTING s tr Simulation PCB Technologies Em , , the central HARTING laboratory (certified to EN 45001) provides simulation tools, as well as HARTING
Original
harting F-95972 Paris dsub 9 pole 4014 bp harting F-95972 Paris 9 pole Coaxial RJ 57 AWM 2789 .60 AWM 2651 28 awg D-32328
Abstract: contacts Housings are designed according to DIN EN 175 301 - 801 First-to-mate last-to-break , 7 15 25 40 50 64 2x25 â'¢ â'¢ â'¢ â'¢ DIN EN 175 301-801 (DIN 43652 , housings both protective earthing terminals shall be mounted. Standardised connectorsaccording to DIN ENâ'175 301 - 801 (DIN 43652) Interchangeable with all other products which are according to the Amphenol
Original
Abstract: contacts Housings are designed according to DIN EN 175 301 - 801 First-to-mate last-to-break , 15 25 40 64 50 2x25 â'¢ 7 â'¢ â'¢ â'¢ DIN EN 175 301-801 (DIN 43652 , housings both protective earthing terminals shall be mounted. Standardised connectorsaccording to DIN ENâ'175 301 - 801 (DIN 43652) Interchangeable with all other products which are according to the Amphenol
Original