500 MILLION PARTS FROM 12000 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

"drop wire"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: Voltage Drop There is a reason we call him – Wire Wizard. Sam Friedman–“Wire , in USA For DC current, voltage drop is proportional to amount of current flow and wire resistance , the proper wire size for length of run to keep voltage drop at the desired level. To simplify your , challenging form of wire wizardry is new product development, followed closely by solving tough, often , Services, Carol® Brand Cord Products, and the entire team of General Cable Wire Wizards are ready to ... General Cable
Original
datasheet

2 pages,
197.06 Kb

TEXT
datasheet frame
Abstract: , and must not be used to form new listings. 99 Series 99 990 Series Electrical Type 2 3-wire DC 3 2-wire AC 6 2-wire DC Package Length A Standard 2 A A 12 A N ­ A2 IO & Modifications 22 gage 3-wire DC A2 2 m length A5 5 m length A10 10 m length 22 gage 2-wire AC or DC B2 2 m length B5 5 m length B10 10 m length 24 gage 3-wire DC (8 mm) C2 2 m length C5 , threaded Torson DC (8 mm) Output Type N NPN P PNP T 2 wire NO/NC A Normally Open B Normally ... Honeywell
Original
datasheet

7 pages,
949.53 Kb

992AA12AP-HD 993AA18AT-B2 992AB12AP-HD 992AA08AP-C2 992AB18BP-HD 803001A09M050 992AA12AP-A2 992AA08BP-C2 992AA12AN-A2 992AA18AN-HD 992AB18AN-A2 996AB12AT-B2 992AB12AP-A2 992aa30an-a2 992AB18AP-A2 992AA18AP-HD 992AA08AN-C2 996AA18AT-HD 992AA12AN-HD Honeywell 992AA12AP-A2 TEXT
datasheet frame
Abstract: have a patented voltage drop test, which applies a full 15 ampere load without causing interruption to equipment on the circuit. Product Features · Identifies and Locates Loose Wire Connections , Proper Wiring in 3-Wire Receptacles Proper GFCI Operation Dedicated Circuit Presence Isolated Ground , Drop by Conducting an Actual Full 15 Amp Load Test % Voltage Drop by Simulating a 20 Amp Load Test , ST-1D indicates proper wiring, voltage drop and line voltage in an easy pass/fail format. A simple ... IDEAL Industries
Original
datasheet

8 pages,
59.82 Kb

Neutral grounding resistor GFCI BREAKER cycolac 61175 UL1436 61-152 Square D GFCI TEXT
datasheet frame
Abstract: LT6110 LT6110 Cable/Wire Drop Compensator Features Description n n n The LT®6110 is a , control of small variations in wire voltage drop. L, LT, LTC, LTM, Linear Technology, the Linear logo , distribution. When a load draws current through a long or thin wire, wire resistance causes an IR drop that , the output voltage of an adjustable regulator to compensate for the drop in the wire. The accuracy , the load due to a wire resistance drop of 0.5V. Even if the wire resistance doubled, causing an error ... Linear Technology
Original
datasheet

38 pages,
511.04 Kb

LT6110 TEXT
datasheet frame
Abstract: AMP Mini-Drop Wire Splice The AMP Mini-Drop wire splice provides a compact, waterproof drop wire splice. Advantages: · · Easy to Install - IDC contacts: no special tools or wire stripping , 216 type tool. Splice Installation Step 1 Separate drop wire leads approximately 1 inches (25.4mm) or as measured by RIB indicators on connector housing. If drop wire is double insulated, strip , approximately 45°, as shown, to aid in inserting wire into splice. Step 2 Insert drop wire leads into splice ... Tyco Electronics
Original
datasheet

2 pages,
196.65 Kb

PC102 in line splice wire TEXT
datasheet frame
Abstract: Figure 3. Wire Size Test Current Terminal Millivolt Drop (maximum) Tensile Strength (pounds , the wire receiving end of the terminal. Also, 4 equal wire length (EWL) voltage drop measurements , wire conforming to Mil-W-22759. 1.5. Test Specimens Test specimens were representative of normal , Group ID Part Number & Revision Level Wire Size (AWG) Stud Size (Inch) 1,2,3,4 323167 , examination of product 1 1 1 | Voltage drop 3 3 3 Vibration, sinusoidal 2 ... Tyco Electronics
Original
datasheet

4 pages,
33.34 Kb

terminal block test qualification stratotherm CTL3066002 323169 stratotherm 323180 CTL3010-002 TEXT
datasheet frame
Abstract: Illustration of Millivolt Drop Measurement Procedure Military Specification MIL-T-7928G MIL-T-7928G Wire Size AWG 22 , Results MVD SOLISTRAND Millivolt Drop Results Per MIL-T-7928G MIL-T-7928G Using Military Approved Wire 10 , Current Cycling B A B C Voltage Drop Vibration Voltage Drop Tensile Salt Spray/Corrosion B C Voltage Drop Tensile A Heat Age B Salt Spray/Corrosion C D 2 Test Type A 1 Test Sequence Voltage Drop Tensile 3 4 Test Description Samples subjected ... AMP
Original
datasheet

5 pages,
132.94 Kb

TEXT
datasheet frame
Abstract: . shall occur 2. ELECTRICAL 2.1A Voltage drop ( IDC connectors ) REQUIREMENTS - 6,0 mVA wire size , between contact body and wire barrel ) -Voltage drop within limits indicated for new contacts -No , 1.11A SINE VIBRATION TEST ELECTRICAL REQUIREMENTS 2.1A VOLTAGE DROP 2.2A DIELECTRIC STRENGTH 2.3A , MECHANICAL REQUIREMENTS 1.1B WIRE RETENTION A7 ADDED NEW PRODUCT ON TABLE PAGE 2 M. POLIZZI O , A max. with 0.75 mm2 wire for contacts 3.50 mm pitch 6 A max. with 0.50 mm2 wire for contacts 2.54 ... AMP
Original
datasheet

12 pages,
322.61 Kb

1745005 284136-1 100N 1745005-1 fiat 91107 AMP Multilock fiat 91107/03 mqs contact fiat 91107 13 fiat 91107 18 TEXT
datasheet frame
Abstract: LT6110 LT6110 Cable/Wire Drop Compensator Features Improve Voltage Regulation to a Remote Load by 10 , through a long or thin wire, wire resistance causes an IR drop that reduces the voltage delivered to the , compensate for the drop in the wire. The accuracy and wide output current range of the LT6110 LT6110 allow it to , regulator circuit has 10% regulation at the load due to a wire resistance drop of 0.5V. Even if the wire , covered in later sections. Step 1: Determine the drop in voltage at the load due to the wire resistance ... Linear Technology
Original
datasheet

38 pages,
509.86 Kb

LT6110 TEXT
datasheet frame
Abstract: on transition zone between contact body and wire barrel) -Voltage drop within limits specified for , increase 70 °C on transition between contact body and wire barrel -Voltage drop within 50% increase of , : Tyco Part Number Description "Trade Mark" Wire range (for contact only) 282956-1 to -8 2 , 828906-2 or, in alternative, 282081-1 SINGLE WIRE SEAL 1. 5÷2.5mm2 1.2÷2.1mm DIA SINGLE WIRE SEAL 2.2÷2.7mm DIA SINGLE WIRE SEAL >2.7÷3.0mm DIA CAVITY PLUGS / These connectors ... AMP
Original
datasheet

10 pages,
197.08 Kb

Z8510 828904-1 828905-1 967541-1 967543-1 991320 AMP 828905-1 fiat tensile strength crimping pull test FTEC174 106462 9.91320 Z8260 282081-1 fiat 9.91320 SPECIFICATION 7.Z8260 106462-1 7.Z8260 TEXT
datasheet frame