500 MILLION PARTS FROM 12000 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

"cathode indication"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: indicators are designed for a variety of applications such as: · Main and remote power indication · Status Indication · Maintenance and warning indication · Instrumentation .and many more , brass Bi-color common cathode design Dialight Corporation 1501 Route 34 South · Farmingdale, NJ , . 2 Dimensions in inches [mm] All measurements are typical COMMON CATHODE COMMON CATHODE ... Dialight
Original
datasheet

2 pages,
519.74 Kb

606-2111-110 TEXT
datasheet frame
Abstract: metric indicators are designed for a variety of applications such as: · Main and remote power indication · Status Indication · Maintenance and warning indication · Instrumentation .and many more , brass Bi-color common cathode design Dialight Corporation 1501 Route 34 South · Farmingdale, NJ , in inches [mm] All measurements are typical COMMON CATHODE COMMON CATHODE FIG. 3 FIG. 4 ... Dialight
Original
datasheet

2 pages,
95.39 Kb

in6263 3 lead led bicolor - common cathode TEXT
datasheet frame
Abstract: metric indicators are designed for a variety of applications such as: · Main and remote power indication · Status Indication · Maintenance and warning indication · Instrumentation .and many more , brass Bi-color common cathode design Dialight Corporation 1501 Route 34 South · Farmingdale, NJ , FIG. 2 Dimensions in inches [mm] All measurements are typical COMMON CATHODE COMMON CATHODE ... Dialight
Original
datasheet

2 pages,
95.38 Kb

bi-color common cathode led 3 lead led bicolor - common cathode TEXT
datasheet frame
Abstract: indication • Status Indication • Maintenance and warning indication • Instrumentation , ) Housing Material: Chrome plated brass Bi-color common cathode design Dialight Corporation 1501 , FIG. 1 FIG. 2 Dimensions in inches [mm] All measurements are typical COMMON CATHODE COMMON CATHODE FIG. 3 FIG. 4 Part Number Color Voltage (VDC) Current (mA) Typ. Intensity ... Dialight
Original
datasheet

2 pages,
129.72 Kb

TEXT
datasheet frame
Abstract: Outline dimensions Anode Cathode Anode Cathode CL-L100 CL-L100 Series Tc measuring point (Side wall of the , state (smallest packing unit 200pcs) Affix the indication label which specified product name / amount , steps at the maximum in a manager. (max1,000pcs) Affix an indication label the same as primary packing to a cabinet. Last packing affixes an indication label the same as primary packing to a cabinet with appropriate corrugated cardboard and ships it. < Packing figure > plastic bag indication label ... Citizen Electronics
Original
datasheet

6 pages,
210.89 Kb

CL-L102-C3N CL-L102- CL-L102 CL-L100 CL-L100-C3N CE-P160 TEXT
datasheet frame
Abstract: Outline dimensions Anode Cathode Anode Cathode CL-L100 CL-L100 Series Tc measuring point (Side wall of the , packing unit 200pcs) Affix the indication label which specified product name / amount / lot number , in a manager. (max1,000pcs) Affix an indication label the same as primary packing to a cabinet. Last packing affixes an indication label the same as primary packing to a cabinet with appropriate corrugated cardboard and ships it. < Packing figure > plastic bag indication label indication label box ... Citizen Electronics
Original
datasheet

6 pages,
187.87 Kb

CLL100 CL-L102-C CL-L100 CL-L100-C3L CL-L102-C3L CE-P158 TEXT
datasheet frame
Abstract: PHILIPS [Z5Ö2S Cold cathode gas-filled BI-DIRECTIONAL DECADE SELECTOR TUBE. This tube has ten main cathodes, which are brought out separately. It gives visual indication and operates at speeds up , tube a dix cathodes, qui ont été sorties séparément. Il donne une, indication visuelle et , : arbitrary For visual indication the tube is viewed through the dome of the envelope.^, is aligned with pin , 300 (iA) = 186-196 V Pulse required for forced resetting to any main cathode Impulsion nécessaire ... OCR Scan
datasheet

6 pages,
221.2 Kb

INTERRUPTEUR impulsion kt 120 Tube TEXT
datasheet frame
Abstract: circuits employing the EM 1 it was often found difficult to obtain a satisfactory indication on weak signals as well as on strong ones, so that, if a sensitive indication is essential on weak signals as well , reached. On the other hand, if preference is given to a good, clearly . . . visible indication on Fig , –  Cathode 1'iC. 3 Construction of Philips Electronic Indicator EM 4. 144 strong transmitters, a suitable tapping being provided on the potential divider for this purpose, there will be hardly any indication at ... OCR Scan
datasheet

7 pages,
601.73 Kb

havc electronic tube light circuit diagram EM 4 Fluorescent Indicator Tube EM tube shadow detector circuits em4 tube TEXT
datasheet frame
Abstract: . 3 ^OjQioos 0O.57±002 -w - Cathode indication ir Cathode indication [ ID B , Fig. 7 Fig. 8 < 0.98±a06 t > Cathode indication L/ * 04.O±a2 31 S AN K E N ... OCR Scan
datasheet

3 pages,
84.78 Kb

TEXT
datasheet frame
Abstract: Z504S Z504S COUNTER AND SELECTOR TUBE Cold cathode gas-filled bi-directional 10 output selector tube. The Z504S Z504S gives visual indication and operates at speeds up to 5 kHz. QUICK REFERENCE DATA Maximum counting speed 5 kHz Supply voltage Vba 475 V Output, current 340 M A voltage 35 V Indication position , referred to the most positive supply potential to which any main cathode (not guide cathode) is returned , when switching on Vba < 550 V 1.0 Vba > 550 V 6.0 ms 1) ms 1) DISCHARGE AT REST ON A MAIN CATHODE ... OCR Scan
datasheet

8 pages,
265.82 Kb

S50-PS B13B 20MS s120p Z504S TEXT
datasheet frame