500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

"di up"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: risulterà a livello del pannello. Le linguette a scatto consentono di mantenere saldamente in posizione il , in a snap-in DIN-sized enclosure. · 6 Digit Up/Down Counting · Password Protection · 5 Open , . Take High to count up. Take Low to count down. High Alarm output. Open collector output, capable of sinking up to 50mA. Goes Low when the reading is equal to or larger than the preset Hi Alarm value.* Low Alarm output. Open collector output, capable of sinking up to 50mA. Goes Low when the reading is equal Lascar Electronics
Original
photocoupleur C100 circuito triac led infrarouge resistenze Triac v P9-15 P16-22 P23-29
Abstract: funzione Funzione di controllo del livello (B e E) UP = Riempimento, DOWN = Svuotamento Funzione , CM-ENS, CM-ENS UP/DOWN CM-ENN, CM-ENN UP/DOWN Betriebs- und Montageanleitung , montaggio Relè di controllo del livello di liquidi, serie CM (RU) Nota: Le presenti istruzioni per l'uso ed il montaggio non contengono tutte le informazioni dettagliate su tutta la gamma di prodotti e , descrivere il prodotto e non sono da interpretare come caratteristiche garantite con valore di legge. Per ABB Automation
Original
F0004 potenciometro de 5k potenciometro 5k RELE CONMUTADOR led amarillo relais schema cmenn
Abstract: mm 1 - Configurazione: scelta della modalità di funzionamento. Up / Down e della gamma di , 3.54 R (Up) Up Rangos de medida Gamme di misurazione Measuring subrange Sous gamme de , On delay A1 A2 1 Off delay Min Max C Up HS St. LS Sensitivity 1 U U , di 1 livello con temporizzazione all'avviamento. 12/22 Tt (2) 12/22 ON Level 11/21 , Auslöseverzögerung. / Control de 1 nivel con temporización en el desenclavamiento. / Controllo di 1 livello con -
Original
potenciometro ajustable fusible ultra rapide potenciometro 10 K rele time fusibile potenciometro 100 K
Abstract: be put to the same UP rail as the module itself. 07 DI 90-S E0 E1 E2 Electrical , 4 Binary input module 07 DI 90-S, safety-related, 24 V DC, 8 inputs, electrically isolated from the CS31 system bus TEST 07 DI 90-S Advant Controller 31-S Input Unit Figure 4-1: Safety-related binary input module 07 DI 90-S Contents Intended purpose , DI 90-S is a binary input module with 8 input channels for 24 V DC safety-related sensors. 4-1 -
Original
AC31-S led disply module KT 907 AC31 GJR5 safety manual
Abstract: . Up / Down - Potenziometro di regolazione della temporizzazione. Tt - Commutatore di selezione del , . / Controllo di 1 livello con temporizzazione all'avviamento. (2) Tor Level 11 14 11 (2 , consigna de temporización (ajustable en fachada) / Fine dell'istruzione di temporizzazione (regolabile sul pannello anteriore). 4/4 - Configuration: selection of the operating mode. Up / Down - Time delay , 3 4 5 6 7 - Configuración: selección del modo de funcionamiento. Up / Down - Potenciómetro -
Original
control de temperatura Relais 12v IEC60664-1/60255-5
Abstract: Bedienungsanleitung I Relè di controllo tensione monofase Istruzioni d'impiego P Relé de controlo de , if the fault is not removed. Choix des seuils: seuil haut si Up ou Up Lo seuil bas si Lo ou Up , (Klemmen 5+ und 9­). Select operating mode: overvoltage monitoring (Up) undervoltage (Lo) or band (Up Lo) Select t1 delay (second) Es bietet folgende Konfigurationsmoglichkeiten: · Auswahl der , . 1) Select thresholds: high threshold if Up or Up Lo Iow threshold if Lo or Up Lo Define -
Original
afficheur lcd
Abstract: dispositivi soltanto (trasmettitore e ricevitore). ON OFF UP DOWN Le porte di comunicazione RS232 e , avanti (UP). - Premendo INVIO, si alterna la direzione di temporizzazione tra UP (avanti) e DOWN , avanti "Up"). Non connesso. Utilizzare il Menu per selezionare la direzione di temporizzazione. Non , risulterà a livello del pannello. Le linguette a scatto consentono di mantenere saldamente in posizione il , value (timing Down) or to zero (timing Up). Not connected. Use Menu to select direction of timing. Not Lascar Electronics
Original
C120
Abstract: Up and Down Arrows to select the desired Baud rate from 1200, 2400, 9600 and 19200 Baud. Porte di , risulterà a livello del pannello. Le linguette a scatto consentono di mantenere saldamente in posizione il , Stellen Sie die Verbindungen LK3 und LK4 her. Misurazione della tensione di un ingresso con polo in comune e fondo scala di 2 V c.c. rispetto alla messa a terra di alimentazione (IN LO è collegata , her und trennen LK4 durch. Misurazione di una corrente continua (ad esempio: 4-20 mA, 0-2 A, 0-20 A Lascar Electronics
Original
LED DISPLAY starburst led infrarossi P10-17 P18-25 P26-33
Abstract: Ingresso input pull up. Permette di entrare in modalità apprendimento (vedi procedura di apprendimento , nulla a questo pin Input pull up. Selezione tipo di costa: Sel tipo costa 1 = Sel tipo costa 2 = GND , (NON IMPLEMENTATO). 20 GND Ingresso input pull up. Permette di entrare in modalità , '™uscita viene forzata a massa. Connessione al piano di massa Input pull up. Non collegare per , compresa tra 1.8 e 3.6 Volt. Modulo single in-line con dimensioni di 51 x 25 mm, con antenna integrata e AUREL
Original
Abstract: commons, enabling drive of up to 96 cells. ·Applications terminals, POS terminals, ECR Multi-media , , and others ·Features segment outputs and 3 common outputs 1) Up to 32 3) Either 1 / 2 or 1 / 3 , / BU9716BKV ·Block diagram VDD1 LCD Power VDD2 RES CS CTRL Logic DATA Latch DI CK , S16 OSC S16 OSC S15 CS S15 CS S14 CK S14 CK S13 DI S12 , DI S18 BU9716BKV S1 BU9716BK VDD2 S11 COM2 S12 Standard ICs BU9716BK ROHM
Original
QFP44 VQFP48
Abstract: 8 Ripple & Noise (NOTE 1) BW = 5Hz to 20MHz 90 Output Adjust Range Trim Up 8 , + Vout2 - Vin Figure 1 â'" Trim Up Circuit ON/OFF To lower the converter output voltage , 0 to 85oC and for airflows up to 600LFM. In each case the maximum allowable power at a given , provided showing output voltage response and timing to input voltage power up/down, Remote ON/OFF state , Efficiency vs. Input Voltage @ TA = +250C @ TA = +250C Trim Up Graph Trim Down Graph Turn On C&D Technologies
Original
WPA60R48DC EN60950 ISO9001 CISPR22/EN55022/FCC15J WPA60R48D1812C WPA60R48D1510C
Abstract: commons, enabling drive of up to 96 cells. ·Applications terminals, POS terminals, ECR Multi-media , , and others ·Features segment outputs and 3 common outputs 1) Up to 32 3) Either 1 / 2 or 1 / 3 , / BU9716BKV ·Block diagram VDD1 LCD Power VDD2 RES CS CTRL Logic DATA Latch DI CK , S16 OSC S16 OSC S15 CS S15 CS S14 CK S14 CK S13 DI S12 , DI S18 BU9716BKV S1 BU9716BK VDD2 S11 COM2 S12 Standard ICs BU9716BK ROHM
Original
Abstract: risulterà a livello del pannello. Le linguette a scatto consentono di mantenere saldamente in posizione il , ) Programmierbarer Frequenzmesser P16-22, 30-32 Contatore di frequenza programmabile P23-29, 30-32 2.54 (0.10 , filtering is used. Not connected. High Alarm output. Open collector output, capable of sinking up to 50mA , enabled) Low Alarm output. Open collector output, capable of sinking up to 50mA. Goes Low when the , button. External switch input. Take Low to mimic the front panel UP button. External switch input. Take Lascar Electronics
Original
Abstract: DOWN RESISTOR OF CS PIN â'¢ PULL UP/DOWN RESISTER OF DO PIN 7 I/O PORT (TO CONNETCT DI AND DO) â , power up with write-disabled state Software instructions for write-enable/disable Write inhibit at low , -8:81 -0- 0.08®) 0.087S Fig. 1-8 Outline Dimensions SSOP-B8(BR93L66RFV-W) cs sk DI do , BR93L66-W : DIP8 1 CS SK DI DO OTERMINAL FUNCTION Terminal IN/OUT Function Vcc â'" Power Supply GND â'" Ground (OV) CS INPUT Chip Select Control SK INPUT Serial Data Clock Input DI INPUT Start Bit, Op. code -
OCR Scan
BR93L66F-W BR93L66FV-W BR93L66RF-W BR93L66RFJ-W BR93L66RFVM-W BR93L66/F/RF/FJ/RFJ/FV/RFV/RFVM-W
Abstract: output segments and 3 common outputs, enabling drive of up to 96 segments. A compact 48-pin QFP package , section is 7.0mmã) 4) Up to 32 segment output pins and 3 common output pins are provided, enabling a total display of up to 96 segments. 5) 1/3 duty display. 6) Either 1/2 or 1/3 bias can be selected , , DI, RES -0.3 to VDD+0.3 VOUT OSC -0.3 to VDD+0.3 V ISO S1 S32 300 uA , Driver ICs !Block diagram VDD1 VDD2 LCD Power RES CS DI CTRL Logic DATA Latch CK ROHM
Original
BU9718KV
Abstract: parte posteriore. In alternativa, il contatore e la cornice possono essere assemblati prima di essere , (0.35) 24 (0.94) 48 (1.89) Collecteur de Données TM Compatible WINDOWS Registratore di , OPERATION (Make sure logger is set up correctly within EL-WIN software.) or 2. PUSH TO START if , - EL-WIN-Lite. Easy to install and use, the control software will allow the user to set up the , module has a memory capacity of up to 8064 readings, and a battery life of up to 3 years.* EL-Lite can Lascar Electronics
Original
Maxell ER3S-TC SL-750 fiche jack 3.5mm MAXELL ER3STC Sonnenschein Lithium 3,6
Abstract: La serie di telecamere colore LTC0485 ad alte prestazioni, dotate di sensore XF-Dynamic CCD , XF-Dynamic, estende la gamma dinamica. La condizioni di illuminazione e di scena non ottimali. telecamera , ottimale i dettagli della scena anche quando la Le telecamere DinionXF, con l'esclusiva tecnologia di elaborazione video luce risulta eccessiva oppure insufficiente digitale a 15 bit e dotate di XF-Dynamic , funzione Auto black consente di migliorare il contrasto della scena garantiscono una sensibilità superiore Gamma Commerciale
Original
PIU ALARM Manual bosch vp-usb vp-usb TC220PSX-24 TC220PS bosch relay equivalent 119/B
Abstract: Power Integrations solution ­ · Eliminates up to 50 discrete components, reducing board, layout and , , LinkSwitch, LinkSwitch-XT up to 300% Peak Power PeakSwitch (continuous) 85-265 VAC 230 VAC 0W , Switching Frequency (kHz) II. VERY LOW POWER AC-DC POWER CONVERSION (UP TO 6 W) PWM PWM PWM Y Y , Current Limit III. LOW POWER AC-DC POWER CONVERSION (UP TO 36.5 W) Product Selector Guide Y Y , Product3 Continuous Output Power Peak Power Delivery IV. SUPER PEAK AC-DC POWER CONVERSION (UP TO Power Integrations
Original
tny280 flyback flyback samsung lnk306 TNY276 tny 290 TV flyback transformer EP-14 EP-16
Abstract: APPLICATION CIRCUIT · PULL DOWN RESISTOR OF CS PIN · PULL UP/DOWN RESISTER OF DO PIN I/O PORT (TO CONNETCT DI , Auto-increment of registers address for Read mode Prevent inadvertent writing Defaults to power up with , OPIN CONFIGURATIONS Vcc NC NC GND NC GND DO DI Vcc I il NC il NC li GND I BR93L56-W : DIP8 , BR93L56RFV-W : SSOP-B8 BR93L56RFVM-W : MSOP8 0 1 i CS SK DI DO 0 CS SK DI DO NC Vcc CS SK Fig.-3 Pin Configurations OTERMINAL FUNCTION Terminal Vcc GND CS SK DI DO NC IN/OUT - - INPUT INPUT INPUT OUTPUT Power -
OCR Scan
BR93L56/F/RF/FJ/RFJ/FV/RFV/RFVM-W 310GK5
Abstract: trasformatore d'intensità Scelta della modalità di funzionamento: controllo alta-intensità (Up , User instructions D Stromüberwachungsrelais einphasig Bedienungsanleitung I Relè di , fonctionnement, surveillance Sur-intensité (Up) Sous-intensité (Lo) bande (Up Lo) Display shows measured , Overcurrent monitoring (Up), Undercurrent (Lo) or Band (Up Lo) Select thresholds High threshold if Up or Up Lo Low threshold if Lo or Up Lo Define hysteresis Hys (Amp) Select t1 delay (second) Select -
Original
KFE103 transformador
Showing first 20 results.