Part Manufacturer Description PDF & SAMPLES
SN65LVDS047DR Texas Instruments Quad LVDS Transmitter with Flow-Through Pinout 16-SOIC -40 to 85
SN65LVDS048AD Texas Instruments Quad LVDS Receiver with Flow-Through Pinout 16-SOIC -40 to 85
MSP430FW425IPMR Texas Instruments 16-bit Ultra-Low-Power Microcontroller for Electronic Flow Meters 64-LQFP -40 to 85
SN65LVDS047PWRG4 Texas Instruments Quad LVDS Transmitter with Flow-Through Pinout 16-TSSOP -40 to 85
SN65LVDS048APWG4 Texas Instruments Quad LVDS Receiver with Flow-Through Pinout 16-TSSOP -40 to 85
TDC1000PW Texas Instruments Ultrasonic Sensing Analog Front End for Level, Concentration & Flow Sensing 28-TSSOP -40 to 125

"Air Flow Sensor"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: No. V 9GV3612J301 9GV3612G301 Without Sensor 12 Rated Speed Air Flow V A W , to 13.2 4.5 to 13.2 Pulse Sensor Available in all models. Rated Speed Air Flow Static , Network . P.277 to 278 2 DC San Ace Domain Diagram DC Fan Air Flow(m3/min , 300 350 500 1000 1500 7.0 8.0 9.0 Silent Fan Frame Size Air Flow(m3/min) 0.1 0.2 60mm sq. 80mm sq. 92mm sq. 120mm sq. Air Flow(CFM) 0.3 0.4 0.5 0.6 0.7 SANYO DENKI
Original
San "Ace 92" 109p0424h7 SDT 1000 thermistor 109p0424 109P0424H601 H-1161 F-95958
Abstract: riseK=15K T V Heat source Q' 2. Calculating the Motion Air flow Required for Cooling After the equipment specifications and conditions have been determined, calculate motion air flow required , performed only by cooling air from the fan motor.) Example Q': Motion air flow (m3/min.) V 100W Q'= = 0.33m3/min 20T 20×15K 3. Selecting the Fan Motor Selecting the Fan Motor After the motion air flow has been calculated, select an appropriate fan motor based on the value. The motion air flow when the fan SANYO DENKI
Original
heat sensor with fan cooling circuit heat sensor with fan cooling Sanyo Denki dc fan Vibration Sensor fan San Ace 120L motor dc fan 12v
Abstract: Air Flow 9GA0612P6G001 Operating Voltage Range With PWM speed control functionWith pulse sensor , . P.321 to 322 2 DC San Ace Domain Diagram Low Power Consumption Fan Air Flow(m3/min , . Air Flow(CFM) Conversion table 1m3/min=35.31(CFM) 1CFM=0.0283m3/min /sec 1m3/min=16.67 1CFM=0.472 , 200 250 300 Silent Fan Air Flow(m3/min) Frame Size 0.1 0.2 0.3 0.4 0.5 0.6 , . 92mm sq. 120mm sq. Air Flow(CFM) Conversion table 1m3/min=35.31(CFM) 1CFM=0.0283m /min 3 P SANYO DENKI
Original
San Ace 40 DC brushless centrifugal blower 12v brushless motor fan cpu 9GA0412P3J01 9GA0512P7G001 San Ace 60 9GA0512P7A001 C1007B001
Abstract: 119±0.5 104.8±0.5 Mounting Hole 8-3.7 Rotating Direction Air Flow Direction with Sensor , and that for sensor pull-up are separated. 115 AIR FLOW 104.8±0.3 104.8±0.3 AC Fan , Flow 40 Air Flow Air Flow 40 109S085 109S084 109S088 109S087 with Sensor inch , Sensor rated voltage,and continuously run in a free air state) Dielectric Strength . 50/60Hz , Locked Rotor Current Rated Speed A min-1 m³/min Air Flow CFM Pa Static Pressure -
Original
109S485 109S484 109S488 San Ace 120 109-019K AWG28 UL1007 UL94V-1 50/60H 500VAC 000VAC 109S081 109S083
Abstract: No. V 9GV3612J301 9GV3612G301 Without Sensor 12 Rated Speed Air Flow V A W , to 13.2 4.5 to 13.2 Pulse Sensor Available in all models. Rated Speed Air Flow Static , ) 9GV0412J301(3011) 9GV0412G301(3011) Without Sensor V Air Flow 7 13.2 Pulse Sensor Available in , while achieved high large air flow and high static pressure. 40mm sq. 92mm sq. Cooling fan that can , Network . P.323 to 324 2 DC San Ace Domain Diagram DC Fan Air Flow(m3 SANYO DENKI
Original
109p0412 109p0424h San Ace 80 94v0 p-311
Abstract: AIR FLOW 11 Rotating Direction 6. 92±0.5 92±0.5 with Sensor 300L , . with Sensor 1.5 3-4 Air Flow Direction Rotating Direction 11 92±0.5 82.5±0.3 , Air Flow Direction Wiring diagram FAN 5V with Sensor FAN Sensor circuit , 172mm P.33 to 36 Air Flow(CFM) 5 10 15 20 25 30 35 50 100 , -1 Air Flow Static Pressure SPL m³/min CFM 0.07/0.06 0.06/0.05 2250/2700 0.27/0.33 SANYO DENKI
Original
109S005 H1161 109S405UL San Ace 172 109S075UL SMC Pneumatics S-187
Abstract: light weight air pressure Sensors Compact Pressure Sensor Air pressure sensor Low Differential , and Switches for general Air Integrated Display Type Flow rate: 10 to 12.006 l/min · Flow rate , water Digital Flow Sensors and Switches for general Water Sensor type Flow rate: 4 to 100 l/min , ) Display unit PF2W3 F4 4 channel PF2W20 Sensors & Switches Sensor Type Flow rate 10 to 500 l , monitored by a single controller. 2 4 4-channel Flow Monitor 3 Series PF2200 eral air For SMC
Original
ISE70-F02-65 ZSE40F-01-22L ISE40-01-62 str 12006 ZSE30-01-65-L ISE40-01-22L 325MP PSE540 PSE530 PSE550 PSE200 PSE300
Abstract: . When air flow is present, the side of the flow sensor facing the source of the airflow cools and the , FOR IMMEDIATE RELEASE OMRON Releases New Cyclone-type MEMS Flow Sensor Highly Dust Resistant, Ideal for Sensing Air Flow in HVAC Air Handling Equipment November 2007 - Schaumburg, IL - OMRON Electronic Components LLC has announced the release of a new MEMS flow sensor. Incorporating a unique cyclone-type Dust Segregation System (DSS), the new flow sensor is ideal for applications that require sensing OMRON
Original
Airflow Sensor Breathing mems Flow Sensor omron pressure sensor
Abstract: measurement positoin Air Velocity Sensor 48 dia. 20.8 60 D6F-W10A1 Flow Velocity (m/s) 0 2 , 25±5 °C. and dry air. Fig. 2. Honeycomb air flow laminater Air Velocity Sensor 155 dia. 18 , Clogged Filter Detection The D6F-W air flow sensor detects the decrease in air velocity through the , MEMS Air Velocity Sensor D6F-W MEMS precision technology for repeatable airflow velocity , Flow Range PPS Air (See note 1.) 0-1 m/sec D6F-W01A1 0-4 m/sec Cable Connector Assembly OMRON
Original
D6F-W04A1 velocity sensors air velocity sensors velocity sensor d6f-w10 MEMS humidity sensor 24VDC X305-E-1
Abstract: THERMAL SENSORS AFS Air Flow Sensor Units Thermal Sensors Construction AFS0001 40 , temperature compensation circuit assures correct values regardless of air temperature. The air velocity sensor and air velocity temperature compensation sensor are sensors with the same characteristics to enable , Air flow control of hot water boilers. Air flow control of air conditioning systems for buildings. Air flow control and stoppage detection of fan mortors. Air flow control of clean rooms and clean KOA Speer Electronics
Original
control circuit diagram humidity sensor CIRCUIT DIAGRAM FOR temperature sensor Humidity dew sensor temperature sensor diagram AFS0002
Abstract: / W04A1 Precision air flow detection sensor Flow Range 1m/s (D6F-W01A1) 4m/s (D6F-W04A1) Ultra , 1.00 0.0 Flow velocity(m/s) 1.0 D6F-V03A1 Precision air flow detection sensor Flow Range , particulates (simulation result). Gas/Air Flow Flow measurement principle Inside each D6F there is a , Air Flow Sensors Our family of MEMS Flow Sensors includes intelligent compact models capable of , Scientific Devices Gas flow controller Fans Mass Flow Sensors D6F-P Uni-directional mass flow sensor OMRON
Original
LPG GAS SENSOR AIR FLOW DETECTOR CIRCUIT DIAGRAM LPG GAS DETECTION AND CONTROL LPG GAS DETECTOR laparoscopic surgery OZONE GENERATOR S-164 Y910-E2-03
Abstract: 737 FIBER SENSORS Integrated Display Type Digital Flow Sensor FM-200 SERIES Related , Display Type Digital Flow Sensor FM-200 SERIES APPLICATIONS 738 FIBER SENSORS Controlling , When there is no flow For example, using a single sensor to check chip suction Suction When there is flow Vacuum breakdown Flow Temperature distribution Temperature sensor 1 Heater , New rectification mechanism One sensor detects both directions PRESSURE / FLOW SENSORS Panasonic
Original
sensor Flow meter PNP FM-252-4 FM-255-AR2
Abstract: 10.8±0.4 7.5±0.4 M4×0.7,5mm 0.75 deep Earth Ground tap AIR FLOW ROTATION with Sensor 10.8±0.4 7.5±0.4 M4 0.7,5mm M4× × 0.75 deep Earth Ground tap AIR FLOW ROTATION 172±0.8 172±0.8 162±0.5 , Round type Air Flow Static Pressure Pa inchH²O Specifications Standard Voltage V Frequency , Rated Speed A min-1 Air Flow m³/min CFM Static Pressure Pa inchH²O SPL dB(A , Flow Direction Rotating Direction Air Flow Direction 35 Reference dimension of Unit -
Original
air flow sensor UL1007 AWG28 109-312 109-372 air speed sensor UL1007 AWG18 109-319E 109-319H 489-1619-L10 E50197 LR67048
Abstract: shows how the sensor signal (VRL) is affected by air flow. The test procedure involves situating the sensor in an air stream of 3.1 meters per second, with the air flow vertical/horizontal to the , by the air flow. As a result, direct air flow on the sensor should be avoided. Figure 19 , current of Effect of air flow , as measured for more than 700 days. The sensor is first energized in normal air. Measurement for -
Original
TGS2620 figaro TGS 203 CO Detector TGS 800 figaro TGS 2600 SENSOR TGS 2600 figaro TGS methane gas sensor ISO9001
Abstract: caused by the air flow. As a result, direct air flow on the sensor should be avoided. 0.9 0.8 Rs , (V) Figure 20 shows how the sensor signal (VRL) is affected by air flow. The test procedure involves situating the sensor in an air stream of 3.1 meters per second, with the air flow vertical , .10 Ignition Effect of Air Flow , air. Measurement for confirming sensor characteristics is conducted under standard test conditions -
Original
TGS2610 TGS 800 gas sensor Figaro CO2 sensors TGS 2600 series figaro TGS gas sensor GAS SENSOR TGS 2600
Abstract: operated with a varying air flow for the ozone delivery system then the minimum flow over the sensor should be such that the power required to maintain the sensor at 500 °C, without air flow, is increased , power into the sensor heater while the sample air/gas flow is running. 6.2. Integrated Ozone Switch , the sensor. 3.2. Capteur recommend that the sample ozone/air mixture is driven passed the sensor , free of volatile organics and especially ozone. A facility to present the sensor with clean air at the Capteur Sensors
Original
ozone generator circuit Capteur Ozone Sensors ozone sensor GAS SENSOR for ozone ozone heat sensor fan project
Abstract: cavity air space beneath the flow sensor bridges. The small size and thermal isolation of the microbridge , flow through the inlet and outlet ports of the package. The microbridge mass airflow sensor has a , provides a sensitive and fast response to the flow of air or other gas over the chip. Dual sensing elements , sensors will not sense liquid flow, and may be damaged by high velocity liquid flowing through the sensor , â'¢ Bidirectional sensing capability â'¢ Actual mass air flow sensing The AWM2000 series -
OCR Scan
AWM5000 AWM5104VN SS12143 Wheatstone Bridge amplifier massflow interface AWM3100V airflow sensors AWM2100V AWM5104V AWM5101VA AWM5101VC AWM5101VN AWM5102VA
Abstract: D6F-W01A1 Connecting 3-wire cable for D6F clog sensor Air Velocity Sensor - D6F-V RoHS Unique Dust , . 70241619 Mfr.'s Type D6F-V03A1 Case Material PBT Applicable Gas Air Flow Range 0-3 m/Sec Supply Voltage , Flow Sensor with Dust Segregation System - D6F-P POWER Compact Easy-to-Use High Accuracy, Reliable , Flow Sensors - D6F Small Size Foot Response Applicable to Air, Non-Corrosive Gas, Natural Gas and , Applicable Gas Natural Gas Air, N2O, O2 Air, N2O, O2 Air, N2O, O2 Air Air Air Flow Range 0-5 LPM 0-10 LPM -
Original
flow sensor "piezo" propane gas NATURAL GAS SENSOR gas sensor o2 n2o sensor D6FW10A1 D6F-P0010A1 D6F-P0010A2 D6FP0001A1 D6FP0010AM2 D6F02A1110
Abstract: Temperature sensor (NTC-resistor) for controlling the motor speed is positioned directly in the air flow , S-Panther range are the right solution. A strong pressure saddle curve at optimum air flow 2014-11 , ACmaxx / GreenTech EC-Compact fans m3/h mm c Air flow Series Dimensions Overview of , 725.905 W1G 250 2070 *1G 300 2320.2345 Page Air flow Series Dimensions Overview of , centrifugal fans Housing: GRP1) (PBT) Impeller: GRP1) (PA) Direction of air flow: Exhaust over struts ebm-papst
Original
300-AC19 300-DC19 300-AC33 300-DC33
Abstract: some simple procedures. Sensor Preparation Air Initialization The air initialization procedure , Sensor Preparation NOTE: It is extremely important that a good air initialization is obtained before attempting to take liquid measurements. The air initialization must be done with an absolutely dry sensor , reduce baseline noise. Flow and noise are coupled because the Spreeta sensor is typically not at the , to produce pulse-free flow in the Spreeta sensor. Refractive index changes may be observed with any Texas Instruments
Original
spreeta ABSTRACT OF AIR FLOW DETECTOR spreeta LED water pumping machine control air flow detector abstract air flow detector sensor SLYA017A SLYA017
Showing first 20 results.