500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : FINGERPRINT CLICK Supplier : MikroElektronika Manufacturer : TME Electronic Components Stock : 2 Best Price : $55.00 Price Each : $55.00
Shipping cost not included. Currency conversions are estimated. 

"finger probe"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: A AMP Power Series 50 FPR (Finger Probe Resistant) Connectors Revised 01/04 DESCRIPTION , 112355-1 KEY FEATURES · · · · Complies with UL 60950 finger probe requirements Utilizes 50 A AMP , · Designed to defeat UL finger probe as outlined in UL 60950 Contact Retention: 50 lbs. [222.4N , Power Series 50 FPR (Finger Probe Resistant) product is a new, novel extension to the standard AMP , product is designed to help prevent finger probe access and allows the product to be more safely used at Tyco Electronics
Original
E28476 finger probe Tyco amp connectors AMP CONNECTOR 5M-GIC-FP-01/04-0G3B
Abstract: application note, a grounded metal probe was used to simulate a finger during the data gathering experiments , measured at the receiver decreases when a grounded object, such as a finger, comes close to the induced , object touching the sensor is a finger or hand, which is naturally grounded. However, the size of the object touching the sensor is not constant; finger size can vary from person to person, or indeed the , need to be designed for a range of finger sizes, from small to large, to ensure that everyone can Analog Devices
Original
AN-830 AD7142 capacitive touch sensor pcb guideline sensor pcb capacitive touch slider Finger Sensor AN05849-0-12/05
Abstract: enhanced test probe due to one hand operation and push button (3 finger point). Insulated flexible shaft , 4 mm (.160 in) dia. springloaded plugs. Safety enhanced test probe due to one hand operation and push button (3 finger point). Insulated flexible shaft. Ratings: â'¢ Rated voltage , ) dia. springloaded plugs. Wide opening alligator clip. Safety enhanced test probe due to one hand operation and push button (3 finger point). 24.0222 Ratings: â'¢ Rated current -
OCR Scan
IEC1010
Abstract: Effective height P/N Description Status Y 0.8 2.0 0.3-0.5 1447009-5 Spring finger 0820 MP JP Box 1.7 2.0 0.8-1.3 1746136-1 Shield Finger 1720 MP JP Box 4 2.5 2.0-3.2 1734303-1 Shield Finger 4025 MP cage cage 1.2 0.95 0.65-1.1 1551631-4 Shield Finger 1295 I SH 1.5 1.1 0.95-1.3 1565158-1 Shield Finger 1511 MP JP cage 1.6 0.75 1.1-1.4 1565322-1 Shield Finger 1675 MP JP cage 1.8 Tyco Electronics
Original
SMIA 85 micro SD connector smd Micro USB IP 67 receptacle type TBA 129-5 connectors USB 2.0 3.5mm Jack CAMERA SMIA 85
Abstract: only suitable for use with in-line safety plugs. The probe features a molded finger guard which , Withdraw. Rated force current Contact resistance 4 mm Test probe with steel needle and 4 mm (.160 in) dia. in­ line safety socket, polyamide insulated. Test probe includes transparent protective , probe with steel needle and 4 mm (.160 in) dia. in­ line socket for spring-loaded 4 mm (.160 in) dia. plugs. Polyamide insulated. Test probe includes transparent protective cap SchK-SPP 4 -
OCR Scan
Abstract: . 5 4 Index Fingertip Placed Inside Finger Probe , LCD and PC · Finger probe off detection and display 1.2.2 MDK Hardware Several elements of the , front-end board Finger probe sensor VC5505 EVM RS232 Conn. (J13) RS232 Conn.(J13) Conn. Conn. J21 , connector on the pulse oximeter front-end board for connecting the finger probe. The front-end board amplifies and digitizes the signals received from the finger probe. ADC (ADS8328) on the front-end board is Texas Instruments
Original
spo2 circuit algorithm spo2 sensor diagram, spo2 sensor finger pulse oximeter pulse oximeter ir sensor oximeter circuit diagram SPRAB37 TMS320VC5505
Abstract: present indication'. Large finger guard to prevent accidental contact with live parts. Available with , ). 5 A Colors: 21,22 4 mm 1:3 - 5A Tast-D 66.926- Plug-on fused test probe , indication'. Large finger guard to prevent accidental contact with live parts. Colors: 21,22 4 mm - 16 A 0.8 m ft 66.9261 Fused probe lead, rated 500 V, CAT III, max. 16 A, have a fused test probe permanently attached to one end of a 1.5 m long, Silicone insulated, 1 mm2 cable with a 4mm -
OCR Scan
XPS-180 XPS-180/A XPS-18Q/A XSPS-200/A
Abstract: . Transparent fuse section for immediate 'fuse present indication'. Large finger guard to prevent accidental , 4 mm 1:3 - 5A Tast-D 66.9261 Plug-on fused test probe, rated 500 V, CAT III, max 5 , quick fuse changing. Transparent fuse section for immediate 'fuse present indication'. Large finger , £2 66.9267-15< Fused probe lead, rated 500 V, CAT III, max. 16 A, have a fused test probe permanently , - S 3 3 -« F Fused probe lead, rated 500 V, CAT III, max. 5 A, have -
OCR Scan
Abstract: AMP Power Series 50 FPR (Finger Probe Resistant) Connectors MATERIALS Contacts: Copper Housings: Polycarbonate, UL 94V-0 STANDARDS & SPECS â'¢ Component Recognized by UL to US & Canadian Standards, File No. E28476 â'¢ Complies with Finger Probe requirements of UL 60950 PRODUCT DIMENSIONS_ Housing P S3 id 1.38 2.20 ±.016 [55.98 ± 0.4] w .672 _ [17.08] PRODUCT OFFERING Housings Part Number Color 1604342-1 Brown 1604342-2 White Contacts - Cold-Headed Wire Size Part Number Loose Piece1 On Tape2 6AWG 647877-1 -
OCR Scan
5M-GIC-FP-03/04
Abstract: variations in jack spacing. · Polarizing: Handle notches identify location of each finger. · Tip Monitoring: Handle ports permit probe insertion to monitor tip circuits. · Terminating and Looping Plugs: OEMs can , in second plug.On special order, TT-Twin Plugs can be supplied with one 2-conductor finger and one 3-conductor finger. · Ease of Assembly/Disassembly: Refer to illustration below for assembly/disassembly procedure , back on metal lip on finger (inside notch) with small screwdriver and slip plug finger out of handle -
OCR Scan
p2240 Rod Resistors TT31 TT261 M642/13-3 P2240 P2642 T2318 T2319
Abstract: alligator clip. Safety enhanced test probe due to one hand operation and push button feature (3 finger , . springloaded plugs. Grips up to 4 mm (.160 in). Safety enhanced test probe due to one hand operation and push button feature (3 finger point). Insulated flexible shaft. 24.0221 Ratings: â'¢Rated voltage -
OCR Scan
Abstract: sure the retention finger is holding the contact. Spacer Retention Finger Circuit Cavity Seal Cover , cavity and deflect retention finger holding contact. Gently pull the wire until the contact is free from , the contact beams. Recommended probe design shown in Figure 9. 3.5. Reading Voltage During Service , troubleshooting to probe wires by piercing 1he insulation with a sharp point. This practice must be strongly , recommended continuity probe tip design, see Figure 9. 3.6. Header Assembly Printed Circuit (PC) Board -
OCR Scan
ECU "ford" ford eec-V eec-V ecu input and output ford electronic control unit ecu connectors I8DEC00
Abstract: in-line safety plugs. The probe features a molded finger guard which defines the lim it o f the safe , Withckaw. Rated force current Contact resistance 4 mm Test probe w ith steel needle and 4 mm (.160 in) dia. in­ line safety socket, polyamide insulated. Test probe includes transparent , mm 122 - u - -22.6 _9Z_ - Test probe w ith steel needle and 4 mm (.160 in) dia. in­ line socket fo r spring-loaded 4 mm (.160 in) dia. plugs. Polyamide insulated. Test probe -
OCR Scan
XPS-480/2G
Abstract: referred to as follows: · · Test Finger (Figure 9) Test Probe (Figure 9) The following sections , receptacle. FIGURE 10 TEST PROBE TEST FINGER 12.0 mm (Dia.) Copyright FCI Form E-3334 Rev F , specifications define three different probe designs to test for prevention of operator access to energized , . Although the HCI Power Connector System meets these probe requirements as noted, it is not recommended , . Du Power Connector System Mar 19 2010 CLASSIFICATION UNRESTRICTED 4.7.1 Test Finger -
Original
GS-20-070 xcede airMax EL-2008-02-008 GS-01-001 V08-0269 DG10-0108
Abstract: mains, as the user you are totally protected. No direct body/finger contact required to operate , bright LED gives clear to read indication from dim to bright conditions G Construction and finger , Finder Kit Contents TX 200UK £28.95 Receiver £36.00 IEC 2P IEC lead to probe or croc , Testers Fully Insulated - no finger contact G No finger contact to operate G Clearly , with Batteries (2 x CR 41 or similar) All features as NCT 0314 except finger contact required to Socket & See
Original
EN1010 ultrasonic distance meter A23 battery MT940 HD308 32A plug 60/TCN MT470 EN61010-1 EN61010-2-031
Abstract: SureGripTM Pincer Clip AC280 AC220 Multi-Form Teeth for Better Gripping Improved Finger Holds TL220 - , Flexible Resistant to Heat and Cold Superior Strain Relief TP220 - SureGripTM Industrial Test Probe Sharp, 1/2" Stainless Steel Tips for Improved Contact Flexible Finger Barrier Improves Grip Use with , Industrial Test Probe - EACH 66.95 23.95 15.95 - EACH 33.95 29.95 33.95 19.95 PASSIVE & ACTIVE Probes , TL970 TL75 TL71 TL175 ASSEMBLY TL40 Retractable Probes Retractable, Insulated Sharp Probe Tip CAT -
Original
TLK287 TLK289 TL910 TL950 tl-950 AC285 TP-220 TP920 TL940
Abstract: : Handle notches identify location of each finger. â'¢ Tip Monitoring; Handle ports permit probe insertion , plug.On special order, TT-Twin Plugs can be supplied with one 2-conductor finger and one 3-conductor finger. â'¢ Ease of Assembly/Disassembly: Refer to illustration below for assembly/disassembly , supplied with one. 2-conductor plug finger and one 3-conductor plug finger in the same handle (on special , . DISASSEMBLY: Place plug on edge as shown. Push down and back on metal lip on finger (inside notch) with small -
OCR Scan
TT253 TT254 TT250 TT700
Abstract: FINGER DESIGN" "COINED FINGER DESIGN" SAMTEC CORPORATION APPROVED BY: MAX PEEL PRESIDENT AND DIRECTOR , . The sample was positioned in such a manner so as to allow a special probe attached to a force transducer to deflect the contact element to a given distance as specified. The probe/force transducer is , ,&ntacts as tested are as follows: SPRING RATE 0.001 Deflection) a) b) cl 3. "Mill Max" "Skinny Finger , dimensions as measured were as follows: GAP (0 .OOO") m. "Mill Max" "Skinny Finger" "Coined" 0.0113 0.0104 Contech Research
Original
Abstract: substrate. DC and S-parameter measurements were conducted via probe station. S-parameters were measured in , at Vds=2V ang Vgs=-0.4V. TABLE I DEVICE GEOMETRIES Total Gate Width Gate Finger Number 0.4 mm , each device individually. The 60 W=0.4mm 40 20 0 5 10 15 20 25 Finger , (a) 60 0 (b) 5 10 15 20 25 Finger Number Fig. 3. Comparison between , 25 Finger Number Fig. 4. Cgd extracted with multi-device optimization. the multi-device -
Original
Abstract: ­ finger grip or slotted · shockproof according to IEC 529 test probe; live parts are completely , Finger grip or slotted fuse carriers available for most styles ­ ordered separately. Watertight and , , FBS / 83 · Pcb mount FPG / 84 · Finger grip or slotted fuse carriers available for most , start thread M 12.7 x 1.5 fixing nut SW 14 FPG bayonet fuse carrier ­ slotted or finger grip , request bayonet fuse carrier ­ slotted or finger grip solder terminals (end terminal 45° or 90 SCHURTER
Original
OGD 0031-8231 schurter fuse holder MXT 8211 A LR38456 FEC 031.1631 3101.8511
Showing first 20 results.