500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
MSP430FW425IPM Texas Instruments 16-bit Ultra-Low-Power Microcontroller for Electronic Flow Meters 64-LQFP -40 to 85
MSP430FW423IPM Texas Instruments 16-bit Ultra-Low-Power Microcontroller for Electronic Flow Meters 64-LQFP -40 to 85
MSP430FW427IPM Texas Instruments 16-bit Ultra-Low-Power Microcontroller for Electronic Flow Meters 64-LQFP -40 to 85
MSP430FW427IPMR Texas Instruments 16-bit Ultra-Low-Power Microcontroller for Electronic Flow Meters 64-LQFP -40 to 85
MSP430FW425IPMR Texas Instruments 16-bit Ultra-Low-Power Microcontroller for Electronic Flow Meters 64-LQFP -40 to 85
MSP430FW423IPMR Texas Instruments 16-bit Ultra-Low-Power Microcontroller for Electronic Flow Meters 64-LQFP -40 to 85

"flow meter"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: expected flow rates through the meter fall within the accurate flow range of the meter. The meters flow range is defined as follows: Nominal flow rate Qn The designation flow rate of the meter. Maximum flow rate Qmax The highest flow rate at which the meter accuracy will be within the maximum permitted error. Minimum flow rate Qmin The lowest flow at which the meter accuracy will be within the maximum permitted error. Transitional flow rate Qt The flow rate at which the maximum permitted error of the meter changes RS Components
Original
turbine FLOW METER turbine orifice flow meter specifications qmax Turbine Flow meter water flow counter ISO4064
Abstract: LS Rotary Piston flow meter Model LS rotary piston flow meter (hereafter for short called flow meter) is a kind of volumetric flow-measuring instrument, mainly used to measure volume flow of liquid. Its clearest merit is suitability for measurement of rather little flow rate. This flow meter can , indicatingrecordingor controlling instruments. This flow meter has features as simple structure reliable , inspecting regulation is JJG 667-97 'for volumetric flow meter of liquid'. Principal Specifications Shanghai Automation Instrumentation
Original
XSJ-39 LS-15A LS-15B LS-25A SXP-3113 FLOW METER converter wiring pulse rate meter LYPR540AH DATASHEET XSF-40A
Abstract: Model LLQ Roots Flow meter for Gas LLQ Roots flow meter for gas (hereafter for short called flow meter) is a kind of volumetric flow meter used to measure volume flow of gas continuously passing , with the result that the rotor can be rotated flexibly and lightly. Thus this flow meter has the , velocity greatly changed. This flow meter has found wide application in measurements of wellhead natural gas, industrial coal gas, common gas and gas out of its generating station. This flow meter can Shanghai Automation Instrumentation
Original
pressure to current converter coal Gas Meter pulse rate meter circuit diagram 4-M12 pressure measuring instruments
Abstract: CMOSens® EM1 Mass Flow Meter for Gases - - - - - - - - CMOSens® technology Unbeatable , Summary The CMOSens® EM1 Mass Flow Meter (MFM) enables fast and economical measurement of gas flows over , ® EM1 Mass Flow Meter is suitable for a wide range of applications. Such include mass flow metering , measuring the gas flow and withstands overpressures of 8 bar (116 psi). The CMOSens® EM1 Mass Flow Meter , . EM1 is RoHS compliant. Figure 1: Block Diagram CMOSens® EM1 Mass Flow Meter. www.sensirion.com Sensirion
Original
CH-8712 int1200 air flow meter by micro controller staefa RS 50011-8100 STAEFA SPI EEPROM code flow diagram RS232 2002/96/EC 2002/95/EC
Abstract: CMOSens EM1 Mass Flow Meter for Gases - - - - - - - CMOSens technology Unbeatable price , Flow Meter (MFM) enables fast and economical measurement of gas flows over a very wide dynamic range , micro controller. Mounted in rugged, chemically inert housing the CMOSens EM1 Mass Flow Meter is , overpressures of 8 bar (116 psi). The CMOSens EM1 Mass Flow Meter requires a supply voltage of 7.18 Vdc and , Meter. www.sensirion.com Sensirion - the sensor company CMOSens EM1 Mass Flow Meter for Gases Sensirion
Original
energy meter circuit diagram mass flow meter sensor RS232 to parallel converter MOLEX 24 pin straight connector rs232 protocol air flow meter data sheet
Abstract: Model LB Scraper Flow Meter Model LB scraper flow meter is a kind of volumetric flow-measuring instrument, used to measure the volume flow in the enclosed pipes. This flow meter can provide on-site , pipe on upstream or downstream side of flow meter is its outstanding features. This flow meter is , regulation thereof is JJG 667-97 'for volumetric flow meter of liquid'. Principal Specifications Model , flow meter. Structure Diagram Scraper flow meter is principally composed of bodymeasuring -
Original
LB-250 LB-300 Wiring Diagram Great wall 12-M36 XSJ-39B gas oil LB-50 LB-80 LB-100 LB-150 LB-200
Abstract: LL-D Roots Flow Meter for Sandy Fluids Model LL-D roots flow meter is based on normal roots meter , crude oil containing sand or sand-like impurities. This flow meter can provide on-site display of , side of the flow meter. The standard for this flow meter is Q/YXBM 368-2000, while the inspecting regulation thereof is JJG 667-97 "Inspecting regulation of volumetric liquid flow meter". Principal , 120 0C, the flow meter should be purchased by special order. Model Designation Model Designation -
Original
LPJ 2 400 M16 bolt LPJ-12D LPJ-12D/FI XSJ-39A XSK-10B
Abstract: CMOSens® EM1 Mass Flow Meter for Gases â' â' â' â' â' â' â' â' CMOSens , The CMOSens® EM1 Mass Flow Meter (MFM) enables fast and economical measurement of gas flows over a , CMOSens® EM1 Mass Flow Meter is suitable for a wide range of applications. Such include mass flow , Flow Meter requires a supply voltage of 7-18 Vdc and provides an RS232 electrical interface. EM1 is RoHS compliant. no longer supported Figure 1: Block Diagram CMOSens® EM1 Mass Flow Meter Sensirion
Original
EM1NV
Abstract: directly proportional to the flow in a convenient form for processing. The PNF meter incorporates a rim , over the meter's linear flow range, improves the repeatability and extends the linear flow range , (when installed in conjunction with a meter prover) Minimum Linear Flow: is the minimum flow at , downstream pressure. Maximum Linear Flow: is the normal maximum continuous rating of meter. Response , located up to 500m from the turbine meter. 2 Extended Linear Flow: is an overspeed figure for -
Original
DIN 50049 turbine meter ABB KENT-TAYLOR 55 ABB KENT-TAYLOR digital Water Meter turbine flow meters
Abstract: CMOSens® EM1 Mass Flow Meter for Gases â' â' â' â' â' â' â' â' CMOSens , The CMOSens® EM1 Mass Flow Meter (MFM) enables fast and economical measurement of gas flows over a , CMOSens® EM1 Mass Flow Meter is suitable for a wide range of applications. Such include mass flow , Flow Meter requires a supply voltage of 7-18 Vdc and provides an RS232 electrical interface. EM1 is RoHS compliant. no longer supported Figure 1: Block Diagram CMOSens® EM1 Mass Flow Meter Sensirion
Original
Abstract: flow-captor smart meter C The adjustable flow meter Suitable for pipes up to 24" Measuring range from 0.2 m/s up to 2 m/s A flow meter for everything that flows Made for the 1/7th law , law. The flow-captor smart meter measures even very low flow rate due to the applied calorimetric principle. Small pipe diameter flow-captor smart meter Laminar flow is the ideal flow condition with , pipe diameter represents the average flow rate . Large pipe diameter flow-captor smart meter Captor
Original
D-25377 pt 4115 smart meter circuit diagram FLOW captor 4115.30 sensor Flow meter sensor for "water meter" Smart meter
Abstract: SLQ-QT105 Datasheet High Purity Milliliter Flow Meter for Hydrocarbons 1 Sensitive to low , monitoring Super fast sampling speed Product Summary The SLQ-QT105 Flow Meter offers an exceptional , In Table 1 the flow meter's performance for use with Isopropyl Alcohol (IPA) is given. For other , Media but Isopropyl Alcohol The flow meter's measurement performance for other media but Isopropyl , IPA, with the exception of the accuracy. The flow meter's calibration is only valid for IPA. For other Sensirion
Original
RS845 IPA sensor isopropyl alcohol sensor MICRO FLOW METER
Abstract: are clamped on the outside of the pipe at a specific distance from each other and the flow meter , Thermal Energy Meter For Permanent Installation How To Order The Flow Transducer: Please select one , MEASURE TODAY. ENSURE TOMORROW. ThermoProTM Series TP10 Ultrasonic Thermal Energy Meter For Permanent Installation Applications The TP10 thermal energy measurement meter is an ideal choice for a , for all commonly used pipes â'¢ Bi-directional flow measurement â'¢ Seamless integration of Spire Metering Technology
Original
ultrasonic sensor and application notes ultrasonic flow meter PT100 TP10-2-A-2-B-1-Y-1
Abstract: LL-C Roots Flow Meter for Light Oil Model LL-C roots flow meter as a kind of volumetric flow , 999999. By means of transmission output shaft, the flow meter could be coupled with photoelectron , control. This flow meter has features such as high measuring accuracycompact structurelight weighteasy , . Standard for this flow meter is Q/YXBM 368-2000; while the inspecting regulation thereof is JJG 667-97 , measuring cavity, a differential pressure will take place between the inlet and outlet of the flow meter Shanghai Automation Instrumentation
Original
LL-80C LL-50C LL-40C LL-100C 100C
Abstract: LL Roots Flow Meter Model LL Roots flow meter is a kind of volumetric instrument used to measure , downstream side of flow meter. It might be especially suitable for the fluids of high viscosity, and any change of viscosity should not cause obvious influence on the measured value. This flow meter should be , etc.) Standard for this flow meter is Q/YXBM 368-2000; while the inspecting regulation thereof is , differential pressure will take place between the inlet and outlet of flow meter. This pressure will force the -
Original
12-M30 12-M22 12-M27 16-M27 16-M30 16-M36
Abstract: Turbine Meter Model PTF Specification DataFile ss Wide flow range ­ up to 40:1 ss , Introduction Specification The new PTF meter offers exceptional flow range capability with good , the meter. Minimum Linear Flow ­ is the minimum flow at which the `k' factor (pulses per unit , Protection Box 10 or 20 x D Depending on meter size 5xD 5xD FLOW D Internal Dia 2.5D , flow rates from 0.4 to 284m3/h (1.46 to 1043 gal/min) ss Full chemical and mechanical material ABB Kent-Taylor
Original
MR-01-75 magnetic flow meter circuit diagram ultrasonic water flow meter magnetic flow meter ultrasonic flow meter circuit bs46
Abstract: Booster Pump Control Series 2100 Flow Monitor In larger systems, if the capacity of the first , systems must operate over a wide range of flow, but within a narrow band of pressure. Trying to match , forth. By ordering the Dual Channel Flow Monitor Model 2101, custom units can be created to monitor , a Badger Meter Applications Engineer. Analog Input Chart Recorder RS232/485 Modem Model 2100 4532087 2100 Series FLOW Monitor Optional Pressure Transducer Many booster pump Badger Meter
Original
109/B DAB-013-01
Abstract: User Guide ­ Sizing & Selection Software IM/OM/SW Issue 1 Compact Orifice Flow Meter , information. Compact Orifice Flow Meter OriMaster Contents Contents 1 Software Description , . 24 Issue 1 1 Compact Orifice Flow Meter OriMaster 1 Software Description 1 Software Description This software is the sizing and selection tool for the new ABB OriMaster flow meter. OriMaster is a compact orifice flow meter comprising an orifice carrier assembly, impulse piping, manifold ABB Automation
Original
ISO5167 ISO-5167 manual turbine flow meters ABB gas flow meter EN 10204 3.1 orifice selection for steam flow 9/90A
Abstract: User Guide IM/OMM Issue 2 Compact Orifice Flow Meter OriMaster M ABB The Company EN , , together with servicing and spares information. Compact Orifice Flow Meter OriMaster M Contents , . 16 Issue 2 1 Compact Orifice Flow Meter OriMaster M 1 General Safety Information , Issue 2 Compact Orifice Flow Meter OriMaster M 2 Installation 2 Installation 2.1 General , Sizing Table ­ Dimensions in mm (in.) 4 IM/OMM Issue 2 Compact Orifice Flow Meter OriMaster ABB Automation
Original
Orifice plate application of orifice plate CLASS 2500 VALVE PRESSURE CHART conductivity meter circuit climbing robot ABB EA 200
Abstract: Viscosity. Differential pressure measurement, across a laminar flow element, results in a flow meter that , flow detection allows the meter to measure extremely low flow rates at an affordable price. The FLR , system. Measurements are taken within the laminar region of the flow meter and the integral PID , . Water Flow Meter FLR-1601 FLR-1602 FLR-1614 FLR-1615 FLR-1603 FLR-1616 FLR-1604 FLR-1617 FLR , count would be 999999. Ordering Example: FLR-1601-I2-NIST, 1â"8" FNPT Water Flow Meter with optional Omega Engineering
Original
FLV-4600 FLR-1600 FMA-1600 FLV-1600 FMA1600-PS1 FMA1600-E1
Showing first 20 results.