500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Direct from the Manufacturer

Part Manufacturer Description PDF & SAMPLES
CS2000CP-DZZ Cirrus Logic Phase Locked Loop, Hybrid, PDSO10, 3 MM, LEAD FREE, MO-187, MSOP-10
CS2100P-CZZ Cirrus Logic Phase Locked Loop, Hybrid, PDSO10, 3 MM, LEAD FREE, MO-187, MSOP-10
CS2200P-DZZ Cirrus Logic Phase Locked Loop, PDSO10, 3 MM, LEAD FREE, MO-187, MSOP-10
CS2300P-CZZ Cirrus Logic Phase Locked Loop, Hybrid, PDSO10, 3 MM, LEAD FREE, MO-187, MSOP-10
CS2000P-CZZ Cirrus Logic Phase Locked Loop, Hybrid, PDSO10, 3 MM, LEAD FREE, MO-187, MSOP-10
CS2100P-DZZ Cirrus Logic Phase Locked Loop, Hybrid, PDSO10, 3 MM, LEAD FREE, MO-187, MSOP-10

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : 3PHASELV-KIT Supplier : NXP Semiconductors Manufacturer : Avnet Stock : - Best Price : $225.00 Price Each : $225.00
Part : 3PHASELV-KIT Supplier : NXP Semiconductors Manufacturer : Avnet Stock : - Best Price : - Price Each : -
Part : KIT_AK_3PHASE_DRIVE_V1 Supplier : Infineon Technologies Manufacturer : Avnet Stock : - Best Price : - Price Each : -
Part : 3PHASELV-KIT Supplier : NXP Semiconductors Manufacturer : Newark element14 Stock : 5 Best Price : $225.00 Price Each : $225.00
Part : 3-PHASEMOTORDRIVEAPPKIT Supplier : Infineon Technologies Manufacturer : Rochester Electronics Stock : 1 Best Price : - Price Each : -
Part : 3PHASELV-KIT Supplier : Freescale Semiconductor Manufacturer : Rochester Electronics Stock : 1 Best Price : $281.25 Price Each : $346.1500
Part : KIT_AK_3PHASES_DRIVE_V1 Supplier : Infineon Technologies Manufacturer : Rochester Electronics Stock : 2 Best Price : - Price Each : -
Part : 3PHASELV-KIT Supplier : Freescale Semiconductor Manufacturer : Ameya Holding Stock : - Best Price : - Price Each : -
Part : 3PHASELV-KIT Supplier : NXP Semiconductors Manufacturer : element14 Asia-Pacific Stock : - Best Price : $285.5200 Price Each : $285.5200
Shipping cost not included. Currency conversions are estimated. 

"3 phase" Datasheet

Part Manufacturer Description PDF Type
3PHASEPWM International Rectifier 3-Phase Synchronous PWM Controller IC Provides an Integrated Solution for Intel VRM 9.0 Design Guidelines Original

"3 phase"

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: LXM 05pD10M3X 230 3-phase 0.43 6000 0.42 Servo motor characteristics Maximum mechanical , single phase With LXM 05pD10M3X servo drive 230 V 3-phase Torque in Nm 2,0 Torque in Nm 2,0 , LXM 05 pD10M3X 230 3-phase LXM 05 pD10M3X 230 3-phase 2.7 0.8 4000 5.9 LXM 05 pD14N4 400/480 3-phase 0.70 6000 Servo motor characteristics Maximum mechanical speed , drive 230 V 3-phase Torque in Nm 4 Torque in Nm 4 3 3 1 Mmax 2 2 1 M0 0 -
Original
bsh servo 0703P 1404M 0553P 0553T 103RP 0551T D10F1 D10M2 D10M3X 43742-EN
Abstract: : saleshelp@tripplite.com Model #: SUDC208V42P 20-60kVA 3 Phase Power Distribution Center Highlights Full size Rack Power Distribution Cabinet supports 20-60kVA 3 phase UPS power distribution in datacenter equipment racks 42 pole breaker panel supports 3 phase 208V and single phase 208V and 120V output to connected , Description Tripp Liteâ'™s SUDC208V42P Power Distribution Cabinet supports 20-60kVA 3 phase UPS power , circuit breaker panel supports 3 phase 208V and single phase 208V and 120V output via optional corded Tripp Lite
Original
SR42UB L21-20R SUWL2120C-40 SUWL2130C-5 L21-30R SUWL2130C-10
Abstract: 20-60kVA 3 Phase Power Distribution Center MODEL NUMBER: SUDC208V42P Highlights Full size Rack Power Distribution Cabinet supports 20-60kVA 3 phase UPS power distribution in datacenter equipment racks 42 pole breaker panel supports 3 phase 208V and single phase 208V and 120V output to connected , PDUs Description Tripp Liteâ'™s SUDC208V42P Power Distribution Cabinet supports 20-60kVA 3 phase , pre-installed 42 pole circuit breaker panel supports 3 phase 208V and single phase 208V and 120V output via Tripp Lite
Original
SUWL2120C-35 SUWL2130C-15 SUWL2130C-20 SUWL530C-10 L5-30R SUWL530C-15
Abstract: Control Relays Level Control Phase Control Launch Note - New Level & Phase Control Relays 3 , Phase Control Relays 19 Typical Phase Control Applications â'¢ They are used to monitor 3-phase , the Phase Control Relay is to monitor the presence and correct sequence of the 3 phases before , 02 / 26 / 2014 LAUNCH NOTE NEW LEVEL & PHASE CONTROL RELAYS SUMMARY â'¢ Introduction â'¢ New Level Control Relays â'¢ ENR â'¢ ENRM â'¢ New Phase Control Relays â'¢ MWS â'¢ EWS2 â Crouzet
Original
Abstract: (+5Vdc) 3 OP Output Polarity - When this input is logic "1", positive true phase outputs are , affected. OUT5 and OUT6 are always positive true. 16 R Reset input for phase 1 and phase 3 high , and phase 3. This output is used to turn on a high-side switch for phases 1 and 3. This output goes high every time phase 1 or 3 turns on. This output can only be turned off when R13 goes low. Reset , Phase 4 output 19 OUT 2 Phase 2 output 20 IN 3 Direction/ Phase 3 input - A logic "1" Anaheim Automation
Original
AA2020A aa2820 AA2020 1N4448 step motor AA2820
Abstract: /329-4700 · Fax: 781/326-8703 · www.analog.com Calibration of a 3-Phase Energy Meter Board on the ADE7754 By Etienne Moulin INTRODUCTION A 3 -phase energy meter can interface with different services like 3 - phase 4 - wire, 3 - phase 3 - wire, and 3-phase 4-wire with 2½ elements. It can also provide , calibrate a 3 -phase 4 -wire, 3 - element energy meter based on the ADE7754. It describes the software used , operation of the SPI interface. 3-PHASE ENERGY SERVICES This section presents the different 3 -phase Analog Devices
Original
ct kwh meter 3 phase energy meter circuit diagram 3 phase active power meter energy meter circuit diagram 3 phase kwh meter IC rms calculation by microcontroller AN-624 E03546
Abstract: 11 12 13 14 PHASE 1 PHASE 2 PHASE 3 PHASE 4 PHASE 5 DATA 0 DATA 1 DATA 2 DATA 3 DATA 4 , by means of the PHLD input. The data on the ADDR3-0 lines is mapped onto Phase Bits 3 to 0 and the , to the Phase Buffer Register, as shown in the tables: ADDR 3 ADDR 1 ADDR 0 Register Field 0 0 0 0 1 1 0 0 1 1 0 0 ADDR 3 ADDR 2 0 0 1 0 1 X 0 1 0 1 0 1 -Phase Bits 7 0(LSB) -Phase Bits15 8 -Phase Bits 23 16 -Phase Bits 31 24 Phase Bits 3* 0(LSB) Phase Bits Intel
Original
STEL-1175 STEL-1175 125 dw 435 STEL 1175 Out1-10 12-BITS 12-BIT
Abstract: port §2.21 Application for 3-phase 3-wire and 3-phase 4-wire.18 §2.22 energy pulse output , Provide RMS output for 3-phase current vector summation; · Provide RMS output for 3-phase voltage vector , calculating mode for 3 phase energy combined; · Adjustable meter constant; · Adjustable startup current; · , with host MCU; · Compatible with 3-phase 3-wire and 3-phase 4-wire; · Single +5V power supply; · Actions Semiconductor
Original
ATT7022A 10X10 ATT7022 IEC 62053-22 class 0.2s 62053-23 reactive energy IEC 62053-22 P44GB-80-3B4-4
Abstract: 3 3 3 2.8 1.5 1.5 1.52 1.4 1.25 1.13 0.83 1.13 0.6 9.4 6 6 2.8 2.8 2.8 5 7.4 1-Phase Bridge 1-Phase , power cycling Click below to filter the product table: 1-Phase Rectifier Bridge with Silicon Carbide Diode (Semi Fast) 1-Phase Rectifier Bridge with Superfast Recovery Diodes 1-Phase Rectifier Bridges with Standard Diodes 1-Phase Rectifier Bridges with Avalanche Diodes Remove filter Expand product table » » , 8.2 5.6 2.3 2.3 6.2 3 2.8 2.8 1.7 1.45 2.6 1.45 1.1 (K/W) 11.5 8.6 3.65 2.8 1.9 0.1 1.2 1 9.4 6 2.8 IXYS
Original
FBS16-06SC VBO20-08NO2 VBO20 VBO160-12NO7 vbo13 VBO19-12NO7 eco-pac FBS10-06SC FBE22-06N1 VBE17-06NO7 VBE26-06NO7 VBE60-06A
Abstract: multitude of applications, to meet all your requirements. 1 Supervision of Motors On 3-phase supplies , rotation, and single-phase operating 3 modes. They therefore avoid overheating faults linked to phase , On 3-phase supplies, C-Lynx control 2 relays check phase sequence and phase failure preventing a , faults linked to phase imbalance. 4 1 5 2 Temperature control 6 in lifts 3 C-Lynx temperature , 3-phase pumps, - dry run and overload protection, - 3-phase control. Level control relays (HNM Crouzet
Original
phase failure HIH Crouzet PT100 thermistor motor protection MUS80ACDC 84870700 Relays with single Changeover PT100 HT81-2 HWT81
Abstract: 115 V 1-Phase 230 V 1-Phase 230 V 3-Phase 115 V 1-Phase 230 V 1-Phase 230 V 3-Phase 230 V 1-Phase 115 V 1-Phase 230 V 1-Phase 230 V 3-Phase 230 V 1-Phase 230 V 3-Phase 230 V 1-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase Output Voltage 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase 230 V 3-Phase Motor Power kW 0.18 0.18 0.18 0.37 0.37 0.37 -
Original
ATV12H018F1 ATV12H075M2 ATV12 ATV12H037F1 ATV12H018M2 ATV12H075F1 atv312 ATV12HU22M2 ATV12H037M2 VW3A1006 ATV12HU15M2 ATV12HU40M3 ATV312
Abstract: mode settings (M1, M2, and M3) 1) 2 phase excitation drive 2) 1-2 phase excitation drive 3) W1 , circuit 3) Notes: The currently excited (driven) phase can be forcibly moved to the origin by switching , Phase B M5 1 0 0 1 Mode Circular 1 2 3 See page 10 for details on the current division ratio. 2 Circular 3 Phase A ITF02399 â'¢ RESET (Resets all parts of the , â' 1-2 phase 2W1-2 phase â' 2 phase A 0 3 28 27 25 28 B 24 8 B 5 8 B 12 SANYO Electric
Original
EN5228D STK672-050-E
Abstract: .3 3.1 Phase Noise Performance of CDC7005 LVPECL Path (Buffer Mode) .3 3.2 Phase Noise Performance of the CDC7005 With High Jitter Reference Clock and Toyocom 61.44 , .3 Phase Noise Performance of the LVPECL Path , Filter Circuit 3 Test Summary 3.1 Phase Noise Performance of CDC7005 LVPECL Path (Buffer Mode , CDC7005 WITH DIFFERENT VCXOs 3 SCAA067 Figure 3. Phase Noise Performance of the LVPECL Path Texas Instruments
Original
8656B Aeroflex PN9000 PN9000
Abstract: Phase Error vs. Frequency, Fmean = 3 GHz [1] 20 15 NORMALIZED PHASE SHIFT (degrees) 550 450 400 350 300 250 200 150 100 50 0 1.5 2 2.5 3 3.5 4 4.5 PHASE ERROR (degrees) 500 10 0.5V , Phase Shift vs. Pin @ 3 GHz 1 NORMALIZED PHASE SHIFT (degrees) 0 -1 -2 -3 -4 -5 -6 -10 0V 0.5V 6V 13V NORMALIZED PHASE SHIFT (degrees) 0 -1 -2 -3 -4 -5 -6 -10 0V 0.5V 6V 13V -8 -6 -4 , HMC928LP5E v02.1210 450° Analog Phase Shifter, 2 - 4 GHz Features Octave Bandwidth: 2 - 4 GHz Hittite Microwave
Original
Abstract: Current and Voltage Controls 3-Phase Asymmetrical Relay Type H 471 · Mains network quality and load monitoring relay · Monitors phase sequence, phase loss, phase asymmetry and phase angle · Measures asymmetry on 3-ph. voltage without neutral · Built-in adjustable timer function · , DIN/EN 50 022 · H4-housing · LED-indication for power supply and output ON · Power supply is the 3-phased measuring voltage Product Description 3-phase monitoring relay for DIN-rail mounting for phase Carlo Gavazzi
Original
H 471 156 rotation monitoring meter 156 relay phase line, phase asymmetry
Abstract: 1kHz offset VCO phase noise, Closed loop phase noise direct output (1) (2) (3) fVCO = 1579MHz, fO = 1579MHz 600kHz offset 1MHz offset 10MHz offset RMS phase error Closed loop phase noise direct output(3) 100Hz to 10MHz 1kHz offset VCO phase noise, Closed loop phase noise divide-by-2 output (1) (2) (3) fVCO , noise divide-by-2 output (3) 100Hz to 10MHz 1kHz offset VCO phase noise, Closed loop phase noise , phase error Closed loop phase noise divide-by-4 output (3) VCO gain Reference spur (2) (1) (2) (3) See Texas Instruments
Original
j 4315-0 TRF376121IRHAT TRF3761 SLWS181A TRF3761-1579 TRF3761-1700 TRF3761-1817 TRF3761-1947
Abstract: F 022-740/0XX rectangular metal case 3 phase page 56/57 F 012-401/03X rectangular plastic case 1 , case 3 phase page 58/59 F 012-01x7000 PCB Filter 1 phase page 24/25 F 022-9xx/xxx round metal case , rectangular metal case 1 phase page 50/51 F 022-748/xxx rectangular metal case 3 phase type data sheet F , F 011-227/1XX rectangular metal case 3 phase page 60/61 F 022-749/xxx rectangular metal case 3 , metal case 1 phase page 46/47 F 011-156/1XX rectangular metal case 3 phase page 60/61 F 033-3XX/000 -
OCR Scan
Eichhoff 60161 011-171/22X 022-730/0XX 011-180/0XX 044-20X/000 044-3XX/000 022-299/0XX
Abstract: Current and Voltage Controls 3-Phase Asymmetrical Control Types S 171, SY 175 · Mains network quality and load monitoring relay · Monitors phase sequence, phase loss, phase asymmetry and phase angle · Measures asymmetry on 3-ph. voltage without neutral · Built-in adjustable timer function · , Description 3-phase plug-in monitoring relay for phase sequence, phase loss, phase asymmetry and phase , - chanical The relay is ON if all 3 phaseload and motor size. In this phase voltages are within the case it Carlo Gavazzi
Original
diode sy 171 SY 185 angle phase control asymmetry sy 171 elect relay
Abstract: the introduction of Single Phase SSRs in 1970. The first of these relays were nothing more than 3 , DEFINED & DESCRIBED As previously mentioned above, a three phase SSR is essentially 3 individual single , ) 210-1550 Fax: (619) 710-8544 E-Mail: sales@crydom.com Web: www.crydom.com 3 Fig 1 ­ three phase Sine Waveform THREE PHASE RESISTIVE HEATING LOADS Three phase heater loads consist of 3 heating , power developed in a balanced three phase heater is: P = 3 x VL x IL (1) Where P is power, VL is Crydom
Original
D53TP25 diagram 3 phase heater control CWD4825 iec 62314 motor heater application note
Abstract: sample index. Table 1 shows the number of phase samples per UI for each different LEN[3:0] settings. The , number of phase samples per UI for each different LEN[3:0] settings. Table 1. Phase Samples Per UI vs , AWG phase data in Table 3 on page 4. 5) To read the ROM data from a different channel address and/or phase sample index repeat steps 3 and 4 with a different channel address or phase sample index. Note , of phase samples per UI for each LEN[3:0] setting. 2) The AWG function must be enabled for each Intel
Original
AN204 CS61880 CS61884 AN204REV1 4 channel AWG FT T1 CS61880/CS61884 CS61880/884
Showing first 20 results.