500 MILLION PARTS FROM 12000 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

"breaking unit"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: specifications Type Unit ZW32-12/ ZW32-12/ T400-12 T400-12.5 rated voltage rated current rated short circuit breaking , name of circuit breaker combined, it can act as breaking switch. The operating mechanism is CT23 type , Main technical specifications No. Type Unit 1 2 3 4 5 6 7 kV A KA KA KA KA KV , short circuit breaking current Rated short circuit switch-off on current (peak value) Rated peak , Rated short circuit breaking current breaking time Operating mechanism rated switch-on voltage ... Greegoo Electric
Original
datasheet

15 pages,
4683.91 Kb

EVS250 ABB Main Circuit breaker EVS630 CKJ20-630 ZKJ-350 CKJ5-600 contactor 1600 A CKJ5-80 vacuum circuit breaker CKJ5-125 vacuum breaker 220v ac circuit breaker ZN28-12 220 110 transformer ZW8-12 ZW8-12G 3 pole circuit breaker ABB ZW8-12 ZW8-12G JCZ5-12 ZW8-12 ZW8-12G CKJ5-250 ZW8-12 ZW8-12G abb SOFT STARTER CIRCUIT DIAGRAM ZW8-12 ZW8-12G ZW8-12 ZW8-12 ZW8-12G ZW8-12G TEXT
datasheet frame
Abstract: breaking capacity N Article No. www.siemens.com/ product?Article No. A A N PU (UNIT, SET , , high breaking capacity H Article No. www.siemens.com/ product?Article No. A A PU (UNIT , (ETU) Electronic Trip Unit with protection functions LI, LSI, LSING and LSIN(G), with or without , poles Rated operational voltage Ue V AC V DC Rated ultimate short-circuit breaking capacity , Breaking capacity Size I II Type 3WL11 3WL11 3WL12 3WL12 Breaking capacity N S N S H ... Siemens
Original
datasheet

72 pages,
4502.82 Kb

TEXT
datasheet frame
Abstract: Voltage Breaking Capacity 0.375 - 5A Super-Quick-Acting FF 1.05x0.55mm -32VDC -32VDC -35A 0.5 - , Quick-Acting F 12x5.2mm -63VAC -63VAC / 63VDC 63VDC -50A www.schurter.com Rated Voltage Breaking Capacity , -250VAC -250VAC / 300VDC 300VDC -500 - 1500A www.schurter.com Rated Voltage Breaking Capacity Web Reference , Breaking Capacity Web Reference or Type -250VAC -250VAC -35A SMD-FTT 73 For customer specific , Rated Current Characteristic Dimensions Rated Voltage Breaking Capacity 0.1 - 5A ... SCHURTER
Original
datasheet

223 pages,
24737.49 Kb

A12FA A12BK 7010.6310 schurter 380vac smps circuit diagram A12TD D8TD Ticomel J-STD-020D IEC 60269-2 IEC 60127-1 HA39 12.5A Fuses 202 MGA-S ftt 10A TEXT
datasheet frame
Abstract: technical documentation from your Rohm representative. Dimensions (Unit : mm) ICP-S0.5/S0.7/S1.0/S1.2/S1 , ICP-S Type Taping Symbol TN Basic ordering unit (pieces) 2000 ICP-S0.5 ICP-S0.7 ICP-S1.0 ICP-S1.2 Taping specifications (Unit : mm) ICP-S taping (TN) Electrode direction , Protection Elements Packaging specifications Dimensions (Unit : mm) Packaging type ICP-N20/N25/N38 ICP-N20/N25/N38 , Basic ordering unit (pieces) 3000 ICP-N20/N25/N38/N50/N70 ICP-N20/N25/N38/N50/N70 0.45±0.1 19.0 +1.0 -0.5 0.5 ... Original
datasheet

20 pages,
163.18 Kb

T104 ICPN5 ICP-N70 ICP-N50 ICP-N20 ICP-N25 Fuse n25 N50 Fuse ICP-N38 TEXT
datasheet frame
Abstract: goes out). Unit power-up U 3100 Resistance between terminals T1 and T2 1650 10 0 , AC15 : Cos = 0.3 6000 operations DC13 : L/R = 300 ms 6000 operations Breaking capacity Max. breaking current Max. breaking voltage Min. breaking current Maximum rate Mechanical life Electrical life Unit power-up U B.P. "reset" S2 Latching contact 3100 1650 Resistance between , pulse-string interference Pluggable into 11-pin base Fitting to DIN rail Class of protection IP 40 unit and ... Original
datasheet

4 pages,
57.51 Kb

IEC 34.11 AC12 relay vde 0435 VDE 0110 principle of relay in general DIN 44081 IEC 158-1 DIN 40050 Part 9 IEC 529 PTC probe IEC 255-3 TEXT
datasheet frame
Abstract: Short-circuit release with Normal Breaking Capacity release with High Breaking Capacity Technical Data Technical Data 2/11 Technical Data 2/12 2/9,2/10 release with Normal Breaking Capacity I-t , (Conventional MCCBs) with Standard Breaking Capacity High Breaking Capacity High Breaking Capacity , - Adjustable Overload & adjustable Short- circuit with standard Breaking Capacity Page Motor protection MCCBs circuit with high Breaking Capacity 3 & 4 3 & 4 Pole DM Pole Technical Data ... L&T
Original
datasheet

84 pages,
1475.81 Kb

DTH block diagram DTH circuit diagram TEXT
datasheet frame
Abstract: RXT Push button unit and Selector switch unit COMBIFLEX 1MRK 513 016-BEN 016-BEN Page 1 Issued May , button unit is intended for mounting on terminal bases. It occupies one seat. It is available with or , button front is possible. The selector switch unit is intended for mounting on terminal bases. It , . Technical data Table 1: Push button unit with built in pilot lamp Rated thermal current 6A Rated voltage 250 V Making capacity ac, cos = 0,7 Breaking capacity ac, cos = 0,7 24 V 48 V ... ABB Automation
Original
datasheet

2 pages,
177.56 Kb

016-BEN abb combiflex abb rk 795 pilot lamp 220 v ac to 24 v dc "Push button" RK 46 push to on button abb rk 216 RK 723 RK 795 001-aa push button RK 723 007 TEXT
datasheet frame
Abstract: connect a base unit. The input modules are positioned to the left of the base unit and the output , the majority of the devices are available with a variety of input voltage ranges. Every ESM-F unit , the device. A faulty unit can be replaced quickly. The faulty unit is simply removed and replaced with a new unit - that's it! Function is restored immediately. Automatic or manual start The base unit can be started either manually using a start button or automatically. SO SI SA Base ... EUCHNER
Original
datasheet

39 pages,
1946.41 Kb

esmba203 DC-12 DC-13 ESM-BA301 ESM-BA302 ESM-2H201 ESM-BA201 ESM-BA202 ESM-BT401 ESM-BA303 ESM-BT411 esm 107 ESM-BT421 esm-ba2 TEXT
datasheet frame
Abstract: , 1-8 A, High Breaking Capacity of 1500 A UL T Description Applications - High breaking capacity - High rated current - Pigtails optional - 3-phase applications , current Breaking Capacity Characteristic Mounting Admissible Ambient Air Temp. Climatic Category Material: Tube Material: Endcaps Material: Axial Leads Unit Weight Storage Conditions Product Marking , 60 °C, max. 70% r.h. , Type, Rated current, Rated voltage, Characteristic, Breaking capacity ... SCHURTER
Original
datasheet

3 pages,
259.31 Kb

TEXT
datasheet frame
Abstract: , 1-8 A, High Breaking Capacity of 1500 A UL F Description Applications - High breaking capacity - High rated current - Pigtails optional - 3-phase applications , current Breaking Capacity Characteristic Mounting Admissible Ambient Air Temp. Climatic Category Material: Tube Material: Endcaps Material: Axial Leads Unit Weight Storage Conditions Product Marking , €‰Â°C to 60 °C, max. 70% r.h. , Type, Rated current, Rated voltage, Characteristic, Breaking capacity ... SCHURTER
Original
datasheet

3 pages,
263.87 Kb

TEXT
datasheet frame