500 MILLION PARTS FROM 12000 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

"Contact Protection of Electromagnetic Relays"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: electromechanical relays) and at the range of the rated contact load they offer highly reliable switching , protection While using electromagnetic relays in electric circuits, it should be borne in mind that coils , overvoltage protection modules of M series may be used with the relays and then the modules are mounted in , "-". Ordering codes of the overvoltage protection elements integrated in the relays (as add-on , relays successfully. The only theoretical limitations are the dimensions of relays, electromagnetic ... Relpol
Original
datasheet

21 pages,
856.08 Kb

RELAY feme a 100 RSM850B RSM850 RMB631 RM87 RM85 RM84 feme relay reed Overvoltage Protection Element Electric Welding Machine diagram feme relay 001 26 10 feme reed relays RELAY feme reed Feme Relays 001 feme relay Feme Relays TEXT
datasheet frame
Abstract: motors. The DCR100 DCR100 can also be used to switch AC circuits using external relays. An added benefit of , (Over Temperature Protection) • Relays Switchable Using Maretron DSM150 DSM150, DSM250 DSM250, N2KView®, or , Classification Degree of Protection Operating Temperature Environmental Comment 3.50” x 4.20” x , DCR100 DCR100 Direct Current Relays Maretron’s DCR100 DCR100 contains 6 Direct Current (DC) relays, each capable of switching up to 10 amps. The DCR100 DCR100 connects directly to an NMEA 2000® network, so ... Maretron
Original
datasheet

2 pages,
1043.26 Kb

DCR100 TEXT
datasheet frame
Abstract: RM84 / RM85 / RM87 Miniature Electromagnetic Relays • Miniature dimensions • Cadmium - free , versions with the increased dielectric strength of the contact clearance • IP67 flux proof, water proof and sealed cover protection (For IP40 unsealed, contact Altech) E105728 E105728 RM84 RM85 RM87 , PN-EN 116000-3 30 g 10 g 10.150 Hz max. 270 °C max. 5 s Contact Data No. and type of contacts , €¢ www.altechcorp.com DATA SUBJECT TO CHANGE WITHOUT NOTICE RM84 / RM85 / RM87 Miniature Electromagnetic Relays ... Altech
Original
datasheet

8 pages,
1814.49 Kb

TEXT
datasheet frame
Abstract: protection is used to detect occurrence of earth-faults in not solidly earthed networks by detecting the , transformers connected between neutral and earth. The start function of the protection can be used to enable , protection RAEDA. The one consists of a test switch RTXP 8, for simple secondary testing, and a , of operate voltage, time delay and for choose of contact configuration, two electromechanical output relays, each with one change-over contact, and a red LED for indicating time function operation. When ... Original
datasheet

8 pages,
66.58 Kb

079-BA 1mrk 002 4 change over relays 002-AB ac overvoltage protection datasheet IEC 61000-4-3 level pl 509 1MRK001 RXME ABB 002AB 421-AA 60255-21-1 RHGX 044-BEN rxeda Relay 044-BEN 044-BEN 044-BEN TEXT
datasheet frame
Abstract: + lockable front test button) - standard features of relays for plug-in sockets. Relays may be , for electromagnetic relays R2.WT, R3.WT, R4.WT with sockets GZT2, GZT3, GZT4 ELECTROPRODUCT 2003 for electromagnetic relays R2, R3, R4 Export Sales Department phone +48 68 47 90 838 · , (mechanical indicator + lockable front test button), for plug-in sockets. In standard version of relays (WT , · with mounting flange in the upper wall of the cover (without WT). Relays R2 are designed for: · ... Relpol
Original
datasheet

5 pages,
590.52 Kb

C250 R2-2012-23-1024-WT TEXT
datasheet frame
Abstract: R2, R3, R4 Industrial Electromagnetic Relays • • • • • • Compact size Relays , of relays for plug-in sockets. Relays may be provided with the test buttons (no latching) and plugs , of contacts Contact material Rated / max. switching voltage AC Min. switching voltage Rated load , Electromagnetic Relays R2 (DPDT) E105728 E105728 DIMENSIONS CONNECTION DIAGRAM LOAD CHARTS Fig. 2.1 Fig , €¢ www.altechcorp.com DATA SUBJECT TO CHANGE WITHOUT NOTICE 51 R2, R3, R4 Industrial Electromagnetic Relays ... Altech
Original
datasheet

8 pages,
2631.65 Kb

TEXT
datasheet frame
Abstract: paths / lines of logic EASY600 EASY600 · Integral password protection for circuit configuration and relay , Pollution degree Degree of protection (EN 50 178, IEC 60 529, VBG 4) Vibration resistance to IEC 60 , , severity level 3, ESD) Air discharge Contact discharge Electromagnetic fields (IEC/EN 61 000-4-3, RFI , Repetition accuracy of timing relays Accuracy of timing relays (of values) Resolution Range "s" Range "M , "Easy" Control Relays Technical Data Relay outputs Number in groups of Parallel connection of ... Original
datasheet

16 pages,
450.99 Kb

EASY412-DA-RC EASY412-AC-RCX EASY400-POW EASY618-AC-RE EASY619-DC-RC "easy-pc-cab" EASY412-DC-TC EASY412-AC-RC 412-AC-R EASY412-DC-RC EASY618-AC-RE moeller EASY620-DC-TE EASY204-DP HPL0211-2001/2002 PC easy-pc-cab HPL0211-2001/2002 EASY618-AC-RC HPL0211-2001/2002 EASY618-DC-RC HPL0211-2001/2002 moeller easy412-dc-rc Software HPL0211-2001/2002 EASY620-DC-TC HPL0211-2001/2002 moeller easy412-dc-rc HPL0211-2001/2002 EASY619-AC-RC HPL0211-2001/2002 HPL0211-2001/2002 HPL0211-2001/2002 TEXT
datasheet frame
Abstract: Dimensions (W x H x D) Mounting Mounting position Material of enclosure Degree of protection Electrical , Measuring and monitoring relays CM-ESS.1 Voltage monitoring relays, single-phase AC/DC Data sheet , Adjustment of the measuring range DIP switches (see DIP switch functions) U/T: green LED control supply , Monitoring of DC and AC voltages from 3-600 V RMS measuring principle One device includes 4 measuring , adjustable from 3-30 % 3 supply voltage versions 1 c/o contact 22.5 mm width 3 LEDs for status indication ... ABB Automation
Original
datasheet

6 pages,
389.71 Kb

R1300 60255-21-1 mtbf abb CM-ESS AC12 BC 148 L bc 660 01X10-6 Federal fuse switch fuse abb mtbf heidelberg circuit R0100 R0300 cm-ess.1 CMESS AWG 2X12 Electronic scheme for AC adapter PA-6 TEXT
datasheet frame
Abstract: a range of instantaneous to a 30 s delay. 1 Measuring and monitoring relays CM-ESS.2 Voltage , H x D) Mounting Mounting position Material of enclosure Degree of protection Electrical , Measuring and monitoring relays CM-ESS.2 Voltage monitoring relays, single-phase AC/DC 2CDC 251 , adjustment Adjustment of the measuring range DIP switches (see DIP switch functions) U/T: green LED , Adjustment of the tripping delay TV Characteristics Monitoring of DC and AC voltages from 3-600 V RMS ... ABB Automation
Original
datasheet

6 pages,
402.56 Kb

R0100 ABB STOTZ-KONTAKT S 211 fuse code c AC12 DIAGRAM LED TV EN 1418 R0400 IEC 60255-5 fuse abb mtbf CMESS abb CM-ESS TEXT
datasheet frame
Abstract: -1PS Electromagnetic Relay (RM699BV RM699BV) contact information Number and type of contacts (code of output) Contact , -1246 Movable ejector: protection and easy replacement of the operational relay. All accessories are sold , -1PS Subminiature Electromagnetic and Solid State Modules Electromagnetic Relays Featuring Electromagnetic relay , important on ordering operational relays for sockets). For versions of the input voltage Un = 230 V AC/DC , important when ordering operational relays for sockets). For versions of the input voltage Un = 230 V AC/DC ... Altech
Original
datasheet

4 pages,
475.3 Kb

TEXT
datasheet frame