500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
PPG101A6 US Sensor RTD Platinum Sensor, 100ohm, Rectangular, Through Hole Mount
TDC-GP30YA ams ULTRASONIC FLOW SENSOR 40QFN
501830001 ams ULTRASONIC FLOW SENSOR 44TQFP
TDC-GP30YD-F01 ams ULTRASONIC FLOW SENSOR 32QFN
502030004 ams ULTRASONIC FLOW SENSOR 40QFN
502030007 ams ULTRASONIC FLOW SENSOR 40QFN

"FLUID Flow Sensor"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: . Information Required to Select a Flow Sensor: Each flow sensor has specific limitations regarding the , includes: Fluid Name: Maximum/Minimum Pressure1: Maximum/Minimum Temperature: Maximum/Minimum Flow Rate: Fluid Density (@ conditions of flow): Fluid Viscosity (@ conditions of flow): â'" If fluid density or , pipe run? Sufficient straight downstream pipe run? Percent Solids in Fluid: Are sensor materials , flow sensor can be found on pages Z-47 through Z-50. Z REF Omega Engineering Omega Engineering
Original
FL-1200 FL-75 FL-1500 FL-2000 FL-6000 FMA-1900
Abstract: ultrasonic wave propagation Turbidity of fluid: 10000 deg. (mg/R) or less State of flow: Axis-symmetric flow in pipe filled with fluid Fluid temperature: Small diameter sensor, ­ 40 to +100°C Small sensor , detecting the time difference obtained by the flow of fluid. Detector Upstream sensor Flow velocity , , fluid, sensor mounting method, type of sensor) up to 20 places and a maximum of 40000 data (time , DETECTOR SELECTION GUIDE Fluid temperature (°C) 200 High-temperature sensor Middle sensor 100 Fuji Electric
Original
FLD51 sensor FLC 100 JEMIS-032 grease G40M WEDGE FLOWMETER G40M ultrasonic flowmeter sensor FLD41 FLD32
Abstract: Measured fluid Water Karman vortex Detection type Flow rate measurement and setting range 0.5 to 4 , Sensor Unit PFW5 20 03 Output specification Flow rate range 04 20 40 11 Wiring , ) Flow direction 25 Series PFW Dimensions: Remote Type Sensor Unit for Water PFW504, PFW520 , mounting type Sensor 41.8 Blue 40.3 40 Brown Black 1 SMC FLOW SWITCH 2 3 , 1 2 For Water Digital Flow Switch/High Temperature Fluid Type Series PFW How to Order -
Original
PFW720 PFW740 PFW301 PFW7T-67 PFW321 smc fitting PFW704 PFW711
Abstract: to the plastic part of the main housing of the switch. 3. Monitor the flow direction of the fluid , explosion. 1. Check regulators and the flow adjustment valves before introducing the fluid. If pressure or flow rate beyond the specified range are applied to the switch, the sensor unit may be damaged , Temperature Fluid (Water 90°C) P. 16-11-26 Integrated display type Remote type Display unit Sensor , Output Note 4) specifications Measured fluid Flow rate measurement range Set flow rate range Flow SMC
Original
IFW510 IFW520 IFW550 PF2A PF2A751 1F33 PF2A710 PF2A721 PF2A711 PF2A510 PF2A521 PF2A511
Abstract: velocity. 4. Closing time of valves or other flow modifiers. The pressure increase in a fluid system , thru reducing the system fluid velocity. Often the GPM (gallons per minute) flow rate can be reduced , pointto pressure sensor to be protected (feet), c = Velocity of sound in system fluid (feet/second). , porous metal plug or filter in the pressure path, ora movable plunger restricting the flow rate. Sensor , REFERENCE AND APPLICATION DATA Pressure Sensors Protecting Pressure Sensor Diaphragm From -
OCR Scan
1-800-737-3360C
Abstract: PNP open collector 2 outputs Specifications Model Measured fluid Flow rate measurement range , Accumulated flow Operating fluid temperature Linearity Repeatability Temperature characteristics Current , Type Sensor Unit PF2A5 10 Flow rate range 1 to 10 l/min 10 5 to 50 l/min 50 10 to 100 l/min , ) Flow rate unit measured under the following conditions: 0°C and 101.3 kPa. Note 5) The sensor unit , Fixed SI unit Note) Nil M Mounting Symbol Flow rate range Type for sensor unit Flow rate SMC
Original
PF2W740 PF2W704 PF2A31 PF2A551 PF2A20 PF2A703H-69 ES100-54 PF2200 LV-1006 SK-81107 SF-02031 LT-2600
Abstract: technology ensures accurate flow measurement. Its temperature sensor compensation function provides , flow rate) Applicable cable outer diameter Power supply/outputs: 6 to 12 mm Temperature sensor , in buildings or shopping malls or it can be used in district heating/cooling applications. The flow rate is measured by an electromagnetic magnetic flow meter having field proven Yamatake technologies. It measures the flow rate of chilled water/water with glycol/hot water and calculates calorie Yamatake
Original
MCM10A JIS10K yamatake magnetic flow meter magnetic flow meter Yamatake Pt 100 sensor connection yamatake yamatake FL SS2-MCM100-0100 JIS20K ANSI150
Abstract: Sensor Products Division Phoenix, Arizona AN1573 Introduction Fluid systems, pressure and pressure , fluid movement or flow. As with a static system the static pressure acts equally in all directions. The , with the velocity or the flow of the fluid. The third pressure is total pressure and is simply the , pressures may be measured by tapping into the fluid stream perpendicular to the fluid flow. For a dynamic , pressures can be used to determine the fluid velocities and flow rates in dynamic systems. When measuring Motorola
Original
pitot sensor pitot static pressure sensor
Abstract: temperature sensor (FLD32) Type of flow; Well-developed turbulent or laminar flow in a full-filled pipe , flow rate output: When the flow direction of the fluid changes, then the flow rate can be measured in either direction by adding this function. When the flow of fluid reverses, measurement is done at an , Converter FLV: · Converter Upstream-side sensor · Manual Sensor FLW, FLD: t2 Flow velocity , to 2 points DETECTER SELECTION GUIDE Fluid temperature (°C) 200 High-temperature sensor (FLD3 Fuji Electric
Original
RG58A/U FLW122 FLW410 ultrasonic flowmeter ultrasonic flow meter FLD22 flowmeter FLW12 250VAC/250VDC EN50014
Abstract: Sensor Products Division Phoenix, Arizona AN1573 Introduction Fluid systems, pressure and pressure , is measured in a static system. Static pressure is independent of the fluid movement or flow. As with , flow of the fluid. The third pressure is total pressure and is simply the static pressure plus the , tapping into the fluid stream perpendicular to the fluid flow. For a dynamic system, steady­state , determine the fluid velocities and flow rates in dynamic systems. When measuring dynamic system pressures Motorola
Original
piezoelectric pressure sensor
Abstract: micro-electromechanical system and two pressure sensor compensating integrated circuits (ICs). The flow rate of a fluid , Maxim > App Notes > Sensor Signal Conditioners Keywords: flow sensor, electronic temperature compensation, pressure sensor, piezoresistive, miniature micro flow sensor, micro fluidic flow, integrated , APPLICATION NOTE 884 Miniature Flow Sensor Has Electronic Temperature Compensation Abstract: Measurement , fluids, the fluid under pressure is applied to the back of the sensor diaphragm (whose monocrystal-line Maxim Integrated Products
Original
MAX1458 MAX1452 MAX1463 AN884 APP884 fluid sensor block diagram
Abstract: to the plastic part of the main housing of the switch. 3. Monitor the flow direction of the fluid , explosion. 1. Check regulators and the flow adjustment valves before introducing the fluid. If pressure or flow rate beyond the specified range are applied to the switch, the sensor unit may be damaged , Temperature Fluid (Water 90°C) P. 16-11-26 Integrated display type Remote type Display unit Sensor , Output Note 4) specifications Measured fluid Flow rate measurement range Set flow rate range Flow SMC
Original
PF2W720 3-digit object counter circuit Yamatake 3000 flow elements 1.61.118 PF2A706H-28 PF2W300 D-107
Abstract: microelectromechanical system and two pressure sensor compensating integrated circuits (ICs). The flow rate of a fluid , Maxim > App Notes > SENSOR SIGNAL CONDITIONERS Keywords: flow sensor, electronic temperature compensation, pressure sensor, piezoresistive, miniature micro flow sensor, micro fluidic flow, integrated , APPLICATION NOTE 884 Miniature Flow Sensor Has Electronic Temperature Compensation Abstract: Measurement , fluids, the fluid under pressure is applied to the back of the sensor diaphragm (whose monocrystal-line Maxim Integrated Products
Original
Piezoresistive pressure sensors bio-chemical sensor medical flow sensor pressuresensor 55UL
Abstract: Topics Covered Turbulent Velocity or Flow Profile â'¢ The Flow Pioneers â'¢ Flow Sensor , Pioneers Flow Sensor Selection Accuracy vs. Repeatability A Flow Measurement Orientation ur , Orifice Target Meter (Best Case) Integral Orifice Flow Sensor Selection The purpose of this , common flow measurement mistakes is the reversal of this sequence: instead of selecting a sensor which , . data be filled in for each application: Fluid and flow characteristics: In this section of the table Omega Engineering
Original
ultrasonic 200 meters
Abstract: D6F-P MEMS Flow Sensor A Compact, High-accuracy Flow Sensor with Superior Resistance to , Information Model Applicable fluid (See note 1.) Flow rate range D6F-P0001A1 (Lead terminals) 0 , 25±5°C, and ambient humidity of 35% to 75%. 1 D6F-P MEMS Flow Sensor Characteristics , (typical) 2 8.0 g D6F-P MEMS Flow Sensor Connections/Dimensions (Unit: mm) I PCB Terminals , ) Red wire 180±10 1: Vcc 3 D6F-P MEMS Flow Sensor Safety Precautions WARNING The D6F OMRON
Original
D6F-P0010A1 D6F-P0010A2 D6F-P0010AM2 D6F-P0010A1/-P0010A2/-P0010AM2 A183-E1-01
Abstract: : 0.01 l/min. Fluid (0.1 l/min when the flow rate range is 25, 50, 100 l/min.) Air, N2, Ar, CO2 , between ANR and Nl/min for each fluid. [ANR] Indicates the flow rate converted to a volume under , l /min Sensor unit Monitor 4-channel flow monitor 0.4 to 4 1.8 to 20 4.0 to 40 , Principle Component Parts Series PFM3 Flow Sensor Monitor How to Order Specifications Analogue , .) Option 1 (Refer to page 2.) ( ): Fluid: CO2 Calibration certificate Flow adjustment valve SMC
Original
PFM711 PFM725 PFM710 PFM750 Silicon Fluid MS 550 PFM511 EUS100-63B-UK SF-02231 LT-04123 SLO-8210
Abstract: MEMS pressure sensor with analog output Air. Other gas/fluid, please inquire. 0 to 4.9 kPa 0 ­ 1.25 , pressure sensor with pulse count output Air. Other gas/fluid, please inquire. Varies by type (0 to 5.88 , 1.18) · Solid state MEMS pressure sensor with frequency output Air. Other gas/fluid, please inquire , Applicable fluid Flow Range (Output Voltage = 1­ 5VDC) Supply voltage Temperature range 15 H x 20 D , (in) Features Applicable fluid Pressure range Output voltage Output frequency Supply voltage OMRON
Original
MEMS pressure sensor MICRO USA Pressure Sensor fluid PRESSURE SENSOR tilt sensor 0.1 mems sensor feature Y0I-E-02 JB301-E3-01
Abstract: single paddle Sensor/Switch is specially designed for monitoring minimum/maximum values of flow. The , pluged in Standards EMI EN 50081-1, 50082-2, 61010-2 Fluid Control Systems Flow - On/Off Control Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control Ordering table for SE10 (electronic SE10 and sensor fitting S010 build the 8010) ON/OFF Flow Control System, mechanical, magnetic , dimensions [mm] Dimensions [mm] Magnetic paddle flow switch type 8010 Range Fitting Fluid -
Original
flow sensor switch PLC material fluid flow sensor 15DN DIODE water flow sensor dn 32 DN25 DN40 001-GB/
Abstract: vortex flow meter with a piezoelectric sensor, the sensitivity of the ULTRA Vortexor is greater. Also , second sensor maintains flow rate measurement. · Expand Minimum measurable flow rate The minimum , of rate accuracy (Note 4) Size Flow rate with ±0.5% of rate accuracy (m3/h) (mm) Process fluid , fluid flows from bottom to top and always fills the pipe. flow rate by using the following expression , . Match the flow direction of the fluid with the direction 25mm Flow rate = kinetic viscosity X 0.2834 + Yamatake
Original
SS2-VRX100-0100 vortex flow meter Piezoelectric vortex flow meter ultrasonic distance sensor waterproof VRX10A ultrasonic water flow meter Vortex flowmeter JPI/ANSI150 JPI/ANSI300
Abstract: product failure. 5. Install the Sensor so that the fluid flows in the direction indicated by the arrow on the Sensor. Correct measurements cannot be obtained if the fluid flows in the wrong direction. 6 , dust or dirt, may enter into the Sensor and partially or completely block the flow path. If this occurs , into the Sensor and partially or completely block the flow path. If this occurs, the Sensor may not be , D6F Flow Sensors Technical Information Precautions for Correct Use Precautions for Safe OMRON
Original
A0037G AN METHANE SENSOR D6F-03A3 iso 3601-1 liquefied flammable gas sensor methane X305-E-1
Showing first 20 results.