500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
TPD4F003DQDR Texas Instruments Four-Channel EMI Filter With Integrated ESD Protection 8-WSON -40 to 85
TPD4F202YFUR Texas Instruments Four-Channel EMI Filter With ESD Protection for LCD Display 10-DSBGA -40 to 85
TXS0206YFPR Texas Instruments MMC, SD Card, MemoryStick Voltage-Translation Transceiver With ESD Protection and EMI Filtering 20-DSBGA -40 to 85
TXS0206-29YFPRB Texas Instruments MMC, SD Card, MemoryStick Voltage-Translation With ESD Protection, EMI Filtering, and 2.9 V LDO 20-DSBGA -40 to 85
TXS0206-29YFPR Texas Instruments MMC, SD Card, MemoryStick Voltage-Translation With ESD Protection, EMI Filtering, and 2.9 V LDO 20-DSBGA -40 to 85
ISL32705EIBZ Intersil Corporation Low-EMI Isolated Full-Duplex RS-485 Transceiver; 24; Temp Range: -40° to 85°C

"Contact Protection of Electromagnetic Relays"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: electromechanical relays) and at the range of the rated contact load they offer highly reliable switching , protection While using electromagnetic relays in electric circuits, it should be borne in mind that coils , overvoltage protection modules of M series may be used with the relays and then the modules are mounted in , "-". Ordering codes of the overvoltage protection elements integrated in the relays (as add-on , relays successfully. The only theoretical limitations are the dimensions of relays, electromagnetic Relpol
Original
Feme Relays feme relay Feme Relays 001 RELAY feme reed feme reed relays feme relay 001 26 10 UL508
Abstract: motors. The DCR100 can also be used to switch AC circuits using external relays. An added benefit of , (Over Temperature Protection) â'¢ Relays Switchable Using Maretron DSM150, DSM250, N2KView®, or , Classification Degree of Protection Operating Temperature Environmental Comment 3.50â' x 4.20â' x , DCR100 Direct Current Relays Maretronâ'™s DCR100 contains 6 Direct Current (DC) relays, each capable of switching up to 10 amps. The DCR100 connects directly to an NMEA 2000® network, so Maretron
Original
DCR100-01 IEC60945-8 2-100H
Abstract: RM84 / RM85 / RM87 Miniature Electromagnetic Relays â'¢ Miniature dimensions â'¢ Cadmium - free , versions with the increased dielectric strength of the contact clearance â'¢ IP67 flux proof, water proof and sealed cover protection (For IP40 unsealed, contact Altech) E105728 RM84 RM85 RM87 , PN-EN 116000-3 30 g 10 g 10.150 Hz max. 270 °C max. 5 s Contact Data No. and type of contacts , '¢ www.altechcorp.com DATA SUBJECT TO CHANGE WITHOUT NOTICE RM84 / RM85 / RM87 Miniature Electromagnetic Relays Altech
Original
GZMB80 GZM80-0041 GZMB80-0040 MH16-2 RM87N
Abstract: protection is used to detect occurrence of earth-faults in not solidly earthed networks by detecting the , transformers connected between neutral and earth. The start function of the protection can be used to enable , protection RAEDA. The one consists of a test switch RTXP 8, for simple secondary testing, and a , of operate voltage, time delay and for choose of contact configuration, two electromechanical output relays, each with one change-over contact, and a red LED for indicating time function operation. When -
Original
079-BA 421-AA 002-AB rxeda Relay RHGX 60255-21-1 002AB RXME ABB 044-BEN SE970888 SE970871 079-AA
Abstract: + lockable front test button) - standard features of relays for plug-in sockets. Relays may be , for electromagnetic relays R2.WT, R3.WT, R4.WT with sockets GZT2, GZT3, GZT4 ELECTROPRODUCT 2003 for electromagnetic relays R2, R3, R4 Export Sales Department phone +48 68 47 90 838 · , (mechanical indicator + lockable front test button), for plug-in sockets. In standard version of relays (WT , · with mounting flange in the upper wall of the cover (without WT). Relays R2 are designed for: · Relpol
Original
R2-2012-23-1024-WT C250 R4P-0001-A R4P-0001-D R4W-0003-A R4W-0003-D R2-2012-25-1024
Abstract: R2, R3, R4 Industrial Electromagnetic Relays â'¢ â'¢ â'¢ â'¢ â'¢ â'¢ Compact size Relays , of relays for plug-in sockets. Relays may be provided with the test buttons (no latching) and plugs , of contacts Contact material Rated / max. switching voltage AC Min. switching voltage Rated load , Electromagnetic Relays R2 (DPDT) E105728 DIMENSIONS CONNECTION DIAGRAM LOAD CHARTS Fig. 2.1 Fig , '¢ www.altechcorp.com DATA SUBJECT TO CHANGE WITHOUT NOTICE 51 R2, R3, R4 Industrial Electromagnetic Relays Altech
Original
GZMB4-0040
Abstract: paths / lines of logic EASY600 · Integral password protection for circuit configuration and relay , Pollution degree Degree of protection (EN 50 178, IEC 60 529, VBG 4) Vibration resistance to IEC 60 , , severity level 3, ESD) Air discharge Contact discharge Electromagnetic fields (IEC/EN 61 000-4-3, RFI , Repetition accuracy of timing relays Accuracy of timing relays (of values) Resolution Range "s" Range "M , "Easy" Control Relays Technical Data Relay outputs Number in groups of Parallel connection of -
Original
EASY619-AC-RC moeller easy412-dc-rc EASY620-DC-TC moeller easy412-dc-rc Software EASY618-DC-RC EASY618-AC-RC HPL0211-2001/2002 EASY619/621
Abstract: Dimensions (W x H x D) Mounting Mounting position Material of enclosure Degree of protection Electrical , Measuring and monitoring relays CM-ESS.1 Voltage monitoring relays, single-phase AC/DC Data sheet , Adjustment of the measuring range DIP switches (see DIP switch functions) U/T: green LED control supply , Monitoring of DC and AC voltages from 3-600 V RMS measuring principle One device includes 4 measuring , adjustable from 3-30 % 3 supply voltage versions 1 c/o contact 22.5 mm width 3 LEDs for status indication ABB Automation
Original
R0300 R1300 R0100 Electronic scheme for AC adapter PA-6 AWG 2X12 CMESS cm-ess.1 F0205 F0206 F0003
Abstract: a range of instantaneous to a 30 s delay. 1 Measuring and monitoring relays CM-ESS.2 Voltage , H x D) Mounting Mounting position Material of enclosure Degree of protection Electrical , Measuring and monitoring relays CM-ESS.2 Voltage monitoring relays, single-phase AC/DC 2CDC 251 , adjustment Adjustment of the measuring range DIP switches (see DIP switch functions) U/T: green LED , Adjustment of the tripping delay TV Characteristics Monitoring of DC and AC voltages from 3-600 V RMS ABB Automation
Original
R0400 abb CM-ESS fuse abb mtbf IEC 60255-5 EN 1418 DIAGRAM LED TV R1400 F0005 D0201
Abstract: -1PS Electromagnetic Relay (RM699BV) contact information Number and type of contacts (code of output) Contact , -1246 Movable ejector: protection and easy replacement of the operational relay. All accessories are sold , -1PS Subminiature Electromagnetic and Solid State Modules Electromagnetic Relays Featuring Electromagnetic relay , important on ordering operational relays for sockets). For versions of the input voltage Un = 230 V AC/DC , important when ordering operational relays for sockets). For versions of the input voltage Un = 230 V AC/DC Altech
Original
RSR30 E228916 WB-1PS-36VDC-O PIR6WB-1PS-48VDC-O PIR6WB-1PS-60VDC-O PIR6WB-1PS-24VAC/DC-O
Abstract: Table of Contents Contents The Clare Advantage Page 4-5 Electromagnetic Relays CLAREification Chart (Electromagnetic Relays) DIP-14 (14 Pin Dual-In-Line Packages) MSS2, MSS7,PRMA, DSS7, PRME , , PD, PM Series Solid State Current Sensors - LDA Series OptoFILMTM Solid State Relays - OF Series , Contact Protection 48-51 52-53 54 55 Surge Arresters CLAREvoyance Chart (Surge Arresters) Surge , 1X0.1 Inch Grid Relays HRB, MMRB, MRB Staggered Pin Packages CUP 6, CUP 5, CUP 1 Special Application -
OCR Scan
clare relay cup CLARE REED RELAY PRMA solid state switches REED RELAY clare hgsm REED RELAY clare cUP hgsm DIP-16 DIP-10 MX100 MX200 MIT-101 MIT-115
Abstract: leading position of the manufacturer of electromagnetic relays in Europe provides for Relpolâ'™s , relay. Applications: there are two major applications of electromagnetic relays in solar systems , relays of the 2 NO contact configuration (each contact disconnects one line - one the phase line and , GZMB80 . 222 PIR6WB-1PS-.-R . 250 Electromagnetic relays In currents of contacts: 6 . , Monitoring relays â'" page 12 Innovative features of our tech­ ological n solutions and reliability of Relpol
Original
Abstract: Material of enclosure Degree of protection Electrical connection Wire size n/c contact n/o contact , circuits Kind of output Operating principle 1) Contact material Rated voltage (VDE 0110, IEC 947-1 , Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC Data sheet 2CDC 251 244 F0t05 Characteristics CM-SRS.11: 3 mA - 1 A CM-SRS.12: 0.3-15 A Monitoring of DC , versions 1 c/o contact 22.5 mm width 3 LEDs for status indication CM-SRS.1 Threshold value ABB Automation
Original
R0200 R1200 AC12
Abstract: Data sheet Thermistor motor protection relays CM-MSS.12 and CM-MSS.13 The thermistor motor protection relays CM-MSS.12 and CM-MSS.13 monitor the winding temperature of motors and protect them from , relays CM-MSS.12 and CM-MSS.13 | Data sheet Functions Operating controls 1 Indication of , . Operating mode The thermistor motor protection relays CM-MSS.12 and CM-MSS.13 are used to monitor the , sheet | Thermistor motor protection relays CM-MSS.12 and CM-MSS.13 - 3 Electrical connection T1 ABB
Original
IEC 60947-8 f0214 V0014 1SVR740700R0100 1SVR730700R0100 1SVR740700R2100
Abstract: Degree of protection (IEC/EN 60529) Vibrations (IEC/EN 60068-2-6) Constant amplitude 0.15 mm Constant , ) Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD) Air discharge Contact discharge Electromagnetic , g1 ms s min ­ ­ ­ 10 1 1 ­ 1000000 (10F) Repetition accuracy of timing relays Accuracy of timing relays (of values) Resolution Range "S" Range "M:S" Range "H:M" Retentive memory , Degree of protection (IEC/EN 60529) Vibrations (IEC/EN 60068-2-6) Constant amplitude 0.15 mm Constant -
Original
AWB2528-1423GB AWB2528-1508-GB AWB2528-1508GB EASY820-DC-RC EASY819-AC-RC EASY819-AC-RC moeller HPL0211-2004/2005 EASY200-EASY EASY202-RE EASY512- ZB4-101-GF1
Abstract: . Use of parts such as switches and relays that conform to EN and other standards. (2) Safety , interval using a control system. 2. Monitors contact welding using safety relays. Safety limit switch , found. (K3) 1. Contact welding: Detects whether the contacts of interface , whether the contacts of interface relays K1 and K2 as well as magnet contactors KM1 and KM2 are welded , for testing and certification of locking systems with electro-magnetic locking unit for safety OMRON
Original
jis c 8201-5-1 782Y IEC61310-1 IEC60947-1 EN50205 ISO12100-2 IEC60947-5-1 EN60947-5-1 AC-15 DC-13 EN50047 A000140
Abstract: R15 Industrial Electromagnetic Relays â'¢ â'¢ â'¢ â'¢ Contacts AgNi For plug-in sockets , (mechanical indicator and lockable front test button) - standard features of R15 DPDT, R15 3DPT relays in , type of contacts Contact material Rated / max. switching voltage AC Min. switching voltage Rated , Industrial Electromagnetic Relays DPDT CONNECTION DIAGRAM DIMENSIONS 22 (5) 12 (4) 24 (6) 35 , '¢ www.altechcorp.com DATA SUBJECT TO CHANGE WITHOUT NOTICE 67 R15 Industrial Electromagnetic Relays R15 Altech
Original
GZ14ZU GZ14U
Abstract: Electromagnetic Relays .50-71 Miniature Electromagnetic , .84-89 Subminiature Electromagnetic and Solid State Relays .90-101 Relays for , relays for emergency stop, safety gate and two-hand stop â'¢ CCA Component Carrier consists of a , ), reverse DC polarity protection, etc. Use bussed diodes for distribution of logic Vcc or ground, or gather , soldering of components. Posts or through-leads can be installed for future field connections. Contact Altech
Original
410-112013-5M TS35/
Abstract: number 85102208 Possibility of 110 VAC and 230 VAC power supply of 24 VDC safety relays   Output : secondary voltage 24 VDC / 200 mA High efficiency (80 %) Protection , Specifications Operating characteristics Functions Failure detection Display of output state by LED Universal Power supply for 24 VDC Safety Relays Short circuit and overload protection Power supply : U ,   50 / 60 Output specification Type Max. thermal current I for each contact Crouzet
Original
VAC/DC24 UL94VO 2002/95/CE
Abstract: category 0. Delayed contact expansion modules meet the requirements of Stop category 1. Safety relays , 04/064 Page 04/004 DILER mini contactor relays Basic units Auxiliary contact modules 04/010 04/010 04/010 DILR contactor relays Basic units Auxiliary contact modules Complete units , monitoring For protective door monitoring For contact/safety mat monitoring For monitoring of two-hand , Electronic Timing Relays Notes Terminal markings to EN 50 042 Std. Potential-free contact Do not -
Original
TPD11DIL ESR3-NO-31 ESR4-NZ-21 EMR4-F500-2 EMR4-W500-2-C EMR4-W500-2-D esr4-no-31 EMR4-W580-2-D DILET11 DILET70 ETR4-51 ETR4-69 ETR4-70 11DIL
Showing first 20 results.