500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
WM8325GEFL/V Cirrus Logic Power Management Circuit, CMOS
WM8321GEFL/V Cirrus Logic Power Management Circuit, CMOS
WM8321GEFL/RV Cirrus Logic Power Management Circuit, CMOS
WM8325GEFL/RV Cirrus Logic Power Management Circuit, CMOS
WM8326GEFL/RV Cirrus Logic Power Supply Management Circuit, CMOS

"dynamic data manager"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: Dynamic Reconfiguration 3­3 Figure 3­3 shows page 3 of the ALTGX_RECONFIG MegaWizard Plug-In Manager , Reconfiguration chapter. Data rate division in TX-Allows dynamic reconfiguration of the transmitter , ALTGX_RECONFIG Megafunction User Guide Dynamic Reconfiguration Table 3­2. MegaWizard Plug-In Manager Options , Dynamic Reconfiguration Table 3­3. MegaWizard Plug-In Manager Options (Page 5) (Part 2 of 2 , ALTGX_RECONFIG MegaWizard Plug-In Manager" section of the Stratix IV Dynamic Reconfiguration chapter. Use Altera
Original
receiver dc offset estimate analog gain SIV53004-3
Abstract: megafunction. Start the MegaWizard Plug-In Manager using one of the following methods: Dynamic , example, dynamic reconfiguration from SONET to GIGE mode. Data rate division in TX ­ Allows dynamic , checked. "Dynamic Reconfiguration Setup in the MegaWizard Plug-In Manager" section in the Stratix , , Volume 2 Dynamic Reconfiguration Table 5­3. MegaWizard Plug-In Manager Options (Page 5) (Part 1 of , MegaWizard Plug-In Manager for the Dynamic Reconfiguration selection. Click Next. Figure 5­7. MegaWizard Altera
Original
SIIGX52006-1 RECONFIG
Abstract: Dynamic Reconfiguration Figure 3­2 shows the second page of the MegaWizard Plug-In Manager. Select the , Dynamic Reconfiguration 3­3 Figure 3­3 shows page 3 of the ALTGX_RECONFIG MegaWizard Plug-In Manager , Reconfiguration-Allows the dynamic reconfiguration of the CMU PLL to a different data rate. Channel and CMU PLL , option, the ALTGX_RECONFIG MegaWizard Plug-In Manager provides the error output port. The dynamic , ALTGX_RECONFIG MegaWizard Plug-In Manager" section of the HardCopy IV GX Dynamic Reconfiguration chapter in Altera
Original
HIV53003-1
Abstract: Dynamic Reconfiguration Figure 3­2 shows the second page of the MegaWizard Plug-In Manager. Select the , Dynamic Reconfiguration 3­3 Figure 3­3 shows page 3 of the ALTGX_RECONFIG MegaWizard Plug-In Manager , ALTGX_RECONFIG Megafunction User Guide Dynamic Reconfiguration 3­5 Table 3­1. MegaWizard Plug-In Manager , dynamic reconfiguration of the CMU PLL to a different data rate. Channel and CMU PLL , another data rate. Reference "Offset Cancellation" section of the HardCopy IV GX Dynamic Altera
Original
Abstract: megafunction. Start the MegaWizard Plug-In Manager using one of the following methods: Dynamic , Dynamic Reconfiguration Table 5­1. MegaWizard Plug-In Manager Options (Page 3) (Part 1 of 2 , switch within BASIC mode. For example, dynamic reconfiguration from SONET/SDH to GIGE mode. Data rate , Manager section in the Stratix II GX Dynamic Reconfiguration chapter in volume 2 of the Stratix II GX , Dynamic Reconfiguration Table 5­2. MegaWizard Plug-In Manager Options (Page 4) (Part 2 of 2 Altera
Original
Abstract: serial data rate. Based on the value you enter, the ALTGX MegaWizard Plug-In Manager populates the , frequency. Based on the value you enter, the ALTGX MegaWizard Plug-In Manager populates the data rate options in the What is the effective data rate? field. The ALTGX MegaWizard Plug-In Manager determines , , the ALTGX MegaWizard Plug-In Manager allows you to specify the effective serial data rate value in , effective data rate? field, the ALTGX MegaWizard Plug-In Manager determines the input reference clock Altera
Original
8B10B atx power supply schematic dc Chapter 3 Synchronization H146 OC48 sdi verilog code
Abstract: .15 3 Mechanics of the Common Security Services Manager (CSSM) Abstract The Common Data , Security Services Manager (CSSM) Introduction The Common Data Security Architecture (CDSA) is a set of , , integrity verification, and authorization checks during dynamic binding. Common Security Services Manager , 's elective module manager capability is a transparent mechanism supporting the dynamic addition of new , the Common Security Services Manager (CSSM) Transparent, Dynamic Attach Applications are not Intel
Original
signdata em reader module
Abstract: ® Plug-In Manager in the Quartus® II software creates or modifies design files that contain custom megafunction variations that can then be instantiated in a design file. The MegaWizard Plug-In Manager , MegaWizard to set the ALT2GXB megafunction features in the design. Start the MegaWizard Plug-In Manager using one of the following methods: Choose the MegaWizard Plug-In Manager command (Tools menu). When working in the Block Editor, click MegaWizard Plug-In Manager in the Symbol dialog box Altera
Original
diode handbook SDH 209 Stratix ii GX alt2gxb transistor DATA REFERENCE handbook transistors handbook SIIGX52003-4
Abstract: serial data rate. Based on the value you enter, the ALTGX MegaWizard Plug-In Manager populates the , frequency. Based on the value you enter, the ALTGX MegaWizard Plug-In Manager populates the data rate options in the What is the effective data rate? field. The ALTGX MegaWizard Plug-In Manager determines , , the ALTGX MegaWizard Plug-In Manager allows you to specify the effective serial data rate value in , effective data rate? field, the ALTGX MegaWizard Plug-In Manager determines the input reference clock Altera
Original
altgx vhdl code for deserializer VHDL Coding for Pulse Width Modulation SIV53001-4
Abstract: ® Plug-In Manager in the Quartus® II software creates or modifies design files that contain custom megafunction variations that can then be instantiated in a design file. The MegaWizard Plug-In Manager , to set the ALT2GXB megafunction features in the design. Start the MegaWizard Plug-In Manager using one of the following methods: Choose the MegaWizard Plug-In Manager command (Tools menu). When working in the Block Editor, click MegaWizard Plug-In Manager in the Symbol dialog box (Edit menu Altera
Original
alt2gxb gxb tx_coreclk texas handbook handbook
Abstract: Chapter" "Dynamic Reconfiguration Modes" on page 2­3 "Quartus II MegaWizard Plug-In Manager , MegaWizard Plug-In Manager" on page 2­139 "Combining Transceiver Channels with Dynamic , data rate switch However, the following dynamic reconfigurations cannot be achieved for the regular , classified into the following dynamic reconfiguration modes: Data rate division in TX Data rate , : HardCopy IV GX Dynamic Reconfiguration Quartus II MegaWizard Plug-In Manager Interfaces to Support Dynamic Altera
Original
HIV53002-1
Abstract: chapters: Chapter 3, Stratix II GX Dynamic Reconfiguration Chapter 4, Stratix II GX ALT2GXB , transceiver builds on the success of the Stratix GX family by offering higher data rate support and , (SERDES) data path through the transceiver and supports data rates from 600 Mbps to 3.125 Gbps. Double-width mode has a 16-bit/20-bit SERDES data path through the transceiver and supports data rates from 1 , multiplier unit (CMU) to provide clocking flexibility and support a range of incoming data streams. Each Altera
Original
CPRI multi rate digital alarm clock vhdl code vhdl code for 16 prbs generator HD-SDI over sdh 10 band graphic equalizer CEI 23-16 SIIGX52001-2 375-G
Abstract: dynamic reconfiguration controller instance generated by the ALTGX_RECONFIG MegaWizard Plug-In Manager , dynamic reconfiguration controller instance generated by the ALTPLL_RECONFIG MegaWizard Plug-In Manager , Manager [page 2a] AN 609: Implementing Dynamic Reconfiguration in Cyclone IV GX Devices © July 2010 , AN 609: Implementing Dynamic Reconfiguration in Cyclone IV GX Devices © July 2010 AN-609-1.0 Cyclone IV GX transceivers support the dynamic reconfiguration feature which provides a solution that Altera
Original
485G EP4CGX15 EP4CGX150 EP4CGX22 EP4CGX30 EP4CGX75
Abstract: dynamic reconfiguration controller instance generated by the ALTGX_RECONFIG MegaWizard Plug-In Manager , the ALTGX_RECONFIG MegaWizard Plug-In Manager. AN 558: Implementing Dynamic Reconfiguration in , tab of the ALTGX MegaWizard Plug-In Manager. AN 558: Implementing Dynamic Reconfiguration in Arria , : Implementing Dynamic Reconfiguration in Arria II GX Devices Page 28 Data Rate Division in TX Operation , ALTGX_RECONFIG MegaWizard Plug-In Manager. © July 2010 Altera Corporation AN 558: Implementing Dynamic Altera
Original
AN-558-3 tx 2G transmitter tx2/rx2
Abstract: checks/Data rate switch tab of the ALTGX_RECONFIG MegaWizard Plug-In Manager. This option is available , ALTGX_RECONFIG MegaWizard Plug-In Manager provides the error output port. The dynamic reconfiguration controller , Dynamic Reconfiguration in Arria II GX Devices Page 28 Data Rate Division in TX Operation Data , Plug-In Manager. Figure 21 shows a read transaction waveform in this mode. Figure 21. Data Rate Division , AN 558: Implementing Dynamic Reconfiguration in Arria II GX Devices © January 2010 AN Altera
Original
AN-558-2
Abstract: MegaWizard Plug-In Manager provides the list of input reference clock frequencies based on the data rate , architecture and dynamic reconfiguration for the HardCopy ® IV device family. This section includes the , Dynamic Reconfiguration Chapter 3, HardCopy IV GX ALTGX_RECONFIG Megafunction User Guide , sublayer (PCS) and physical medium attachment (PMA), at serial data rates between 600 Mbps and 6.5 Gbps. Up to 12 additional full-duplex CDR-based transceivers with PMA, supporting serial data rates Altera
Original
HIV53001-1 pcie Gen2 payload
Abstract: and data sharing. The MBX manager utilizes queues and semaphores and independent from the mailbox , DSP/BIOS II 15 SPRA675 Figure 11. Task Manager Properties To disable dynamic memory , 4.1 Global Settings (GBL Manager) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4.2 Idle Function Manager (IDL Manager) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4.3 Memory Manager (MEM Texas Instruments
Original
DSP/BIOS example code C5000 C6000 DSP/bios function call RTDX SPRA646
Abstract: . MegaWizard Plug-In Manager [page 3 of 8] Stage II: Enable Dynamic Reconfiguration in the ALTGX , Implementing Dynamic Reconfiguration in Cyclone IV GX Devices AN-609-2013.03.05 Application Note Cyclone® IV GX transceivers support the dynamic reconfiguration feature which provides a solution that allows you to dynamically reconfigure the transceiver channels to multiple protocols, data , and powering down the transceiver channels. This application note describes how to use the dynamic Altera
Original
Abstract: and data sharing. The MBX manager utilizes queues and semaphores and independent from the mailbox , . Task Manager Properties To disable dynamic memory allocation, right-click on the MEM ­ Memory Section , 4.1 Global Settings (GBL Manager) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4.2 Idle Function Manager (IDL Manager) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4.3 Memory Manager (MEM Texas Instruments
Original
bios function call bios function call definition Bios settings TMS320C6000
Abstract: serial data rate. Based on the value you enter, the ALTGX MegaWizard Plug-In Manager populates the , frequency. Based on the value you enter, the ALTGX MegaWizard Plug-In Manager populates the data rate options in the What is the effective data rate? field. The ALTGX MegaWizard Plug-In Manager determines , , the ALTGX MegaWizard Plug-In Manager allows you to specify the effective serial data rate value in , effective data rate? field, the ALTGX MegaWizard Plug-In Manager determines the input reference clock Altera
Original
altgx basic mode mode-10-bit