500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
POWEREST Texas Instruments Power Estimation Tool (PET)
WM8325GEFL/V Cirrus Logic Power Management Circuit, CMOS
WM8321GEFL/V Cirrus Logic Power Management Circuit, CMOS

"DC Power Connector" 2.5 MM

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: Connector (CON1) · · · DC Power Connector 2.5 mm Jack Socket ­ Centre Positive DC Power Lead , .9 1.5.4 DC Power Input Connector ( 1.5.5 DC Power Cable Specification , .35 3.0 Programmer / Target System Power Supply Scenarios + Standalone Mode Programming Instructions , System Power Supply Schematic .38 3.3 Earthing requirements Equinox Technologies
Original
eeprom programmer schematic ATMEGA 8A eeprom programmer schematic diagram ZW0102 ZENSYS Z-Wave Application Programming Guide
Abstract: ) · · · DC Power Connector 2.5 mm Jack Socket ­ Centre Positive DC Power Lead supplied with , .9 1.5.4 DC Power Input Connector ( 1.5.5 DC Power Cable Specification , .35 EPSILON5 MKII Programmer - User Guide V1.12 ­ 1st August 2007 i 3.0 Programmer / Target System Power , .37 3.2 Programmer / Target System Power Supply Schematic Equinox Technologies
Original
ZW0301 ZW0301 Application Programming Guide 8051 programmer schematic with keypad programming AVR using Labview Z-Wave Single Chip ZW0201
Abstract: , attenuation value and power level. o Express shipment available on most models. o o o o o , Loads Terminations . . . dc-50 GHz, 1 to 25 Watts Frequency Range (GHz) Average Power (Watts) Peak Power (kW) SWR Connector Type Page No. ) 1404N dc-18.0 1 1 1.02-1.08 , Range (GHz) Average Power (Watts) Peak Power (kW) SWR Connector Type Page No , 500 Watts Frequency Range (GHz) Average Power (Watts) Peak Power (kW) SWR Connector Aeroflex / Weinschel
Original
M1437 weinschel 150 watt model m1428 sma connector power rating n CONNECTOR weight F1428 RS3016 MIL-D-39030 MIL-C-39012
Abstract: fine thread M8 x 1 mm · Normally open/normally closed function · Cable or connector · High , Drawing dimensions in inches (mm) 13 LED M8x1 1.6 (40.2) 0.2 (4.8) LED M8x1 1.4 (36.2 , to 55 Hz, 1 mm -13.158°F (-25.70°C) Brass, nickel-plated, plastic 4 Nm PVC, 3 x 0.14 mm2 Operating voltage Ub Ripple Upp Voltage drop Ub Power consumption (without load) Continuous current Ia , Tightening torque Connection cable Selection Table Sensing Installation range Sn in metal in (mm -
Original
IM08-01B-N-ZW0 IM08-1B5PS-ZWK IM08-02BPS-ZT1 IM08-1B5PS-ZTK IM08-04NPS-ZT1 04NN
Abstract: : Output Power: CE-1077 PS-LD0101-x-yyy PS-LD0301-x-yyy PS-LD0302-x PS-LD0304-x PS-LD0305-x RGB , : Lamps: Output Power: PS-DA0136-01 PS-DA0136-02 CXA-0323 CXA-L0505-NJL CXA-L0512-NJL , Product: Lamps: Output Power: PS-DA0125-02 PS-DA0125-03 PS-DA0125-04 PS-DA0125 , PS-DA0203-03 Dual PS-DA0224-10 Dual PS-DA0253-01 Dual PS-DA0253-01-E-B Dual Output Power: 6 Watt , 58 59 59 60 Product: Lamps: Output Power: PS-DA0253-02 PS-DA0253-023 PS-DA0253 Power Systems
Original
PS-LD0101- PS-LD0301- PS-LD0302- PS-LD0304- PS-LD0305- PS-LD0602-
Abstract: .DC . MM 08 . 120 MM 12 . 122 MM 18 . 124 MQ 10 . , .NAMUR . MM 12 . 128 MM 18 , real sensing range or in mm. Minimum load current Smallest load current that must flow with , identical conditions. Residual current Ir The residual current is used to supply power to the 2 SICK Optic Electronic
Original
IM08-1B5PS-ZC1 sensor IM18-08BPS-ZC1 SICK MAKE IM08-1B5PS-ZT1 IM04-0B6PS-ZU1 zck m1 IM12-02BPS-ZC1
Abstract: . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . 18 mm Threaded Barrel 1 3 4 4 4 5 5 Output LED (Red) Power LED (Green) No Sensor Is Easier to Use The SM Series , intended for use in human safety applications. Highly visible LED indicators for power, output and , to fit in tight spaces Multiple mounting options including industry standard 18 mm threads Reverse , visible from 360°. In addition to LEDs for power and output status indication, the SM features a third EATON
Original
E65-SMSD200-GLD E65-SMSD200-HD E65-SMPP050-HLD E65-SMPR3-HL SHOCK SENSOR 083
Abstract: (Red) Power LED (Green) TargetLockTM LED (Orange) Gain Adjustment AC/DC Operation Contents Overview , Dimensions . . . . . . . . . . . . . . . . . . . . 1 3 4 4 4 5 5 18 mm Threaded Barrel Compact Size , Highly visible LED indicators for power, output and TargetLockTM TargetLockTM simplifies setup and , mounting options including industry standard 18 mm threads Reverse polarity, overload and short circuit , 360°. In addition to LEDs for power and output status indication, the SM features a third LED that is EATON
Original
05E-17
Abstract: detection using teach mode M8 M12 M18 2.5 mm M30 4 mm 8 mm 15 mm Usable sensing distance S (mm) flush mountable / non flush mountable 0.2 0.3.2 0.6.4 0.12 Fine adjustment zone (mm) flush mountable / non flush mountable ­ ­ ­ ­ Suitability for flush , Connection Pre-cabled, PvR (2 m) Dimensions (mm) Ø x L or W x H x D M18 x 60 M30 x 60 , (mm) Ø x L or W x H x D 3-wire PNP NO function XS612B1PAM12 XS618B1PAM12 XS608B1PBM12 -
Original
XSA-V11373 XSA-V11801 XSAV12801 XSAV11801 XSA-V12373 XZCP1141L5 XS612B1PAL2 XS618B1PAL2 XS630B1PAL2 XS608B1PBL2 XS612B1PBL2 XS618B1PBL2
Abstract: ) 6.00" (152 mm) 1.50" (38 mm) Power On Optical In 104xx Outline Diagram (Dimensions are in , chassis and power supplies. Electronics within flange-mount and plug-in receivers provide a reverse bias for the photodiodes and monitor the dc level of the optical input power, thus providing a fully , Flange-mount Plug-ins Storage Temperature Range: Modules and Flange-mount Plug-ins Input Power: 2510A/B, 2515A.B, 1516A/B/C 2518A/B Maximum Power for 60 s: 2510A/B, 2515A.B, 1516A/B/C 2518A/B dc Current Lucent Technologies
Original
Lucent Technologies fiber optics cable 10456B microwave receiver 4510A Lucent receiver Lucent photodiodes 30L-15P-BA DS00-305OPTO
Abstract: . Power source and output 7. Sensing distance Numeral: Sensing distance: e.g. 02=2 mm, 16=16 mm 10 , NC 27 (40) Pre-wired 49 (62) 27 (43) M12 connector 49 (65) Shiel2.0 mm ded M8 connector (3-pin) 27 , (65) 4.0 mm M8 connector (3-pin) 27 (39) 49 (61) 27 (39) 49 (61) M8 connector (4-pin) M8 Pre-wired , Shielded 4.0 mm M8 connector (3-pin) Brass*3 56 (70) 34 (48) Brass*3 56 (70) 34 (48) Brass *3 , Nonshielded 8.0 mm M8 connector (3-pin) Brass*3 56 (70) 34 (48) Brass*3 56 (70) 34 (48) Brass *3 -
Original
E2A-S12 DIODE M5J steel st37 E2A-M30LS15-WP-B3 E2A-M12KN08-M3-C1 m5j diode E2A-S08KS02-WP-B1 E2A-S08KS02-WP-C1 E2A-S08LS02-WP-B1 E2A-S08LS02-WP-C1 E2A-S08KS02-M1-B1 E2A-S08KS02-M1-C1
Abstract: Shielding - NC M5 1 mm DC NPN NO 4 dia. 0.8 mm Power supply 3 dia. 0.6 mm , 54 × 1 mm Response frequency *2 1.5 kHz 1 kHz 0.1 kHz Power supply voltage , stopping. Reduced wiring, fewer resources, and low power consumption contribute to environmentalism. · , : Self-diagnosis, : Different frequency and self-diagnosis, -: Not listed 2-Wire Models M12 3 mm No Shielded Yes M18 7 mm No Yes DC M30 10 mm No Pre-wired model with standard 2-m cable OMRON
Original
E2E-X8MD15 E2EX5ME1 XS2W-D421-BY1 e2e-x7d1s E2EX5MF1 ZCAT2035-0930A
Abstract: M5 1 mm Power supply NO 4 dia. 0.8 mm DC NPN M12 pre-wired smartclick connector , resources, and low power consumption contribute to environmentalism. · Wiring work and amount of copper , frequency and self-diagnosis, -: Not listed 2-Wire Models M12 3 mm No Shielded Yes M18 7 mm No Yes DC M30 10 mm No Pre-wired model with standard 2-m cable Pre-wired model with , M12 8 mm NO - - @ @ - M18 14 mm NC Yes - OMRON
Original
E2E-X10E1 2M E2E-X5E1-M1 e2e-x7D1-N 2M E2E-X7T1 e2e-x4MD1 2M e2e-x3D1-N 2M
Abstract: Power supply M8 connector M8 2m M12 3 mm Yes Yes No NO NC NO NC NO NC NO NC NO NC NO NC NO , Dimensions reference chart Refer to page 30. Shielding Power supply M8 connector 3 dia. 0.6 mm 4 , E2E-X10T1 10 mm ±10% M30 Power supply voltage 24 to 240 VDC (20 to 264 VDC) (operating voltage range) *2 , to keep the line from stopping. Reduced wiring, fewer resources, and low power consumption , conventional connector pin assignments on page 9. Shielded Yes M18 7 mm No Yes M30 10 mm No M8 4 mm DC OMRON
Original
E2E-X5f1 2m E2E-X10ME1 E2EX1R5Y2 X5MF
Abstract: performance irrespective of the installation method (flush, non flush). > Sensor/object distance 60 mm , 20 mm (0.79") > Specific products for particular applications b Hyde Park Ultrasonic sensors , ') 2 m (6.6') Thru-beam 15 m (49') 15 m (49') Mounting (mm) M18 x 1 M18 x 1 Case M (metal) P (plastic) / Dimensions (mm) Ø x L or W x H x D P / M18 x 64 M / M18 x 64 Common , programmable, NO/NC with time delay ­ ­ ­ LED output state indicator () / power on LED () ­ Schneider Electric
Original
Telemecanique XSAV11801 telemecanique xsav12801 XURK0955D telemecanique OSIRIS xuk0arctl2 schneider XUX0ARCTT16 Telemecanique XSC SM906A-420000S SM956A-420000 SM956A-420000S SM906A-422000 SM906A-422000S SM956A-422000
Abstract: A 44 54 84 55 56 83 A 69 75 Average Peak Frequency Power Power Range (Watts) (kW) (GHz) 1 2 2 2 2 2 , Frequency Power Power Range (Watts) (kW) (GHz) 50 5 dc-8.5 Nominal Attenuation Value (dB) 3, 6, 10, 20, 30 , GHz 26.5 GHz 40 GHz Attenuator Section Guide: Power Handling / Frequency / Connector Type 16 , attenuators? Weinschel low power fixed attenuators feature a combination of advantages over other designs:* 1 , , fired at 950°C for superior long term stability over temperature, power and time. The attenuator element Weinschel
Original
DESC 94008 Weinschel Model-1 MIL-A-3933
Abstract: - M12 2 mm Shielding - NC M5 1 mm DC NPN NO 4 dia. 0.8 mm Power , sensing object Iron, 8 × 8 × 1 mm Response frequency 25 Hz Power supply voltage (operating , Iron, 3 × 3 × 1 mm Iron, 5 × 5 × 1 mm Response frequency * 2 kHz Power supply voltage , resources, and low power consumption contribute to environmentalism. · Wiring work and amount of copper , frequency and self-diagnosis, -: Not listed 2-Wire Models M12 3 mm No Shielded Yes M18 7 mm OMRON
Original
c200h id212 OMRON C200H E2E-X1C1 947-5-2 omron E2E-X1R5F1-M1 OMRON C200H Id212
Abstract: chart Refer to page 29. Shielding Power supply M8 connector M8 2m M12 3 mm Yes Yes No , 29. Shielding Power supply M8 connector 3 dia. 0.6 mm 4 dia. 0.8 mm M5 1 mm 5.4 dia. 1 mm , Connector Models.) 0.3M M Meaning Remarks Example: R6: 0.6 mm 1R5: 1.5 mm D Power supply and , wiring, fewer resources, and low power consumption contribute to environmentalism. · Wiring work and , conventional connector pin assignments on page 9. Shielded Yes M18 7 mm No Yes M30 10 mm No M8 4 mm DC OMRON
Original
Abstract: (0.47) A D Dimensions are in mm (in.) MOD NET 2198-P031 DC-bus Power Supply is Shown 2 , corner-grounded input power 3000 m (9843 ft) during transport Vibration 5â'¦55 Hz @ 0.35 mm (0.014 in , power supplies. DC-bus Power Connector Example DC-bus Link, 85 mm DC-bus Link, 100 mm (seated , Single Axis Inverter, 85 mm DC-bus Power Supply (1) DC-bus links latch on both sides when inserted , power T-connector â'¢ Bus-bar connectors, 100 mm, quantity 2 Illustration Control Power Input Allen-Bradley
Original
10SP 010 thermistor 10SP 005 thermistor 15SP thermistor 2090-XXNFMF-S 20SP 012 thermistor 2198-TCON-24VDCIN36 GMC-SG001 1756-L7 RA-DU002 GMC-TD003G-EN-P GMC-TD003F-EN-P
Abstract: 3.5 mm power divider, DC to 26.5 GHz 2.4 mm power divider, DC to 50 GHz 11667B 11667C 3.5 mm power splitter, DC to 26.5 GHz 2.4 mm power splitter, DC to 50 GHz 4 Storage See also , Oscilloscope channel connection (NMD/3.5 mm) 1143A Power cord Probe amplifier connection N5477A , Probe adapter 1 85130-60010 2.4 to 3.5 mm adapter 1 1143A Probe power supply 1 , Connectors Product Probe power 3.5 mm 54754A Yes 2.4 mm 1.85 mm Optical f/f CS Agilent Technologies
Original
N1027A-45A N1027A-1PB 11901C N9398G N5520A N5520B
Showing first 20 results.