500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
LB11685VH-TLM-H ON Semiconductor Three-Phase Brushless DC Sensor-less Motor Driver, HSOP28 (275mil), 2000-REEL

"dc Current Sensor"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: Point Leakage Current Nam co Focused Field FlatPak Sensor. A clean wave m eans predictable perform ance. Leakage Current Power-up current draw of com petitive sensor will turn on PLC inputs , includes latching Short Circuit Protection (SCP). If the sensor detects excessive current, it reverts to , circuit, simplifying the troubleshooting task. The sensor draws minimal current (2mA) and can remain in , extended range sensor m ade in the USA. Available in either 20-150 VAC/DC or 10-30 VDC styles. 2013 Namco Controls
Original
EE500 1-800-NAMTECH
Abstract: Sensor. Note: UL certification has been obtained only for the DC three-wire models. Valve sensor , . Concerned about installation work? 6 V max. (AC load current: 400 mA, DC load current: 300 mA, Cable , output 200mA max. Insulation resistance 35.5 Sensor E2MP-ST1 AC/DC 2-wire Ambient , it for such purposes. Never use an AC power supply for a Valve Sensor specified for a DC power , , greatly reducing installation work. Proximity sensor main circuit DC 3-wire (NPN Output) OUT1 OMRON
Original
namur standard 2wire B1M1 75-344-7022/F D-71154 7032-811-0/F 847-843-7900/F 6835-3011/F 21-5037-2222/F
Abstract: Proximity Sensor. Load DC (voltage fluctuation, current capacity value) AC (voltage fluctuation , a Sensor that requires a DC power supply may cause explosion or burning. Load short-circuiting Typical examples DC 3-Wire NPN Output Sensors DC 2-Wire Sensors Load Brown Sensor Load Brown Sensor Black Blue Blue · DC 2-Wire Sensors · Even with the load short-circuit , + Sensor Blue Incorrect Wiring (Load short circuit) · DC 2-Wire Sensors · Even with OMRON
Original
E2S-W13B Omron RELAY RD2P npn transistor w16 inductive proximity sensor npn price of ir proximity sensor water level sensor circuit diagram high frequency welder circuit diagram E2S-W11 E2S-Q11 E2S-W21 E2S-Q21 E2S-W12 E2S-Q12
Abstract: electrical performance of the supply Proximity Sensor. Load DC (voltage fluctuation, current capacity , , or using an AC power supply (100 VAC or higher) for a Sensor that requires a DC power supply may , DC 2-Wire Sensors Load Brown Sensor Load Brown Sensor Black Blue Blue · DC 2 , explosion or burning. Blue DC 3-Wire NPN Output Sensors Load Brown Sensor - Black + If , type DC DC + S3D2 Controller AC Control output Maximum current (voltage) Leakage current OMRON
Original
omron H3CA circuit diagram water level sensor weight sensor circuit inductive proximity sensor omron proximity sensor TL-W20ME1 TL-W20ME2 TL-W5MD15
Abstract: DC 3-Wire NPN Output Sensors DC 2-Wire Sensors Load Brown Sensor Load Brown Sensor , . Load DC (voltage fluctuation, current capacity value) AC (voltage fluctuation, frequency, etc , 20 mT* max. Do not use the Sensor at a level higher than 20 mT. · Sudden changes in the DC magnetic field may cause malfunction. Do not use the Sensor for applications that involve turning a DC , . Influence of Leakage Current Even when the Proximity Sensor is OFF, a small amount of current runs through OMRON
Original
E2J-W10MA E2J-W20MA human detection sensors circuit human detection sensors capacitive sensor rd2p omron shock sensor amplifier rain sensor XS3Z-13 XS3Z-15 XS3W-M421-401-R XS3W-M421-402-R
Abstract: Proximity Sensor. Load DC (voltage fluctuation, current capacity value) AC (voltage fluctuation , a Sensor that requires a DC power supply may cause explosion or burning. Load short-circuiting Typical examples DC 3-Wire NPN Output Sensors DC 2-Wire Sensors Load Brown Sensor Load Brown Sensor Black Blue Blue · DC 2-Wire Sensors · Even with the load short-circuit , + Sensor Blue Incorrect Wiring (Load short circuit) · DC 2-Wire Sensors · Even with OMRON
Original
E2K-L26MC1 omron liquid level sensor capacitive level sensor omron liquid level sensor problem liquid level sensor capacitive small capacitive oil level sensor E2K-L13MC1
Abstract: Cable Amplifier Proximity Sensor E2EC High-sensitivity DC 2-Wire Sensors and Subminiature , Sensor main circuit Black * Output Blue 0V Maximum load current: 100 mA Note: The , DC 3-Wire NPN Output Sensors DC 2-Wire Sensors Load Brown Sensor Load Brown Sensor , . Load DC (voltage fluctuation, current capacity value) AC (voltage fluctuation, frequency, etc , 20 mT* max. Do not use the Sensor at a level higher than 20 mT. · Sudden changes in the DC magnetic OMRON
Original
E39-VA short distance distance sensor ir SUS304 SUS304 ni 0.15 powder level sensor circuit diagram OMRON PROXIMITY SWITCH E2EC-CR8D15 E2EC-CR5D15 Y92E-F5R4
Abstract: DC 100 AC 30 DC 30 AC 30 DC 30 Breakdown Voltage (VDC min.) 200 200 200 Switching Current (Amps max , .@ 5VDC Input Current, Output(s) Shorted to Ground 25 mA, max. per output Max Overvoltage Sensor Output , typical 5 V DC to 24 V DC range of Hall sensors. They can effectively switch 110 V ACac at low current , High-Performance Sensors for Demanding Environments Cherry offers seven standard sensor product series: broad , sensor, Cherry provides the design expertise and development tools needed to bring your product to market Cherry
Original
vane air flow sensor GS1005-1009 Mini Project Temperature Sensor delphi metri-pack 150.2 delphi metri-pack 150.2 12162833 delphi ip68 connector
Abstract: Proximity Sensor. Load DC (voltage fluctuation, current capacity value) AC (voltage fluctuation , Sensing object DC 2-wire Proximity Sensor main circuit Not present E2FQ-X2D1 E2FQ-X5D1 , DC 3-Wire NPN Output Sensors DC 2-Wire Sensors Load Brown Sensor Load Brown Sensor , 20 mT* max. Do not use the Sensor at a level higher than 20 mT. · Sudden changes in the DC magnetic field may cause malfunction. Do not use the Sensor for applications that involve turning a DC OMRON
Original
E2FQ-X10D1 E2FQ-X10Y1 OMRON TL X5Y1 G water level inductive sensor near ir flame sensor welder circuit diagram rectification sensor flame proximity sensor E2FQ-X10E1
Abstract: Sensor IP67 Nylon Nylon PVC 2M, 7mm, 7X22AWG 1.0.10.0mm Non-Flush 24V DC ± 5% £ 100mA 12V , Transmitter ç·····è Output Sensor Number of Signals Housing Size Mounting Rated Sn 1 Signal M18 X 1 Non flush 0.4.0mm M18x1 Transmitter ç·····è Output Sensor 1 Signal M30 X 1 Non flush , -1804-N-01 For 2 wire detector Sensors BES-RPT-1804-D-01 Output Sensor PNP Output NPN Output Sensing Distance Rated operational voltage Drive Current Drive Voltage Center off-set Short circuit protection Balluff
Original
3X22AWG BES-RPE-1804-N-02 BES-RPEM-4502P-ST BKS-S48M-IN-LINE RGPT-3005 RGPT-9012-V2430-PU-05 RGPE-9012-V2430P-PU-05 bks-s connectors BES-RPTA-1803-01 BES-RPT-1804-P-01 BES-RPT-1804-N-01 BES-RPE-1804-P-02 IEC529
Abstract: Proximity Sensor. Load DC (voltage fluctuation, current capacity value) AC (voltage fluctuation , voltage range, or using an AC power supply (100 VAC or higher) for a Sensor that requires a DC power , Output Sensors DC 2-Wire Sensors Load Brown Sensor Load Brown Sensor Black Blue , 20 mT* max. Do not use the Sensor at a level higher than 20 mT. · Sudden changes in the DC magnetic field may cause malfunction. Do not use the Sensor for applications that involve turning a DC OMRON
Original
E2F-X10E1 E2F-X10E2 vehicle rain sensor OMRON RELAY Cross Reference MAGNETIC PROXIMITY SENSOR IP68g E2F-X10Y1 E2F-X10Y2 E2F-X5E15 E2F-X5Y1-53
Abstract: Residual Load Voltage 5 10 20 30 50 100 OFF 200 Load current (mA) I/O Circuit Diagrams DC 3 , Output Sensors DC 2-Wire Sensors Load Brown Sensor Blue Black Load Brown Sensor Blue Power Supply , , influence of voltage, etc. DC (voltage fluctuation, current capacity value) AC (voltage fluctuation , Steady-state current, inrush current Open/close frequency Selecting the power supply type DC DC + S3D2 , field is 20 mT* max. Do not use the Sensor at a level higher than 20 mT. · Sudden changes in the DC OMRON
Original
E2K-X15ME1 E2K-X15MY1 E2K-X15ME2 E2K-X15MY2
Abstract: voltage range, or using an AC power supply (100 VAC or higher) for a Sensor that requires a DC power , Output Sensors DC 2-Wire Sensors Load Brown Sensor Load Brown Sensor Black Blue , and the electrical performance of the supply Proximity Sensor. Load DC (voltage fluctuation , supply type DC DC + S3D2 Controller AC Control output Maximum current (voltage) Leakage current , DC magnetic field may cause malfunction. Do not use the Sensor for applications that involve turning OMRON
Original
TL-T2E15 TL-T2E1 TL-T5ME1 TL-T2F1 resistive humidity temperature sensor E39-V
Abstract: SENSOR KIT Supply Voltage 10-30V DC 20-230V AC/DC ≤2.5V @ 200mA ≤2.0V@≤100mA Voltage , this occurs, both LED's will flash and the sensor will limit current flow to about 2.0mA. 3000 Wiring Diagram 2WAC/DC L1 (master sensor) Master Sensor Output Remote Sensor Output Gnd See page 79 for LP2 dim ensions. L1 (remote sensor) 3WDC Remote Sensor Output + DC Master Sensor , Proximity Sensors Weld Field Immune Tandem Low Profile Power Clamp Sensor Kit â Namco Controls
Original
EE270-2
Abstract: will flash and the sensor will limit current flow to about 2.0mA. 3 Wire DC N. O. N.O. LOAD 1 , Hardened Flatpak ® Proximity Sensor is the first long range sensor designed to operate reliably in the , failure in the harsh mill environment, the MillPak proximity sensor has been designed to effectively combat the effects of both problems, increasing the life expentancy of your sensor. The MillPak proximity sensor has been sealed to provide a high degree of liquid resistance, allowing the sensor to be Namco Controls
Original
Abstract: ., E2E-X3D1-N 5M). E2E/E2E2 Cylindrical Proximity Sensor 1 DC 2-wire/Connector Models Connector M12 , E2E-X20MD1-M1 E2E-X20MD2-M1 2 E2E/E2E2 Cylindrical Proximity Sensor DC 3-wire/Pre-wired Models Size , (e.g., E2E-X2Y1 5M). E2E/E2E2 Cylindrical Proximity Sensor 3 DC 3-wire/Connector Models , model number (e.g., E2E-X7T1 5M). 4 E2E/E2E2 Cylindrical Proximity Sensor E2E2 DC 2 , residual voltage. 8 E2E/E2E2 Cylindrical Proximity Sensor E2E-X@E@/F@ DC 3-wire Models Size Type OMRON
Original
E2E-X20MD1S E2E-X1B1-M5 E2E-XD15-M1G E2E2-X10MB1 E2E2X5C2M E2E-X10D1S E2E-X14MD1S E2E-X10D1-N E2E-X14MD1 E2E-X20MD1
Abstract: Proximity Sensor. supply Load DC (voltage fluctuation, current capacity value) AC (voltage , DC 3-Wire NPN Output Sensors DC 2-Wire Sensors Load Brown Sensor Load Brown Sensor , Sensor Blue Incorrect Wiring (Load short circuit) · DC 2-Wire Sensors · Even with the load , , inrush current Open/close frequency Selecting the power supply type DC DC + S3D2 Controller AC , DC magnetic field may cause malfunction. Do not use the Sensor for applications that involve turning OMRON
Original
IT16 OMRON RD2P omron TL-T2Y1
Abstract: performance of the supply Proximity Sensor. Load DC (voltage fluctuation, current capacity value) AC , Proximity Sensor main circuit Output circuit Black * Output Blue 0V * Load current , supply (100 VAC or higher) for a Sensor that requires a DC power supply may cause explosion or burning , Brown Sensor Load Brown Sensor Black Blue Blue · DC 2-Wire Sensors · Even with the , burning. Blue DC 3-Wire NPN Output Sensors Load Brown Sensor - Black + If the power OMRON
Original
E2K-F10MC1 E2K-F10MC2 inductance proximity sensor ir proximity sensor circuit diagram IR rain light sensor ultrasonic water level sensor proximity-Sensor E2K-F10MC1-A E2K-F10MC2-A E2K-F10MC
Abstract: Product Manual 1122 - 30 Amp Current Sensor AC/DC Phidgets 1122 - Product Manual For Board , Current Sensor AC/DC to the Analog Input 6 on the PhidgetInterfaceKit 8/8/8 using the sensor cable. 2. To , 30Amp Current Sensor [DC] or [AC] from the drop down menu. 2. The current measured across the sensor is , 30 Amp Sensor measures alternating current (AC) up to 30 Amps and direct current (DC) between ­30 and , measure both the AC and DC components of complex current waveforms separately. Connections Designed to Phidgets
Original
Phidgets 2000/XP/V 110VAC 240VAC GMT-07
Abstract: DC 3-Wire NPN Output Sensors DC 2-Wire Sensors Load Brown Sensor Load Brown Sensor , . Load DC (voltage fluctuation, current capacity value) AC (voltage fluctuation, frequency, etc , 20 mT* max. Do not use the Sensor at a level higher than 20 mT. · Sudden changes in the DC magnetic field may cause malfunction. Do not use the Sensor for applications that involve turning a DC , . Influence of Leakage Current Even when the Proximity Sensor is OFF, a small amount of current runs through OMRON
Original
E2EV-X10C1 E2EV-X10C2 E2EV-X2C1 inductive human proximity sensor 2 wire resistive Humidity Sensor
Showing first 20 results.