Part Manufacturer Description PDF & SAMPLES
AFM-01NC Orion Fans AIR FLOW SWITCH NC
AFM-01NO Orion Fans AIR FLOW SWITCH NO
AFM-92NO Orion Fans AIR FLOW SWITCH W/92MM GUARD NO
AFM-80NC Orion Fans AIR FLOW SWITCH W/80MM GUARD NC
AFM-80NO Orion Fans AIR FLOW SWITCH W/80MM GUARD NO
AFM-120NC Orion Fans AIR FLOW SWITCH W/120MM GUARD NC

"Air Flow switch"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: air] 4. Make sure to use a switch within the specified flow rate for measurement and the maximum , . [For air] 2. Fluids for measurement for this digital flow switch are nitrogen and air. Please note , international standards, visit us at www.smcworld.com. Digital Flow Switch For Air Series PF2A How to , . HR24 DDK Ltd. CM01-8DP4S Digital Flow Switch For Air PF2A Series Dimensions , Connector pin numbers 4 FLOW SWITCH 34 54 44 UP SET OUT1 OUT2 DOWN 1 FOR AIR SMC
Original
IFW510 IFW520 IFW550 PF2A PF2A751 1F33 PF2A710 PF2A721 PF2A711 PF2A510 PF2A521 PF2A511
Abstract: pressure 30 kPa (ISA2-G). Digital Flow Switch Series PF2A/PF2W · Either for air or water. · Simple , service life. Digital flow switch for air or water, integrated display type Fluid Dry air, N2 , ~ 40 10 ~ 100 0,1 0,5 1,0 NPN on request Digital flow switch for air or water, remote type , sensors SMC Pressure &Flow sensors ZSE/ISE Series -Pressure Switch PSE Series -Pressure Sensors PF2 , and Switches for general Air Integrated Display Type Flow rate: 10 to 12.006 l/min · Flow rate SMC
Original
ISE70-F02-65 ZSE40F-01-22L ISE40-01-62 str 12006 ZSE30-01-65-L ISE40-01-22L 325MP PSE540 PSE530 PSE550 PSE200 PSE300
Abstract: PF2A Series Digital Flow Switch for Air Digital Flow Switch For Air Series PF2A Features Flow switch for air. Thermal detection has no moving parts and very little resistance to airflow , _3, 4 and P_1, 2 to be P_3, 4.) Page 1440 Digital Flow Switch for Air Series PF2A , for Air Digital Flow Switch For Air Series PF2A Features Flow switch for air Thermal , 1442 1/2 Digital Flow Switch for Air Series PF2A Dimensions: Remote Type Sensor Unit for -
Original
PF2W740 PF2W720 PF2W704 PF2A706H PF2W540 PF2A712H PF2A750 PF2A721/PF2A751 PF2W504T PF2W504T/520T/540T- PF2W504T--1 PF2W520T--1
Abstract: -PP003 HVAC Temperature Transmitters 1414-PP004 Air Flow Transmitter 1414-IN001 Current Switch 1414-IN002 Air Flow Switch 1414-IN003 Duct Average Temperature Transmitter 1414 , -IFZ35FGDAA Air Flow Transmitter Allen-Bradley DP 1 1414-CPN10APWAB Differential Pressure Switch , (4 - 20 ma) B (Switch) P - (Process) F - (Air Flow) D - (Display) 10 - (1.0%) F - , -CPN10APWAB Differential Air Flow Switch (± 0.02 in wc to 12 in wc) auto reset 1414-CPN10APQAB Differential Air Flow Rockwell Automation
Original
1414-CTZ03PBRAA 1414-ITZ02GBRAA 1414-CTX03PDDAA 1414-CHZ30PKRAA pcb split hvac 1414-CHD30PKRAA 1414-SG001A-EN-P
Abstract: °C Lubrication_Not advised Max. suction flow rate/air consumption unit (Nl/min) Specifications Max. suction flow , ) 232-3721 Exhaust characteristics/flow characteristics Flow characteristics: at 4.5kgf/cm supply air , Suction flow rate Nl /min Air consumption Nl /min pr es Applicable tube Note 2) Va c ­ 400 ­ , 0 0 1 2 3 4 5 6 Supply air pressure kgf/cm2 0 2 4 6 8 10 Suction flow rate Nl , 300 Va c Ai r n co su 20 Suction flow rate Nl /min Air consumption Nl /min m RS Components
Original
flow control valve accuracy Air suction silencer
Abstract: "Probe Retracted" 10 Mechanical end switch 11 Plunger compressed air connection 12 Connection of , air from an air shock blower will not flow outward. 42/23-54 EN Rev. 2 ACK Advance Cement Kiln , Install the heat exchanger close to the analyzer cabinet. Air Flow Leave approx. 1 m of space in front of and behind the heat exchanger to allow unobstructed supply and discharge flow of cooling air , approx. 20 s. Pressure Switch Setting Set "Compressed Air Present" pressure switch "-S30" to ABB Automation
Original
bottle filling circuit diagram AO2000 Uras14 Limas11 wiring diagram for water pump AEROSOL FLAMMABLE CORROSIVE
Abstract: · Air supply valve for generating a vacuum · Vacuum release valve (equipped with a flow ZY ZH , equipment Functions Vacuum picking and transport, vacuum picking and securing, and vacuum air flow , ZM07H ZM10H ZM13H ZM07M ZM10M ZM13M Standard supply pressure H M Max. suction flow Air , . When the supply valve is turned OFF, the atmospheric pressure causes the air to flow back from the , at maximum value (Pmax). 2) When suction port is opened gradually, air can flow through, (air -
Original
dxt170-75-1 VJ114 VJ10-20-4A-10 ZM131h-k5lz-e15 VJ324M ZM132H
Abstract: air] 4. Make sure to use a switch within the specified flow rate for measurement and the maximum , . [For air] 2. Fluids for measurement for this digital flow switch are nitrogen and air. Please note , Switch Series PF2A/PF2W For Air For Water Flow rate setting and monitoring are possible with , international standards, visit us at www.smcworld.com. Digital Flow Switch For Air Series PF2A How to , sensor unitis comformed to CE mark. 16-11-8 1/2 Digital Flow Switch For Air Series PF2A SMC
Original
3-digit object counter circuit Yamatake 3000 flow elements 1.61.118 PF2A706H-28 PF2W300 PF2A703H-69 D-107
Abstract: measuring Micro Flow Switch â'¢ monitoring with Factory Set Switch Point â'¢ analyzing KSR / SVN â'¢â'¢ Flow Switch for Low Volumes of Water or Air â'¢â'¢ Reed Contact or Proximity Switch â'¢â'¢ Vertical Connections for In-line Mounting â'¢â'¢ Switching Ranges: 0.03.4.0 GPH , 1.412.788.4890 info@koboldusa.com www.koboldusa.com Micro Flow Switch with Factory Set Switch Point Models , , KOBOLD can supply an appropriate isolation relay to protect the flow switch contacts from overload KOBOLD Instruments
Original
SVN-1200 KSR-1200 KSR-1201 SVN-1201
Abstract: / pre-heating temperature) "AIR" Control Key (air flow rate) "TEMP" Control Key (hot air temperature) LED , temperature at the hand-piece can be adjusted over the range of 50°C 550°C (150°F 999°F). The air flow , . Hot air temperature and air flow rate are digitally controlled. The vacuum necessary for lifting , work at the hot air temperature and air flow rate set. Hot air and vacuum can be activated using the , temperature, air flow rate, temperature of the optional WHP3000 PreHeat Plate and vacuum function can be Weller
Original
3000P RS232 WHA3000P NQT10 NQT25 WHA3000P/V
Abstract: load voltage [For air] 6. Use the switch within the specified flow rate measurement and operating , switches for air. Detection principle of digital flow switch for air Detection principle of digital , For Water Digital Flow Switch Series PFW How to Order Integrated Display Type PFW7 20 , digital flow switch with unit switching function. (Fixed SI unit [l/min or l] will be set for switch type , is 1digit. (refer to the table above). 20 For Water Digital Flow Switch Series PFW -
Original
PFW720 PFW740 PFW301 PFW7T-67 PFW321 smc fitting PFW704 PFW711
Abstract: Flow adjustment valve Air filter Regulator Micro mist separator Flow switch IDFA , Flow Switch Variations For Air Integrated type Remote type Model Measurement flow range , 2-Colour Display Digital Flow Switch Flow rate range: 10, 25, 50,100 l/min. Minimum unit setting: 0.01 l/min. Fluid (0.1 l/min when the flow rate range is 25, 50, 100 l/min.) Air, N2, Ar, CO2 , mount compatible Series PFM CAT.EUS100-63B-UK 2-Colour Display Digital Flow Switch Integrated SMC
Original
PFM711 PFM725 PFM710 PFM750 Silicon Fluid MS 550 PFM511 LV-1006 SK-81107 SF-02231 LT-04123 SLO-8210
Abstract: Miniature Flow Monitor SW112 for air and inert gases Description The Miniature Flow Monitor SW112 , pipe diameter LED status indication Relay output for flow Fast response time Suitable for air and , function flow rate 1 switch point (MIN) Display flow rate 1 LED (green) Temperature range , conductivity. (2) Delay with the switch point set to 5 m/s and the flow at 10 m/s, after a sudden complete stop. 05/06 www.e-t-a.com 135 Miniature Flow Monitor SW112 for air and inert gases E-T-A
Original
0Z122Z000131 miniature mass air flow sensor air flow Monitoring sw112 SW112-re miniature air mass sensor AC/DC24 SW112-RE 0Z122Z000128
Abstract: . Suction flows up to 200 l/min. Optional integrated pressure gauge or digital vacuum switch. Supply air , (ANR) 100 l /min (ANR) 63 l /min (ANR) Maximum suction flow rate Air consumption Maximum , Charts ZL212 150 125 ­80 ­70 e rate flow t on Sucti on mpti onsu Air c ­60 ­50 , AVAILABLE Vacuum 0 ­100 ­90 Suction flow rate (l/min (ANR) Air consumption (l/min (ANR , ­90 Suction flow rate (l/min (ANR) Air consumption (l/min (ANR) Exhaust Characteristics -
Original
ZL112 Digital Pressure Gauge circuit diagram vacuum pressure switch ZL112-K1L-E25 SYJ514- how to read ZSE4-00-X105 E813-B
Abstract: for each branch line Features 2 For Air Digital Flow Switch Series PF2A Refer to , conforms to the CE mark. 1 For Air Digital Flow Switch Series PF2A How to Order Remote , conforms to the CE mark. 3 For Air Digital Flow Switch Series PF2A How to Order 4 , Stainless steel PBT PBT 100 For Air Digital Flow Switch Series PF2A Dimensions: Integrated , FLOW SWITCH DC(­) 4 OUT2 DOWN FOR AIR 2-Port size 30 4 ­ ø4.5 40 50 6 SMC
Original
PF2A31 PF2A551 PF2A20 PF2A200 PF2W711 Nitrogen Relief Valve ES100-54 PF2200 SF-02031 LT-2600 SLO-8360
Abstract: ) Specify the FS-3 Flow Switch using part numbers tabulated below. Set points other than those listed are , with special configurations, including Gas (Air) flow, and customer specified electrical terminations , FLOW SWITCHES FS-3 Series ­ Compact, Low Flow Units for Clean Potable Water Applications Flow , Spring and Stop Pin Pressure Rating Operating Temperature Required Filtration Switch* Electrical , compliant. * See "Electrical Data" on Page X-5 for more information. N.O. switches in No Flow condition Gems Sensors
Original
E31926 165840-A 165841-A 165842-A 165843-A
Abstract: of the Air Pressure and Vacuum cTemperature Set-Back cSeparate Control of Air Flow 984-2853. KDS808 , Flow Can Be Easily Activated by Finger Switch cVacuum Pick-Up Pen for Component Handling cPrecision , to Prevent Dripping air flow are controlled on a highly visible front panel and, with an extremely c , Light (LED) compact size, this powerful hot air station uses less space on the bench. Air flow c comes , 0-100 PSI Regulators and Gauges with Locking Ring cSeparate Control of Air Flow cBenchtop Unit for Easy Allied Electronics Catalog
Original
WHA300 CQFP24 EC1204 smd led 5060 SMD 5060 LED WRS3000 WRS5000 KDS808D F-1022 PLCC84 PLCC18/22
Abstract: resistance to air flow from the end of the pipe placed inside, near the bottom of the tank. As the liquid , Daykin Liquid Level Detector operates by bleeding a constant flow of compressed air through the end of an , 1.0 S.C.F.H. E PLANT AIR PRESSURE - Adjust bellows of switch to close N.O. contact at 20 RS.I. A , 1.0 S.C.F.H. air flow rate at 20 RS.I. - Slight deviations can result in improper readings and control , possible to simulate the required readings on the dial by restricting the air flow in sensing line between -
OCR Scan
AIR FLOW DETECTOR circuit LEVEL DETECTOR level gauge for tank C4-0496
Abstract: safety functions by controlling gas flow, ignition source, and a 120 Vac or 240 Vac combustion air , the ignition system control switch. 2. Mount so the gas flow is in the direction of the arrow on , AIR SV9440 SV9540 SV9640 HEAT 3 6 AIR PROVING SWITCH LIMIT SWITCH L1 XFMR CONT COOL NEUTRALS AUXILIARY LIMIT SWITCH (OPTIONAL) ROLLOUT SWITCH ELECTRONIC AIR , TRANSFORMER L1 L2 PRESSURE SWITCH LIMIT SWITCH AIR INDUCER BLOWER MOTOR COMMON LOAD -
Original
SV9541 SV9641 Q3450 ST9160 ST9162 air blower ST-9160 Q3480
Abstract: provides a sensitive and fast response to the flow of air or other gas over the chip. Dual sensing elements , cavity air space beneath the flow sensor bridges. The small size and thermal isolation of the microbridge , â'¢ Bidirectional sensing capability â'¢ Actual mass air flow sensing The AWM2000 series , temperature and air flow. Ambient temperature is sensed by a similar heatsunk resistor on the chip. This mode , the air stream flow past the chip parallel to its surface. In addition, the microstructure is kept -
OCR Scan
AWM5000 AWM5104VN SS12143 Wheatstone Bridge amplifier massflow interface AWM3100V airflow sensors AWM2100V AWM5104V AWM5101VA AWM5101VC AWM5101VN AWM5102VA