500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
10-4 Signal Transformer Inc Power Transformer
12.8-4 Signal Transformer Inc Power Transformer
16-2 Signal Transformer Inc Power Transformer
24-1 Signal Transformer Inc Power Transformer
36-2 Signal Transformer Inc Power Transformer
56-25 Signal Transformer Inc Power Transformer

"constant voltage transformer"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: capacitor plate area r = relative dielectric constant O = dielectric constant of air = 8.85 x 10-12 farads / meter = dielectric constant V = voltage t = thickness or plate separation Q = charge In , of the field vector, Ej, multiplied by its corresponding dielectric constant, ij: D1 = D2 = D3 = , , therefore, essential to maintain a constant axis numbering scheme. # Axis Z (3) 1 X poled 2 Y 3 Z , C L Z Mechanical Unit Voltage (Volts) Current (Amps) Charge (Coulombs) Capacitance -
Original
CI LM 4800 piezoelectric cantilever ELECTRICAL CALCULATION FOR TRANSFORMER PZT Transducer G332 PZT -1 thinner
Abstract: concert to create high voltage step-up ratios. (Figure 3) The input portion of the transformer is driven , : Force or Vibration Results in Output Voltage TRANSFORMER A VDRIVE A CONDUCTOR INPUT , PZT Construction Figure 3. Transformer: Applied Voltage Results in Vibration Which Causes Output , of air = 8.85 × 10 ­12 farads/meter = Dielectric constant V = Voltage t = Thickness or plate , Voltage Down to Size Jim Williams, Linear Technology Corporation Jim Phillips, Gary Vaughn, CTS Wireless Linear Technology
Original
laptop LCD inverter SCHEMATIC PZT Transducer ultrasonic laptop CCFL inverter SCHEMATIC inverter PURE SINE WAVE schematic marine sonar laptop inverter ccfl 200VAC 800VAC LT1375 AN81-23 AN81-24
Abstract: daykin ELECTRIC CORPORATION CONSTANT VOLTAGE CVFS SERIES - TRANSFORMER DISCONNECT TRANSFORMER DISCONNECT 13 The Daykin CVFS Series combines a constant voltage transformer with a , )261-3352 TD3-0496 daykin ELECTRIC CORPORATION CONSTANT VOLTAGE CVFS SERIES - TRANSFORMER , ) mounting configurations Separate Auxiliary VA Constant Voltage VA Model Approx. Wt. (LBS , ):S61-3352 ! 1)4 049B daykin ELECTRIC CORPORATION CONSTANT VOLTAGE - CVFS SERIES Schematic 2 -
OCR Scan
CV-FS Series CV-FS CVFSM3101
Abstract: electronic transformer. Electronic Transformer Executes a constant power control algorithm , boost output voltage to reach the regulation target set by constant KMode2(target). If boost output , transformer by measuring the conduction angle of the rectified voltage every half-line cycle. The LED output , an electronic transformer. The CS1680 regulates boost output voltage VBST while maintaining the , current inversely proportional to the boost output voltage. The algorithm attempts to maintain a constant Cirrus Logic
Original
CS1680-00 CS1680-02 12VAC/VDC DS1055F1
Abstract: on page 8 and in our Variable Transformer Voltage Control Catalog (VT-5). These models include cased , systems. Complete information is contained in our Variable Transformer Voltage Control Catalog (VT-5). , . MAX. AMPS. KVA 15.69 [398.4] * Voltage Doubler operation, refer to Variable Transformer , transformer with a 0 to 100 percent adjustable output voltage range. The â'Quick-Stepâ' is shipped fully , Transformer is available in ratings of 3 to 25 amperes with output voltage ranges of either 0 to 120 volts or Staco Energy Products
Original
30M6020-9Y 30M5011-3Y 221B-3 501C-3 1010B-3 6011-3Y
Abstract: used to provide isolation and transform the line voltage to a lower level. The transformer's output , rating is determined by the optocoupler's pin spacing and transformer's insulation. Constant Current , slope compensation. Constant Voltage State (t2-t3) When the pack reaches its final voltage (t2), constant voltage control is initiated, causing the battery current to decrease. Because Lithium-Ion batteries have safety concerns associated with the over-charging of cells, a timed constant voltage period Unitrode
Original
UNITRODE DIODE CROSS laptop battery diagram schematic laptop charger schematic unitrode catalog unitrode Applications Note lm358 sum U-168 UCC3809 UCC3956 120VAC
Abstract: constant current and constant voltage charging controls. This application note examines such a , SMPS based on constant voltage and constant current control. 1. Charger/AC Adapter for Lithium Ion , are constant voltage, 2 constant current control, design of the primary power section, protection, and design considerations. 1.1 Constant current, constant voltage control circuitry A simple and accurate constant current, constant voltage control using the Fairchild LM393 comparator is shown Fairchild Semiconductor
Original
AN4101 KA5M0265R overvoltage protection using lm393 KA5L0165Rv 7d431 smps 800W pwm for 800w active snubber IC201A KA1H0165RN KA1H0165R KA5L0165RV KA5M0165RV
Abstract: constant current and constant voltage charging controls. This application note examines such a , . Charger SMPS based on constant voltage and constant current control. 1. Charger/AC Adapter for Lithium Ion Batteries constant voltage, constant current control, design of the primary power section , circuit (SMPS) having constant voltage, constant current operating characteristics. Among the topics discussed in this application note are 1.1 Constant current, constant voltage control circuitry 2 Fairchild Semiconductor
Original
ee1614 cx102 lm393 charger DF06-644 fairchild lm393 222 1KV
Abstract: constant current, constant voltage (CC/CV) primary sensed output characteristic ­ No optocoupler or sense , to yield a constant voltage/constant current output characteristic without secondary-side sensing , provides a CV/CC (constant voltage/constant current) type output characteristic from a universal input , conducting, the voltage across the transformer primary is equal to the output voltage plus diode drop , Features · · · · · Very low cost, low component count charger/adapter - replaces linear transformer Power Integrations
Original
LNK501P wt-200 1N4005 TOPSWITCH battery charger SBCP-47HY102B MUR110 17F-3
Abstract: constant current and constant voltage charging controls. This application note examines such a , SMPS based on constant voltage and constant current control. 1. Charger/AC Adapter for Lithium Ion , are constant voltage, 2 constant current control, design of the primary power section, protection, and design considerations. 1.1 Constant current, constant voltage control circuitry A simple and accurate constant current, constant voltage control using the Fairchild LM393 comparator is shown Fairchild Semiconductor
Original
KA5H02659RN AN-4101 KA5H0165R 400w power supply c945 smps 40v 100w smps 3kw
Abstract: off, the adapter must maintain a continuous regulated voltage, and when on, it delivers a constant , constant frequency. An auxiliary winding delivers the primary low voltage needed for supplying the , across the primary of the transformer at Vs. This voltage Vs must be higher than n.Vout, and the coupled part of the transformer is submitted to an intermediate voltage between Vs and n.Vout. Figure 6 , resulting detection delay noted ts on figure 8 can be considered as constant, even if the output voltage STMicroelectronics
Original
AN946 VIPER100 Application Note VIPER31 Application Note flyback converter flyback transformer formula VIPER31 AN1073
Abstract: Transformer Voltage Control Catalog (VT-5). These models include cased and uncased, single and three phase , in our Variable Transformer Voltage Control Catalog. To serve your needs promptly, Staco Energy has , *Voltage Doubler operation, refer to Variable Transformer Voltage Control Catalog (VT-5). Data is subject , channel feedback and control Controls variable voltage transformer regulation to within +/-0.5 volts , . Please refer to our Variable Transformer Voltage Control Catalog (VT-5) for additional information Staco Energy Products
Original
LR18948
Abstract: PRofessional AV over IP DATA SHEET < VIEWâ"¢|Constant Voltage Transformer XT9170 - Transformer ClearOneâ'™s Constant Voltage Transformer allows VIEW Amplifiers to be used with 70V or 100V speaker systems. Applications Constant Voltage Transformer Advantages +Conferencing +Converts 8 , . This allows the transformer to be used standalone, or with ClearOne VIEW, allowing for a bridge , < > VIEW REAR PANEL > Speakers per XT9170 Zone / Transformer Tap Settings Note - The chart shows Clearone
Original
SL254 SL251 SL9250 AMP2200 802-000-043-DS
Abstract: %. STACO Variable Transformers deliver any desired voltage (within the transformer rating) with negligible , and provides the transformer with greater tolerance to transients and short-term overloads. VOLTAGE , maintaining a constant contact voltage drop). SIMPLE INSTALLATION AND CONNECTION Mounting and hook-up of , manufacturing cycle. A STACO Variable Transformer provides accurate, reliable and lasting voltage control for a , . ROTATION: Rotation of STACO Variable Transformer shaft gives increase in output voltage (as viewed from Staco Energy Products
Original
1010B 1210B staco switches staco wye delta start 1510 STACO FRC-20 221-B 501-B 1020B
Abstract: cover battery chargers with constant current and constant voltage output characteristics, without any , voltage to keep the average output current constant. To be connected to an external filtering capacitor , 100, 200, 300, 400 VDC, Ta = 25°C 1 Constant voltage operation (+/-7%) Iout (A) IDlim 0.8 Constant current operation (+/-2.5%) 0.6 t 0.4 ID Short circuit or Low voltage operation , topology cannot be easily kept constant, as it depends on the output voltage. Actually, if the peak STMicroelectronics
Original
sc12040 snubberless APPLICATION NOTE sc12150 SC12120 SC1210 SC12060 SO-10 0068039-C
Abstract: by device current limit. The superimposed dashed lines are contours of constant TOPSwitch-GX device , points. The shaded region indicates the output power where a flyback design at the given output voltage , output diode and capacitors. Higher output power can be obtained if the output voltage is higher. The , ) Start the design. Use the TOPSwich-GX Transformer Design Spreadsheet or PI Expert. Note: See , voltages the reader should be aware that altering the output voltage will give dramatic changes in Power Integrations
Original
AN-29 TOP243 equivalent TOP249 TOP244 topswitch 243Y TOP246 equivalent flyback top249 AN-21 AN-26 VAC-265
Abstract: cover battery chargers with constant current and constant voltage output characteristics, without any , auxiliary unregulated voltage from the main transformer, which can range from 7V up to 27V during normal , 100, 200, 300, 400 VDC, Ta = 25°C 1 Constant voltage operation (+/-7%) Iout (A) IDlim 0.8 Constant current operation (+/-2.5%) 0.6 t 0.4 ID Short circuit or Low voltage operation , VIPer31SP topology cannot be easily kept constant, as it depends on the output voltage. Actually, if the STMicroelectronics
Original
SC1203 11 pin flyback transformer schematics SC12160 SC1215 SC1213 sc1208
Abstract: output voltage range of a constant current power supply. CONSTANT CURRENT POWER SUPPLY: A power supply , Test. A test to determine if the breakdown voltage of a transformer or power supply exceeds the minimum , . FERRORESONANT POWER SUPPLY: An open-loop voltage stabilized power supply in which a portion of the transformer , portion of the transformer and is relatively independent of input voltage. FLYBACK CONVERTER: A power , parallel) with the load to give a constant voltage across the load. The control device is always conducting -
OCR Scan
power transformer tank calculation step down transformer power supply unit
Abstract: , overvoltage protection in hiccup mode, and large voltage range on the VDD pin. An isolated VIPer12A constant , consideration in designing this constant current power supply is the transformer. Since one to four LEDs can be , will be reflected back across the transformer and will in turn change the Vdd voltage to the control circuit and the peak Vds voltage across the MOSFET. The transformer must be designed with three limiting , Vf In order to keep the reflected voltage manageable, the transformer is designed for a turn STMicroelectronics
Original
AN1916 VIPER22A viper22a transformer design VIPER22A Application Note ST VIPER 22A VIPER 22A application notes VIPER22A not isolated 12/22A 22A-B
Abstract: Ferrite Cores For Transformer/Inductor EE, ER, EPC, EEM and T4 Series FEATURES · Miniature and , enables complete surface mounting even for a transformer having a large number of terminals. MATERIAL , , 200mT *2 500kHz, 50mT TDK CORPORATION 327 Ferrite Cores For Transformer/Inductor EE, ER, EPC , - Weight: 0.06g PARAMETERS Core constant Effective length Effective area Effective volume Weight Al , mm r -trn i L Input voltage Ein: 24Vdc Output voltage Eout: 5Vdc Temperature rise (Ambient -
OCR Scan
EEM12 tdk pc50 EE bobbin tdk TDK Ferrite Core PC44 core EE 25 transformer EE 60 bobbin ee series ferrite transformer BEM12 7-118G FEM12 PC44EEM12 PC50EEM12
Showing first 20 results.