500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

"Diaphragm Pressure Gauge"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: element, which constitutes a strain gauge, is ion implanted on a thin silicon diaphragm. Applying pressure to the diaphragm results in a resistance change in the strain gauge, which in turn causes a change in the output voltage in direct proportion to the applied pressure. The strain gauge is an integral part , expansion of the strain gauge and the diaphragm. The output parameters of the strain gauge itself are , ), and the pressure that stresses the diaphragm is applied at a right angle to the current flow. The Motorola
Original
strain gauge MPX100A mpx51* pressure sensor STRAIN GAUGE motorola pressure sensor strain gauge STRAIN GAUGE silicon
Abstract: pressure. The resistive element, which constitutes a strain gauge, is ion implanted on a thin silicon diaphragm. Applying pressure to the diaphragm results in a resistance change in the strain gauge, which in , gauge is an integral part of the silicon diaphragm, hence there are no temperature effects due to differences in thermal expansion of the strain gauge and the diaphragm. The output parameters of the strain , networks are necessary. ETCHED DIAPHRAGM BOUNDARY TRANSVERSE VOLTAGE STRAIN GAUGE RESISTOR 1 Motorola
Original
atmospheric pressure sensor MPXH6101A6T1 MPX4200A
Abstract: -43 PRESSURE GAUGES Diaphragm seals shown with model PGH-45L-200 Process Gauge G DIAPHRAGM , DIAPHRAGM PRESSURE SEALS FOR ASSURED PROTECTION AND MEDIA COMPATIBILITY Seals From 220 , of the Liquid Fill in the Pressure Seal Through Movement of the Diaphragm Transmits Process Pressure Directly to the Pressure Instrumentation OMEGA® Diaphragm Pressure Seals afford greater , housing. OMEGA® Diaphragm Pressure Seals are available to be used in conjunction with the following Omega Engineering
Original
2-302-TT- 2-CG-150-RF 2-302-TT-1 150-RF PGT-45L-100 1-100-PM-1
Abstract: PRG 101 DIMENSIONS: IN (MM) Bleed orifice Pilot diaphragm Max pressure stop locknuts Tension nut Vent Control diaphragm 1.73(44) Relief valve Regulated pressure , Regulated pressure .55(14) Inlet port 1/4" NPT Gauge port 1/4" NPT 2.12(54) .44(11.5)required , Pressure Gauge (PRG501): Phosphor bronze bourdon tube Process Connection: 1â"4 NPT female (pneumatic , PRECISION PRESSURE REGULATORS PRG101/501 Series 95 $ Basic Unit ß Two 1â"4 NPT Omega Engineering
Original
PRG101 PRG101-25 PRG101-60 PRG101-120 PRG501-X15 PRG501-30
Abstract: 200 / 220, AMD 210 / 230 with Attached Remote Seal for Gauge Pressure, Absolute Pressure and Level , / 220, AMD 210 / 230 with Attached Remote Seal for Gauge Pressure, Absolute Pressure and Level 15-5.44 , Transmitter AMD 200 / 220, AMD 210 / 230 with Remote Seal for Gauge Pressure, Absolute Pressure and Level , (AMD 220 for Gauge Pressure / Level) 0.60 mbar (6 kPa) 0.400 mbar (40 kPa) Order No. V155 AE , for Gauge Pressure / Level) 0.2,5 bar (250 kPa) 0.16 bar (1600 kPa) 0.40 bar (4 MPa) 0.100 -
Original
D-32425 abb pressure transmitter ASD-800 pressure transmitter ASD-800 Contrans P ASD 800 Contrans Transmitter ASD 800 ASD 810 800/ASD
Abstract: element, which constitutes a strain gauge, is ion implanted on a thin silicon diaphragm. Applying pressure to the diaphragm results in a resistance change in the strain gauge, which in turn causes a change in the output voltage in direct proportion to the applied pressure. The strain gauge is an integral part , expansion of the strain gauge and the diaphragm. The output parameters of the strain gauge itself are , ), and the pressure that stresses the diaphragm is applied at a right angle to the current flow. The Motorola
Original
Piezoresistor
Abstract: applied pressure. The strain gauge is an integral part of the silicon diaphragm, hence there are no temperature effects due to differences in thermal expansion of the strain gauge and the diaphragm. The output , . Selection versatility includes choice of: Applying pressure to the diaphragm results in a resistance change , element, which constitutes a strain gauge, is ion implanted on a thin silicon diaphragm. ACTIVE ELEMENT s- s- ETCHED DIAPHRAGM BOUNDARY TRANSVERSE VOLTAGE STRAIN GAUGE RESISTOR s+ VOLTAGE TAPS Freescale Semiconductor
Original
strain gauge water level sensor freescale tire pressure sensor industrial pressure sensor circuit infusion pump pressure transducer oil pressure sensor
Abstract: element, which constitutes a strain gauge, is ion implanted on a thin silicon diaphragm. Applying pressure to the diaphragm results in a resistance change in the strain gauge, which in turn causes a change in the o u tpu t vo lta g e in d ire c t p ro p o rtio n to the a pplied pressure. The strain gauge is an , its patented strain gauge design. Unlike the more conventional pressure sensors which utilize four , : Devices are available for differential, absolute, or gauge pressure measurements. TEMPERATURE (°C -
OCR Scan
MPX700 water level mpx5050 bio-medical temperature sensor MPX 1,45 psi mpx7000 biomedical pressure sensor 300mmhg MPX10 MPX50 MPX100 MPX200 MPX906
Abstract: pressure as well as for positive and negative gauge pressure. Common feature is the use of dry , ceramic diaphragm. This unit forms a plate capacitor changing under pressure. The dry , range Gauge pressure limit 1) Low pressure limit Gauge pressure 0 . 0,1 bar 2,5 bar , process connection! VEGABAR 20, 21, 24 Low pressure limit Gauge pressure 0 . 0,1 bar 1) Gauge pressure limit 1) 25,0 bar Min. pressure 2) Zero Span Zero elevation Turn down -
Original
2526-Form D IK pressure gauge USS pn 150 relay Ex-94 2526-Form C vegabar 52 B-1731 F-67151 NL-3800 CH-8330
Abstract: part throttle. FUEL PRESSURE GAUGE PORT A 1/8 NPT port is tapped into the side of the Mallory regulator housing. The port is supplied from Mallory with a plug. If a fuel pressure gauge is used, the , JAM NUT VACUUM PORT GAUGE PORT See Figure 2 If the regulator develops a leak or the pressure , FORM 1459-01 (REV. B) 7/99 INSTALLATION INSTRUCTIONS ® FUEL PRESSURE REGULATOR Part No. 4213 INSTALLATION Mallory's 4213 Adjustable Fuel Pressure Regulator is designed to be a bolton Mallory Ignition
Original
Abstract: /GM/GG/GJ/GN for gauge pressure, Model 265AC/AM/AG/AJ/AN for absolute pressure, with direct mount , Transmitters 265Gx, 265Ax SS/265GC/AC-EN_03 Model 265GC/GM/GG/GJ/GN for gauge pressure, Model 265AC/AM/AG/AJ , for gauge pressure, Model 265AC/AM/AG/AJ/AN for absolute pressure, with direct mount seal 13.1 , /GN for gauge pressure, Model 265AC/AM/AG/AJ/AN for absolute pressure, with direct mount seal 1 , Transmitters 265Gx, 265Ax SS/265GC/AC-EN_03 Model 265GC/GM/GG/GJ/GN for gauge pressure, Model 265AC/AM/AG/AJ ABB Automation
Original
harting catalog han 8U 265GC 2526-Form E data sheet IC 4435 harting han 8U 265Gx 2600T 3KXP200003R1001
Abstract: Diaphragm seals D912 Flanged chemical seals Main features Pressure range from 10 mbar , steel 1.4404 NACE Applications Pressure, level or flow measurement. Mounted on differential, absolute or gauge pressure transmitters. Process technic Hydraulic Pneumatic Refrigeration Water , Gauge or differential pressure: min. 10 mbar Absolute pressure: min. 50 mbar Flanges EN 1759-1 , OD3/8" â'¢ Bolts ASTM A193 B7M / A194 2HM â'¢ Gauge and differential pressure: minimum 10 mbar â Baumer
Original
siemens F HVAC EN10088-3 EN/2013-02-04
Abstract: filter regulator can be directly mounted on the transmitter, with or without pressure gauge, and , specification MR0175, latest revision Pressure gauge -with with 1 2 3 4 5 6 7 8 9 02 10 , Specification sheet Deltapi N Series Pneumatic Transmitters Model NAD Differential pressure transmitter GENERAL CHARACTERISTICS The blind type differential pressure transmitter, mod. NAD, is used to measure and convert a differential pressure value into a proportional pneumatic signal. The -
Original
zero elevation and zero suppression ABB pressure regulator ISA differential pressure transmitter ISA pressure filter regulator NAD 140 ABB Deltapi K series
Abstract: 50 DN: Nominal diameter, PN: Nominal pressure in bar Min. M.R.: Minimum measuring range in bar for a Ø 100 mm pressure gauge. Maximum pressure according to the PN of the ï¬'ange and its , measuring range in bar for a Ø 100 mm pressure gauge. Maximum pressure according to the PN of the ï¬'ange , for a Ø 100 mm pressure gauge. Maximum pressure according to the PN of the ï¬'ange and its , diaphragm of the same material (D824, D825) Fluid temperature from -60 to +400°C D820 DN ≤ 25 mm Baumer
Original
DN 25 pn 40 rf flange D820-824-825 D425/D435 EN1092-1 EN/2012-02-07
Abstract: filter regulator can be directly mounted on the transmitter, with or without pressure gauge, and , specification MR0175, latest revision Pressure gauge -with with 1 2 3 4 5 6 7 8 9 02 10 , Specification sheet Deltapi N Series Pneumatic Transmitters Model NAD Differential pressure transmitter GENERAL CHARACTERISTICS The blind type differential pressure transmitter, mod. NAD, is used to measure and convert a differential pressure value into a proportional pneumatic signal. The ABB Group
Original
MR-01-75 Deltapi K series abb deltapi n ABB Deltapi K aisi 316l NAD 208
Abstract: D821 Flanged diaphragm seal with enlarged diaphragm Main Features Â"Â" Pressure range from , diaphragm seals with flanged process connection and enlarged diaphragm are used to protect pressure gauges , low pressure ranges, despite the small size of the flange. Different diaphragm materials can be , 1.4435 (AISI 316L) Option: Hastelloy (see ordering details on page 3) Diaphragm Maximum pressure , ) Minimum pressure ranges depending on diaphragm diameter Ø M 1) Ø M 2) (mm) DN63 DN100/150/160 Baumer
Original
B16-5
Abstract: gasket seat. A remote seal can be selected with required diaphragm material (refer to high pressure , Data Sheet DS/266XDH-EN Model 266DDH Differential Model 266HDH Gauge Model 266NDH Absolute 2600T Series Pressure Transmitters Engineered solutions for all applications Base accuracy from , compliance to sound engineering practice (SEP) Model 266DDH Differential Model 266HDH Gauge Model , transmitters which include on high pressure measuring side, a direct mount seal which is integral to the ABB Automation
Original
NACE ISO DC200 silicone oil baysilone M5 ball valve PN 16 S26WA S26FA C-276 C-2000 DC200 DC704 3KXP200017R1001
Abstract: element, which constitutes a strain gauge, is ion implanted on a thin silicon diaphragm. Applying pressure to the diaphragm results in a resistance change in the strain gauge, which in turn causes a change in the output voltage in direct proportion to the applied pressure. The strain gauge is an , thermal expansion of the strain gauge and the diaphragm. The output parameters of the strain gauge itself , pressure that stresses the diaphragm is applied at a right angle to the current flow. The stress Motorola
Original
MGS1000 MGS1100 MGS1200 MPX2052D MPX2050DP amplifier circuits strain gauge amplifier 102 biomedical sensors MMAS40G MMAS40GWB
Abstract: a bright loop-powered LED display. Diaphragm Pressure port Cross-sectional view of the LP 1000 , Pressure Measurement Operating Ranges: Mechanical Characteristics Sensor Housing: Measuring Diaphragm , % - F.S. 1 ± 0.25% - F.S. Code Pressure Reference 0 Wet/wet Gauge 1 Wet/wet Differential Code Pressure , LP 1000 Series Ultra low pressure sensor The LP 1000 Series pressure transmitter is designed , pressure ports simplify sensor access, greatly reducing calibration time and costs associated with cGMP GE Industrial Systems
Original
d7517 Diaphragm Pressure Gauge U10-U99 B10-B99 LP1110B25WX4C2DAN5 D-75179
Abstract: OVERVIEW The Smart Pressure Transmitter model PTG is a high- performance, highly reliable gauge pressure , Gauge pressure transmitter: Screw connection type with SFC communication Gauge pressure transmitter , pressure transmitter: Screw connection type (flush) with SFC Communication Gauge pressure transmitter , Selection Basic model number Product description Gauge pressure transmitter: Flange mount type with SFC communication Gauge pressure transmitter: Flange mount type with SFC/ HART communication Yamatake
Original
PTG71 TDCS3000 PTG71G SUS316L ptg72g PTG71B HART 275 ptg72 SS2-PTG300-0100 PTG72 3000X
Showing first 20 results.